• 제목/요약/키워드: volume median diameter

검색결과 35건 처리시간 0.024초

과수방제기 살포입자의 직경 분포특성 (Size Distribution of Droplets Sprayed by an Orchard Sprayer)

  • 구영모;신범수;김상헌
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.431-440
    • /
    • 2001
  • Generated agri-chemical droplets by orchard sprayers are evaporated regenerated and transported along wind streams. The droplets are deposited to targets after changing their sizes, affecting the retention of droplets. An orchard sprayer, designed for spraying grapevines was studied on the spatial distribution of droplet size. The experimental variables were spray direction (0, 22.5, 45, 67.5 and 90˚), distance(2.5, 3.0 and 3.5 m) and fan speed (2,075 and 3,031 rpm). Droplet sizes were converted and analyzed from spray stains, sampled using water sensitive papers. The number median diameter (NMD) increased with an increase of the distance due to disappeared fine droplets (<50 ㎛): however, the volume median diameter (VMD) decreased due to shrunken large droplets (>100 ㎛). Fast fan speed delivered large droplets to 3.5 m, but the spatial distributions of NMD and VMD were not uniform. Slower fan speed decreased the possibility of evaporation and drift; therefore, plenty of droplets were maintained up to 3.0 m. The upward blasting distance was limited within 3 m, but the limit to the ground level was extended to 3.5 m. Concentrated wind and droplets to the ground level should be redistributed to upper canopy direction, leading more uniform deposits. High speed wind and system pressure should be avoided because of generating fine droplets, which would be disappeared and drifted away.

  • PDF

Effect of the Pore Structure of Concrete on the Compressive Strength of Concrete and Chloride Ions Diffusivity into the Concrete

  • Kim, Jin-Cheol;Paeng, Woo-Seon;Moon, Han-Young
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.345-351
    • /
    • 2003
  • The transport characteristics of deleterious ions such as chlorides depend on the pore structures of concrete and are the major factors in the durability of concrete structures in subjected to chloride attack such as in marine environments. In this paper, the effect of the pore structure on compressive strength and chloride diffusivity of concrete was investigated. Six types of concretes were tested. The pore volume of concrete containing mineral admixtures increased in the range of 3∼30nm due to micro filling effect of hydrates of the mineral admixtures. There was a good correlation between the median pore diameter, the pore volume above 50nm and compressive strength of concrete, but there was not a significant correlation between the total pore volume and compressive strength. The relationship between compressive strength and chloride diffusivity were not well correlated, however, pore volume above 50nm were closely related to the chloride diffusion coefficient.

강성 및 연성 보강을 통한 콘크리트 중앙분리대 성능 향상 분석 (Concrete Median Barrier Performance Improvement using Stiffness and Flexibility Reinforcement)

  • 김찬희;김우석;이일근;이재하
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.23-31
    • /
    • 2018
  • 최근 사용 중인 중앙분리대의 성능 등급을 뛰어넘는 사고가 발생하고 있다. 그러므로 피해를 줄이기 위해 중앙분리대의 성능 등급을 현재의 SB5-B등급보다 상향된 기준에 맞춰 개선하는 것이 필요하다. 이에 본 연구에서는 중앙분리대 충돌시험결과를 활용하여 적절한 모델을 개발 및 검증하고 강도성능이 향상된 콘크리트 중앙분리대 개발을 목표로 하였다. 중앙분리대 성능은 SB6등급으로 목표성능등급을 설정하였고, 중앙분리대의 강도성능 개선 요소로 강성보강과 연성보강의 두 가지 형태를 고려하였다. 강성보강으로는 와이어 메쉬 직경 증가, 중앙분리대 상단 부위 철판보강을 고려하였고, 연성보강을 위해서는 중앙분리대 하단에 고무패드를 설치하여 성능향상을 컴퓨터 시뮬레이션을 통해서 확인하였다. 시뮬레이션 결과, 와이어 메쉬 직경이 증가할 수록 중앙분리대의 부피 손실은 감소하였으며, 고무패드 사용시 트럭의 충격에너지를 중앙분리대의 변형에너지로 전환하여 충격흡수에 효과적인 것으로 나타났다.

