• Title/Summary/Keyword: von Mises stress

Search Result 532, Processing Time 0.039 seconds

Intra-luminal Thrombus Reduces Stress in the Aneurysm Wall: Fluid-Structure Interaction in Pulsatile Flow

  • Kim S. Y.;Kim Y. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.147-149
    • /
    • 2003
  • Using computational fluid dynamics with the fluid-structure interaction, structural effects of intra-luminal thrombus were determined in thrombosed axisymmetric abdominal aorta aneurysm (AAA) models under pulsatile flow. Four different models, varying dilatations of the aneurysm and Young's moduli of intra-luminal thrombus, were defmed. Compared with unthrombosed AAA models, both von Mises stress and radial displacements in the aneurysm wall significantly decreased. Stiffer intra-luminal thrombus reduced von Mises stress in the aneUtysm wall. The present study supported that intra-luminal thrombus might reduce wall stress in the aneurysm.

  • PDF

Analysis of stamping for the Lower control arm using Explicit code (Explicit code를 이용한 Lower control arm의 스탬핑 해석)

  • 하원필;임세영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.4
    • /
    • pp.50-58
    • /
    • 1994
  • To examine the residual stress field resulting from stamping process for the lower control arm of a car, the explicit finite element analysis is performed for the stamping process by way of the ABAQUS Explicit. The residual stress is obtained in terms of the Von Mises stress and other parameters such as equivalent plastic strain, the change of blank thickness, the final configuration of the blank and the spring back effect are also considered. Moreover, discussed is the convergence of the explicit FEM versus the punch sped and the element discretization

  • PDF

Finite Element Analysis on Contact and Work Stress of Rolled Strip (압연되는 스트립의 접촉 및 가공 응력에 대한 유한 요소 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.23-29
    • /
    • 2008
  • This study analyzes the rolled circular rod strip with radius of loom and length of 350cm by using finite element analysis. The material strength and its durability of the rolled strip can be predicted through this study. As the penetration tolerance by contact decreases, the contact rigidity of strip increases. As the contact rigidity becomes the highest at the elapsed time of 1.2 second, the contact stress becomes the lowest. On the contrary, von-Mises stress becomes highest at this time. The total deformation on strip increases from the upper part of strip at the position near to rotating roll to the lower part of strip at the position near to fixing roll.

STRESS ANALYSIS OF A HUMAN MANDIBLE UNDER VARIOUS LOADS USING FINITE ELEMENT METHOD (하악골의 부위별 충격시 발생되는 응력에 대한 유한 요소법적 연구)

  • Kim Sung-Rae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.7-22
    • /
    • 1992
  • The stress distributions on a human mandible for 18 load cases under two different boundary conditions (mouth open and closed), using the three dimensional finite element modeling were studied. Also, the expected fracture loads for each load cases were calculated by using the Von-Mises yield criterion. The model of a mandible with all teeth was composed of 2402 hexahedron elements and 3698 nodes. CAD techniques were used to analyze the 3-dimensional results. The conclusions of this study were as follows: 1. In the mouth open state, the maximum stress occured at the condyle neck; when the lateral load was exerted, the maximum stress occured at the load side condyle. 2. In the mouth closed state, when the loads were exerted on the mandibular body and chin, the maximum stress occured at the loaded area, and when the loads were exerted on the angle and ramus, the maximum stress occured at the condyle neck. 3. The expected fracture loads in each load case were calculated using the Von-Mises yield criterion, and it was confirmed that the mandible in the mouth open state was more easily fractured than that in the mouth closed state, and the expected fracture loads are lesser in the cases that load direction is parallel at mandibular plane than 45°. 4. The magnitudes of the expected fracture loads increased in the order of angle, ramus, body and chin in case of the mouth closed state, while chin, body, angle and ramus in case of the mouth open state. 5. The Von-Mises stress concentration regions analyzed by F.E.M. corresponded well with the results of clinical studies.

  • PDF

Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles

  • Choi, Sung-Hwan;Kim, Seong-Jin;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.189-198
    • /
    • 2016
  • Objective: The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. Methods: We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at $30^{\circ}$, $60^{\circ}$, and $90^{\circ}$ angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. Results: Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. Conclusions: For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Dynamic Fracture Behavior at the Spot Welding Plate (점용접된 판에서의 동적 파괴 거동)

  • Cho Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.314-318
    • /
    • 2006
  • This study is to analyze the intensity of welding part by simulating the dynamic procedure during the fracture of plates with spot welding. The upper and tower plates attached with spot welding can be seen to fall apart at the elapsed time of 0.64 ms after the upper plate is stretched from the lower plate. The maximum von Mises stress is shown at the welding part in the mid of upper and lower plates. The internal energy decreases largely and the kinetic energy increases suddenly near the elapsed time of 0.64 ms when welding part breaks down. The sliding energy decreases with step-by-step style as the time elapses. The value of this energy becomes 0 at the elapsed time of 0.2 ms and on the contrary, two plates stick each other as this value becomes a minus after this time.

  • PDF

An Impact Analysis of Adhesively-Bonded Single Lap Joint (단면 겹치기 접착 조인트의 충돌해석)

  • Lee, Ju-Won;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.172-177
    • /
    • 2010
  • This study presents an explicit dynamic analysis of an adhesively bonded single-lap joint under an impact load. The finite element software, ANSYS LS-DYNA, was used for the analysis and Von Mises stresses were obtained from the analysis. To model the adherents, solid elements were used and a rigid body was assumed for impactor modeling. Three impact heights (1 m, 5 m, and 10 m) were applied to consider different impact conditions and infinite boundary conditions were applied to the end-area of each adherent to save computational time in the analysis. In addition to investigating the stresses in the normal state, we also investigated the stresses in a damaged state (elasticity deterioration), simulated by a change in Young's modulus for 36 of the 3600 elements in the upper layer of the adhesive. The results showed that the location of damage is critical to the stress state of each layer (upper, middle, and lower).

Statistical Fracture Analysis of Turbine blade (터어빈 블레이드의 통계적 파괴 분석)

  • Choi, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • The optimum design of turbine blade at minimized fatigue life can be derived by the statistical fatigue analysis in this study, The optimum value of positions in the axes of X and Y at turbine blade can be found by design of experiments on the condition that the value of fillet radius is fixed to minimize the fatigue life. The degree of uncertainty about process at the factors in the axes of X and Y can be calculated by six sigma analysis. The optimum value of fillet radius is determined by utilizing the robust design at uncertain condition. It is concluded that maximum von Mises stress can decreased by 20% and the fatigue life can be double.

  • PDF

A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT (고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구)

  • Ko Hyun;Woo Yi-Hyung;Park Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF