• 제목/요약/키워드: volumetric frequency

검색결과 65건 처리시간 0.02초

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

DC 전해 커패시터의 고장진단 기준모델 입력을 위한 외부변수의 특성 고찰 (Characteristic Investigation of External Parameters for Fault Diagnosis Reference Model Input of DC Electrolytic Capacitor)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.186-191
    • /
    • 2012
  • DC Bus Electrolytic capacitors have been widely used in power conversion system because they can achieve high capacitance and voltage ratings with volumetric efficiency and low cost. This type of capacitors have been traditionally used for filtering, voltage smoothing, by-pass and other many applications in power conversion circuits requiring a cost effective and volumetric efficiency components. Unfortunately, electrolytic capacitors are some of the weakest components in power electronic converter. Many papers have proposed different methods or algorithms to determinate the ESR and/or capacitance C for fault diagnosis of the electrolytic capacitor. However, both ESR and C vary with frequency and temperature. Accurate knowledge of both values at the capacitors operating conditions is essential to achieve the best reference data of fault judgement. According to parameter analysis, the capacitance increases with temperature and the ESR decreases. Higher frequencies make the ESR and C to decrease. Analysis results show that the proposed electrolytic capacitor parameter estimation technique can be applied to reference signal of capacitor diagnosis systems successfully.

Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

  • Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • 제53권3호
    • /
    • pp.315-320
    • /
    • 2015
  • Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient ($k_La$), interfacial area (a) and liquid side true mass transfer coefficient ($k_L$) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of $O_2$ and chemical absorption of $CO_2$ in the column. The values of $k_La$ and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of $k_L$ increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

Food and feeding habits of Labeobarbus intermedius in the recently built Ribb Reservoir, Northwest Ethiopia

  • Minwyelet Mingist;Amare Dessie;Dagnew Mequanent;Degsera Aemro
    • Fisheries and Aquatic Sciences
    • /
    • 제26권8호
    • /
    • pp.482-490
    • /
    • 2023
  • Food and feeding habits of Labeobarbus intermedius were studied from the newly constructed Ribb Reservoir, Ethiopia during the dry (December-March) season and wet season (June-August) of 2021. The objective of the study was to determine the diet composition, seasonal variation, and ontogenetic dietary shift in the diets of the dominant cyprinid fish in Ribb Reservoir. In this study, frequency of occurrence and volumetric analysis methods were used to present the results. From a total of 203 fish samples, 132 (65%) guts contained food items. Macrophytes (29.4%), phytoplankton (27.2%), detritus (14.8%), and insects (13.6%) were the major food items in the diets volumetrically. During the dry season, L. intermedius was mainly dependent on phytoplankton (58.2%), insects (15.2%), and zooplankton (13.7%) volumetrically. Whereas, macrophytes (50.3%) and detritus (23.3%) were the dominant food items in the wet season. The frequency occurrence and volumetric contribution of the diets of L. intermedius varied significantly (χ2 test, p < 0.05) between seasons. Schoener's diet overlap index revealed a slight ontogenetic dietary shift in the diets of L. intermedius. While insects, nematodes, and zooplankton were the main diets of small-sized L. intermedius, macrophytes and detritus were ingested by large-sized L. intermedius. Generally, L. intermedius fed both plant and animal-origin food items and is considered an omnivorous feeder in Ribb Reservoir.

정전용량 탐침을 이용한 토양수분 측정장치 개발 (Developement of Soil Moisture Meter using Capacitance Probe)

  • 김기복;이남호;이종환;이승석
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.65-68
    • /
    • 2001
  • This study was conducted to develop a soil moisture meter using capacitance probe. A parallel cylinder type capacitance probe (C-probe) was fabricated The 5 MHz of crystal oscillator was constructed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model for volumetric water content having oscillation frequency changes at 5 MHz as independent variables presented the determination coefficient of 0.979 and root mean square error of $0.031\;cm^{3}cm^{3}$ for all soil samples. A prototype soil moisture meter consisting of the sample container, C-probe, oscillator, frequency counter and related signal procession units presented the correlation coefficient of 0.987 and the root mean square error of $0.032\;cm^{3}cm^{3}$ as compared with the oven drying method for unknown soil samples.

