• Title/Summary/Keyword: volumetric frequency

Search Result 65, Processing Time 0.015 seconds

Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil (체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성)

  • Son, Young-Hwan;Bong, Tae-Ho;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.5
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

A Study on the Estimation of Diameter Distribution and Volumetric Frequency of Joint Discs Using the Least Square Method (최소자승법을 이용한 원판형 절리의 직경분포와 체적빈도 추정에 관한 연구)

  • Song Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.137-144
    • /
    • 2005
  • An estimation technique of the joint diameter distribution using the least square method is suggested. When utilizing the technique by Song and Lee, the diameter distribution would be obtained only from the trace length distribution defined in an infinite window after the trace length distribution is estimated from the contained trace length distribution. With the new technique, however, the diameter distribution can be directly obtained from the sample histogram of the contained trace lengths. Compared with the previous technique, it shows a more accurate result for small sizes of joint samples and provides the joint geometry parameter of volumetric frequency. Verification of this new technique was completed by using Monte Carlo simulations.

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

A Study on Unsaturated Permeable Properties of the Soil-Bentonite Mixtures (Soil-Bentonite 혼합토의 불포화 투수특성 연구)

  • Kim Man-il
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.123-132
    • /
    • 2005
  • This study presents the results of a laboratory investigation performed to study physical properties of soil-bentonite mixtures through the vertical permeation test and dielectric measurement test using Frequency Domain Reflectometry system for the liner of waste landfill. For the laboratory experiments, geotechnical testing was conducted on pre-mixed soil-bentonite which is consisted of standard sand, weathered granite soil and bentonite for estimating physical parameters such as a volumetric water content, void ratio and dielectric constant. In experiment results, initial soil-bentonite mixing rate has an effect of change of volumetric water content. Also change of volumetric water content of a soil-bentonite mixture is clearly detected to measure a response of dielectric constant. In order to estimate an unsaturated permeable property of soil-bentonite mixtures, equations between volumetric water content and dielectric constant were derived from this study.

A Study on Stability and Performance Characteristics in Aero - Valved Pulsating Combustion System (공기밸브형 맥동연소 시스템의 안정성 및 성능특성에 관한 연구)

  • 임광렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.11-19
    • /
    • 1993
  • The experimental study was carried out to investigate the stability and the performance characteristics of the aero-valved pulsating combustion system with maximum operating capacity of 60KW. The effect of geometry of combustion system on the stable condition, the flammability limit, the total pressure oscillation amplitude, and the operating frequency can be identified, and the maximum turn-down-ratio is obtained up to 3.3. The total pressure oscillation amplitude can be controlled by tunning the length of the air inlet pipe. The empirical equation with which the operating frequency can be approximated is proposed and the discrepancy is within 5%. The volumetric efficiency is identified to be one of the important parameters determining the upper flammability limit and the maximum value of which is approximately 22%.

  • PDF

Spectrum response of frequency range for the unsaturated soil by salinity concentration (주파수영역 스펙트럼 반응을 이용한 불포화토의 염분농도 측정에 관한 연구)

  • Kim, Man-Il;Jeong, Gyo-Cheol;Kim, Hyoung-Soo;Suk, Hee-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.389-394
    • /
    • 2005
  • In this study we carried out to evaluate the salinity concentration and volumetric water content of unsaturated soil column using frequency domain Reflectometry with vector network analyzer (FDR-V) measurement system. All of experiments were considered to the effect of temperature which ranges from l0$^{\circ}C$ to 50$^{\circ}C$ increasing the interval of l0$^{\circ}C$ controlled by the constant temperature container. From the results the responses of complex dielectric constant which consist of the real part and imaginary parts have the effect of volumetric water content and concentration of salinity at 1GHz. Use of derived equations (1) and (2) can be calculated the physical parameters such as volumetric water content and salinity concentration of unsaturated media by the responses of complex dielectric constant.

  • PDF

Analysis of Volumetric Deformation Influence Factor after Liquefaction of Sand using Cyclic Direct Simple Shear Tests (CDSS 실험을 이용한 모래의 액상화 후 체적변형 영향인자 분석)

  • Herrera, Diego;Kim, Jongkwan;Kwak, Tae-Young;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.3
    • /
    • pp.65-75
    • /
    • 2024
  • This study investigates liquefaction-induced settlement through strain-controlled tests using a cyclic direct simple shear device on clean sand specimens. By focusing on the accumulated shear strain, soil density, sample preparation method, and cyclic waveshape, this study attempts to enhance the understanding of soil behavior under seismic loading and its further deformation. Results from tests conducted on remolded samples reveal insights into excess pore water pressure development and post-liquefaction volumetric strain behavior, with denser samples exhibiting lower volumetric strains than looser samples. Similarly, the correlation between the frequency and amplitude variations of the wave and volumetric strain highlights the importance of wave characteristics in soil response, with shear strain amplitude changes, varying the volumetric strain response after reconsolidation. In addition, samples prepared under moist conditions exhibit less volumetric strain than dry-reconstituted samples. Overall, the findings of this study are expected to contribute to predictive models to evaluate liquefaction-induced settlement.

Retrieval of surface parameters in tidal flats using radar backscattering model and multi-frequency SAR data

  • Choe, Byung-Hun;Kim, Duk-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.225-234
    • /
    • 2011
  • This study proposes an inversion algorithm to extract the surface parameters, such as surface roughness and soil moisture contents, using multi-frequency SAR data. The study areas include the tidal flats of Jebu Island and the reclaimed lands of Hwaong district on the western coasts of the Korean peninsula. SAR data of three frequencies were accordingly calibrated to provide precise backscattering coefficients through absolute radiometric calibration. The root mean square (RMS) height and the correlation length, which can describe the surface roughness, were extracted from the backscattering coefficients using the inversion of the Integral Equation Method (IEM). The IEM model was appropriately modified to accommodate the environmental conditions of tidal flats. Volumetric soil moisture was also simultaneously extracted from the dielectric constant using the empirical model, which define the relations between volumetric soil moistures and dielectric constants. The results obtained from the proposed algorithm were verified with the in-situ measurements, and we confirmed that multi-frequency SAR observations combined with the surface scattering model for tidal flats can be used to quantitatively retrieve the geophysical surface parameters in tidal flats.

Optimization of a telescope movable support structure by means of Volumetric Displacements

  • Ortega, Nestor F.;Robles, Sandra I.
    • Structural Engineering and Mechanics
    • /
    • v.31 no.4
    • /
    • pp.393-405
    • /
    • 2009
  • The Purpose of this paper is to show the applicability of a methodology, developed by the authors, with which to perform the mechanical optimization of space truss structures strongly restricted. This methodology use a parameter call "Volumetric Displacement", as the Objective Function of the optimization process. This parameter considers altogether the structure weight and deformation whose effects are opposed. The Finite Element Method is employed to calculate the stress/strain state and the natural frequency of the structure through a structural linear static and natural frequency analysis. In order to show the potentially of this simple methodology, its application on a large diameter telescope structure (10 m) considering the strongly restriction that became of its use, is presented. This methodology, applied in previous works on continuous structures, such as shell roof and fluid storage vessels, is applied in this case to a space truss structure, with the purpose of generalize its applicability to different structural topology. This technique could be useful in the morphology design of deployable and retractable roof structures, whose use has extensively spread in the last years.