저온 소성용 유리-알루미나 복합체에서 알루미나의 부피분율과 입자크기에 따른 소결 거동 (Effects of Volume Fraction & Particle Size of Alumina on Sintering Behaviors of the Glass-Alumina Composites for Low Firing Temperature)

  • 박덕훈;김봉철;김정주;박이순
    • 한국세라믹학회지
    • /
    • 제37권7호
    • /
    • pp.638-644
    • /
    • 2000
  • The sintering behaviors of the glass-alumina composites for low firing temperature were investigated as functiions of the volume fraction of alumina powder and the particle size with respect to porosity and pore shape. As the volume fraction of alumina powder was increased or the particle size of it was decreased, the sintering temperature of open pore-closing was raised. When the volume fractions of alumina which had 2.19$\mu\textrm{m}$ median diameter were increased with 20, 30, 40, and 50%, the sintering temperatures of open pore-closing were 425, 450, 475, and 500$^{\circ}C$. And when the median particle size of alumina was diminished from 2.19$\mu\textrm{m}$ to 0.38$\mu\textrm{m}$, the sintering temperature of open pore-closing was increased from 450$^{\circ}C$ to 475$^{\circ}C$. Especially, the sintering temperature, which showed maximum density, was corresponded with the stage of open pore-closing and after achieving maximum density over heating resulted in dedensification of specimen, so called, over-firing behavior.

  • PDF

Heat Transfer Characteristics of Liquid-Solid Suspension Flow in a Horizontal Pipe

  • Ku, Jae-Hyun;Cho, Hyun-Ho;Koo, Jeong-Hwan;Yoon, Suk-Goo;Lee, Jae-Keun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1159-1167
    • /
    • 2000
  • Particles in liquid-solid suspension flow might enhance or suppress the rate of heat transfer and turbulence depending on their size and concentration. The heat transfer characteristics of liquid-solid suspension in turbulent flow are not well understood due to the complexibility of interaction between solid particles and turbulence of the carrier fluid. In this study, the heat transfer coefficients of liquid-solid mixtures are investigated using a double pipe heat exchanger with suspension flows in the inner pipe. Experiments are carried out using spherical fly ash particles with mass median diameter ranging from 4 to $78{\mu}m$. The volume concentration of solids in the slurry ranged from 0 to 50% and Reynolds number ranged from 4,000 to 11,000. The heat transfer coefficient of liquid-solid suspension to water flow is found to increase with decreasing particle diameter. The heat transfer coefficient increases with particle volume concentration exhibiting the highest heat transfer enhancement at the 3% solid volume concentration and then gradually decreases. A correlation for heat transfer to liquid-solid flows in a horizontal pipe is presented.

  • PDF

활성탄의 표면 구조 변화에 따른 흡착 특성 연구 (Adsorption properties of surface - modified activated carbon)

  • 김정렬;서문원;신창호;김영호;이근회;지상운
    • 한국연초학회지
    • /
    • 제16권2호
    • /
    • pp.191-197
    • /
    • 1994
  • Relationships between surface structure and adsorption properties of smoke components were investigated in surface-modified and un-modified activated carbon filter cigarettes. Commercially available activated carbon was treated with nitric acid and hydrogen peroxide as oxidant, and their pore volume, surface structure, BET surface area, pore type and size were studied. BET surface area and pore volume were decreased by nitric acid treatment, but median pore diameter was 8.1 $\AA$, which showed better development of pore compared with that of un-modified activated carbon, 6.9 $\AA$. In case of hydrogen peroxide treatment, BET surface area and pore volume were increased. Their pore was found to be a slit type based on V-t plot analysis. Neutralization capacities for bases of different strength (NaHCO3, Na2CO3, NaOEt and NaOH) showed that the majority of the acidic surface groups are of weak acidity. Modification of the activated carbon surface led to a slight change in adsorption properties when analyzing the smoke of triple-filter cigarette with surface-modified activated carbon.

  • PDF

얼음두께를 이용한 결빙시험조건의 간접 확인기법 (Indirect Verification of the Icing Test Condition Using Ice Thickness)

  • 김유경;박남은;최기오
    • 한국항공우주학회지
    • /
    • 제46권11호
    • /
    • pp.944-951
    • /
    • 2018
  • 회전익기의 결빙운용능력이 요구될 경우 자연결빙 비행시험전 풍동시험과 인공결빙시험을 선행하면 개발기간을 단축시킬수 있다. 한국형기동헬기의 경우 인공결빙 시험을 수행하여 각 시험조건에서 방 제빙기능의 정상작동을 확인 후 자연결빙시험을 수행하였다. 인공결빙시험에서 시험조건인 액적량(LWC)과 액적 평균직경(MVD)을 확인하기 위해 정밀센서인 구름기상정보관측기(CCP)를 사용하는데 시험환경, 장비오차등의 이유로 측정치의 불확실성이 존재할 수 있어 시험조건 확인이 다방면으로 필요하다. 동체에 착빙된 얼음두께로부터 LWC를 계산하여 측정값과 비교한 결과, 시험조건을 간접적으로 검증해 볼 수 있는 효과적인 방법임을 확인하였다.