  • PDF

사양토에서의 용적수분 함량 측정을 위한 TDR 및 FDR 센서의 검증 (Verification of TDR and FDR Sensors for Volumetric Soil Water Content Measurement in Sandy Loam Soil)

  • 허승오;하상건;김정규
    • 한국토양비료학회지
    • /
    • 제42권2호
    • /
    • pp.110-116
    • /
    • 2009
  • 토양의 용적수분 함량을 현장에서 측정할 수 있어 토양 내 물 이동이나 관개관리에 효과적으로 이용할 수 있는 6종의 토양수분 센서에 대한 검정을 실시했다. TDR형태의 센서가 2종으로 토양단면측정용인 TRIME과 탐침형태인 Mini-TRASE이었으며, 4종은 FDR 형태의 센서로 토양단면 측정용인 EasyAG, EnviroSCAN, PR-1과 탐침형태의 WET-1 센서였다. 코어로 측정한 용적수분함량과 비교한 결과 TRIME은 1차 선형식의 관계에서 코어측정값과 약 2.4%의 오차를 나타냈고, Mini-TRASE는 코어 용적 수분함량과 약 1.4%의 오차를 나타냈으며, 이 오차는 실험에 사용했던 7종의 센서들 중에서 가장 작은 값이었다. EasyAG는 SF로 분석했을 때는 코어측정값과 약 2.6%의 오차를 나타냈고, 센서로 측정한 토양 수분 함량을 코어수분함량과 직접적으로 비교했을 때도 역시 약 2.6%의 오차를 나타냈다. EnviroSCAN은 SF로 분석했을 때는 코어측정값과 약 2.8%의 오차를 나타냈고, 센서로 측정한 토양수분 함량을 코어수분 함량과 직접적으로 비교했을 때는 2.6%의 오차를 나타냈다. WET-1은 센서로 측정한 값과 코어로 실측한 값 사이에 약 2.0%의 오차가 있음을 보여주고 있으며, 이것은 검정에 사용했던 FDR 센서들 중에서는 가장 작은 값이었다. PR-1은 측정시 access 튜브 내에서 방향을 조금씩 바꿀 때마다 측정값이 달리 나오는 경우가 많아 수분함량 측정횟수가 많지 않았으나 실측값과 약 4.7%의 오차를 보였다. 결론적으로 센서의 정확성을 검정하기 위해 사용된 6종의 센서 중 PR-1은 현장 측정에 문제가 있을 것으로 여겨진다.

유전율법에 따른 다공질 매질의 특성 파악을 위한 실험적 연구 (An Experimental study to estimate physical properties of porous media by a permittivity method)

  • 김만일;니시가끼마코토
    • 지질공학
    • /
    • 제13권4호
    • /
    • pp.405-418
    • /
    • 2003
  • 지반을 구성하고 있는 매질에 대한 체적함수비 및 포화 정도를 측정하는 것은 지반의 물리적 성질, 강우에 의한 지하수 함량 및 자연 사면 파괴를 이해하는데 매우 중요한 요소 중의 하나이다 이러한 지반의 요소들을 파악하기 위해 전자기파를 이용한 유전율법은 지반의 유전율상수의 특성에 따라 평가되어 지므로 다양한 분야에 적용되고 있다. 본 연구에서는 전자기파의 측정 주파수 범위 1 - 18 GHz를 사용하는 유전율 시스템인 FDR-V (Frequency domain reflectometry with vector network analyzer)를 적용하여 1 GHz와 18 GHz에서의 두 주파수 범위에 대한 표준사 (Standard sand)와 화강풍화토 (Granitic weathered soil)의 밀도, 온도 및 염분농도 의존성에 따른 유전율상수의 반응에 대해 검토하였다. 실험결과에서, 흙의 밀도 의존성은 체적함수비의 증가에 따라 유전율상수도 증가하는 것으로 측정되었으나, 이들의 밀도 의존성은 다소 낮은 것으로 판단된다. 그리고, 1 GHz 실수부 (Real part)에 대한 온도 의존성 실험에서는 온도의 증가에 따라 물과 표준사의 유전율상수는 점진적으로 감소하는 경향을 보이나 에탄올의 유전율상수는 증가하는 것으로 측정되었다. 따라서, 온도 변화에 따른 각 매질의 유전율상수는 측정 온도에 대한 영향을 고려하여야 한다. 염분농도에 따른 유전율상수의 변화는 1 GHz 허수부 (Imaginary part)에서 염분농도의 증가에 따라 유전율상수의 측정치도 함께 증가하는 것으로 나타났다. 이상과 같이, 다양한 조건하에 대한 유전율상수의 의존성들을 기초로 하여 다공질 매질의 특성을 파악하기 위한 FDR-V 시스템의 적용성을 충분히 검토하였다. 결론적으로, 본 연구에서는 1 GHz의 측정 주파수범위 내에서 다공질 매질의 염분오염도를 충분히 정량적으로 측정할 수 있는 것으로 생각된다.