Maximum diameter versus volumetric assessment for the response evaluation of vestibular schwannomas receiving stereotactic radiotherapy

  • Choi, Youngmin;Kim, Sungmin;Kwak, Dong-Won;Lee, Hyung-Sik;Kang, Myung-Koo;Lee, Dong-Kun;Hur, Won-Joo
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: To explore the feasibility of maximum diameter as a response assessment method for vestibular schwannomas (VS) after stereotactic radiosurgery or fractionated stereotactic radiotherapy (RT), we analyzed the concordance of RT responses between maximum diameters and volumetric measurements. Materials and Methods: Forty-two patients receiving curative stereotactic radiosurgery or fractionated stereotactic RT for VS were analyzed retrospectively. Twelve patients were excluded: 4 did not receive follow-up magnetic resonance imaging (MRI) scans and 8 had initial MRI scans with a slice thickness >3 mm. The maximum diameter, tumor volume (TV), and enhanced tumor volume (ETV) were measured in each MRI study. The percent change after RT was evaluated according to the measurement methods and their concordances were calculated with the Pearson correlation. The response classifications were determined by the assessment modalities, and their agreement was analyzed with Cohen kappa statistics. Results: Median follow-up was 31.0 months (range, 3.5 to 86.5 months), and 90 follow-up MRI studies were analyzed. The percent change of maximum diameter correlated strongly with TV and ETV (r(p) = 0.85, 0.63, p = 0.000, respectively). Concordance of responses between the Response Evaluation Criteria in Solid Tumors (RECIST) using the maximum diameters and either TV or ETV were moderate (kappa = 0.58; 95% confidence interval, 0.32-0.85) or fair (kappa = 0.32; 95% confidence interval, 0.05-0.59), respectively. Conclusions: The percent changes in maximum diameter and the responses in RECIST were significantly concordant with those in the volumetric measurements. Therefore, the maximum diameters can be used for the response evaluation of VS following stereotactic RT.

Aerosol Losses in a 100L $Tedlar^{(R)}$ Bag

  • Oh, Sewon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E2호
    • /
    • pp.61-68
    • /
    • 2004
  • Aerosol losses in a 100L Tedlar$^{(R)}$ bag were investigated for the aerosols with number median diameter of 0.05 ${\mu}{\textrm}{m}$ and number concentration of 6.4 ${\times}$ 10$^4$ cm$^{-3}$ . Over a 1 hr period, loss of particles in the bag is apparent, and the volume decrease with time is significant. The number concentration, surface area, and volume concentration of the aerosols decreased to 34, 50, and 52% of the initial value in 30 min, respectively. This indicates that deposition to the walls was the main loss process for aerosols in the Tedlar$^{(R)}$ bag. Theoretical calculations showed that coagulations and deposition by diffusion and gravitational sedimentation would not change aerosol characteristics significantly, and the electrical force was the dominant loss process for particles in the Tedlar$^{(R)}$ bag over a 1 hr period.eriod.

대기 부유분진중 다환방향족 탄화수오류의 계절적 입경농도 분포 변이 (Seasonal Variation of Size Distributions of Polycyclic Aromatic Hydrocarbons in Air Particulates)

  • 정용;박성은;황만식
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.577-588
    • /
    • 1998
  • Polycyclic aromatic hydrocarbons (PAHs) are products of incomplete combustion and, in urban area atmosphere, are mainly traffic or heating in origin. Size-segregated aerosol samples were collected on the Eixth story of Shinchon on the Yonsei campus, using a high-volume cascade impactor, between August 1994 and September 1995. Ten PAHs were analyzed by GC/MSD. The size distribution of PAH-containing particulates followed approximately a log-normal relationship with the majority of PAH content associated with particles below 3.0mm. PAHs concentration in submicron particles increased during the winter months. The Mass Median Diameter (MMD) value of annual particulates in the heavy traffic area of Shinchon shows about 1.6 pm. The MMD values of air particulate in winter were the lowest values and similar to that in summer, while MMD values of seasonal PAHs were generally lower than 1.0 pm. Among the PAHs, MMD values of PAHs with the more than 5 benzen ring were averagely lower than those with 4 benzin rings. Especially MMD's of dibenzo (a, h) anthracene in winter was clearly lower than in summer. This reason may be caused by fuels used for heating. In this area, 50∼80% PAHs mass was particles smaller than 1.0mm aerodynamic diameter in size range, and the MMD values of PAHs lower than those of other country's area.

  • PDF