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

Effect of Alternating Vacuum and Release Process on Drying Characteristics of Log Cross Section during Radio Frequency Drying

  • Xie, Dan;Lee, Nam-Ho;Chang, Yoon-Seong;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권5호
    • /
    • pp.456-465
    • /
    • 2013
  • Log cross sections of yellow poplar were dried in a radio frequency vacuum (RFV) dryer under alternating vacuum and release (AVR) process. The average moisture content (MC), temperature and vapor pressure at the volumetric center were monitored as functions of time. Three different log thicknesses (33, 60 and 75mm) were tested. The results show that the AVR process caused an increase in the drying rate when the moisture content was above fiber saturation point (FSP, about 30% MC) but that it had an inverse effect on the drying rate when the MC was below FSP. The effect of the AVR process on the drying rate decreased, and the severity of heart checks increased, with the increase in the thickness of the specimens.

원전 증기발생기 전열관 와전류검사용 보빈코일의 권선 수 변화에 대한 전기적 특성 연구 (A Study on Electrical Characteristics for Coil Winding Number Changes of Eddy Current Bobbin Coil for Steam Generator Tubes in NPPs)

  • 남민우;김철기
    • 비파괴검사학회지
    • /
    • 제32권1호
    • /
    • pp.64-70
    • /
    • 2012
  • 국내 원자력발전소 증기발생기 전열관의 건전성을 평가하기 위해서 수행되는 와전류검사의 탐촉자는 주로 두가지 종류가 사용한다. 첫 번째 와전류탐촉자는 마모와 같은 체적성 결함을 검사하기 위해 사용되는 보빈탐촉자이다. 두 번째 와전류탐촉자는 균열과 같은 비체적성 결함을 검사하기 위한 회전형 탐촉자이다. 와전류탐촉자는 검사 계통의 핵심적인 부분으로서 특정 절차서에 따라 평가가 이루어질 때 대상 시험체의 합부를 결정하는 자료를 제공하게 된다. 또한, 수집된 와전류신호의 품질은 사용되는 탐촉자의 설계특성, 기하학적 형태, 운전주파수에 따라 결정되고, 검사 결과에 미치는 영향이 크기 때문에 와전류검사 탐촉자의 선정은 특히 중요하다. 본 연구에서는 차동형 보빈탐촉자의 코일 권선 수의 변화가 탐촉자의 전기적 특성에 미치는 영향을 분석하였다. 이 결과를 이용하여 원전 증기발생기 전열관 와전류검사 보빈탐촉자를 설계하였다. 연구 결과 코일 권선 수의 변화는 전열관 형상 및 재질에 따른 검사주파수 선정에 크게 영향이 미침을 알 수 있다. 따라서 본 연구 결과를 통하여 원전 증기발생기 전열관 와전류검사 보빈탐촉자의 설계시 더욱 정밀한 코일 권선 수 설정에 토대를 구축하였다.