• 제목/요약/키워드: voltage-controlled current source

검색결과 223건 처리시간 0.024초

CURRENT-CONTROLLED PWM-RECTIFIER WITH di/dt FEEDBACK/VOLTAGE-SOURCE INVERTER WITHOUT DC LINK COMPONENTS FOR INDUCTION MOTOR DRIVE

  • Iimori, Kenichi;Shinohara, Katsuji;Muroya, Mitsuhiro;Kitanaka, Hidetoshi
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.524-528
    • /
    • 1998
  • The voltage-source inverters are normally equipped with an electrolytic capacitor in their DC link, however, the electrolytic capacitor has several disadvantages such as increasing size, limiting converter life and reliability. Therefore, several approaches for removing the DC link capacitor have been studied by the authors. This paper proposes a new voltage-source inverter without DC link components. To reduce waveform distortion of the AC source current, the current-controlled PWM-rectifier with di/dt feedback is introduced. The di/dt feedback gain and LC parameters are investigated by calculation for a 0.75kW induction motor driven by this inverter. The calculated AC source currents maintain nearly sinusoidal waveforms with a unity power factor.

  • PDF

불평형 전압 발생 시 유효전력 조절을 통한 전압형 HVDC의 DC전압 제어 방안 (Control Scheme Using Active Power Regulation for DC Voltage of VSC HVDC Under Unbalanced Voltage)

  • 박상인;허재선;문원식;김두희;김재철
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.232-239
    • /
    • 2015
  • Faced with unbalanced grid operation mode, the high voltage direct current (HVDC) based on voltage source converter (VSC) can be properly controlled by a dual current control scheme. For the modular multilevel converter (MMC) controlling the AC side current is able to limit the arm current which flows along the IGBT of submodule (SM) to rated current. However the limitation of the arm current results in leaving the control range of active power at MMC confined to below the rated capacity. As a result, limiting the arm current causes the problem that the DC side voltage of the HVDC can not be controlled to the reference value since MMC HVDC adjusts the DC side voltage through the active power. In this paper, we propose the algorithm adjusting the active powers of both MMCs to resolve the problem. The back-to-back MMC HVDC applying the algorithm is modeled by PSCAD/EMTDC to verify the algorithm.

전류오차 백터 제어방식에 의한 새로운 형태의 전류 제어 PWM 전압형 정류기 (Novel Current Controlled PWM-VSC Converter Using Current Error Vector Control)

  • 박민호;최재호
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.261-268
    • /
    • 1989
  • A novel current controlled PWM voltage source type converter and control strategy is proposed that is able to draw nearly sinusoidal current at unity power factor from three phase power lines. Current error vector control scheme is used which has two operating states : low harmonic current content state and quick current response state. The state is changed according to the current error to optimize the steady state and transient state performances. To regulate the dc oupput voltage, the magnitude of the reference current is determined by a controller dc voltage error. The ac input power factor can be controlled with unity, and even leading or lagging by adjusting the relative position of the reference current with respect to the supply voltage.

  • PDF

UPS를 고려한 계통연계 전류제어형 전압원 인버터 (Gird-interactive Current Controlled Voltage Source Inverter System with UPS)

  • 고성훈;임성훈;이수원;이성룡
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

교류측 전압 및 전류 센서가 없는 3상 Z-소스 PWM 정류기의 퍼지-PI 제어 (A Fuzzy-PI Control Scheme of the Three-Phase Z-Source PWM Rectifier without AC-Side Voltage and Current Sensors)

  • 한근우;정영국;임영철
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.767-781
    • /
    • 2013
  • In this paper, we proposes the AC input voltage and current sensorless control scheme to control the input power factor and DC output voltage of the three-phase Z-source PWM rectifier. For DC-link voltage control which is sensitive to the system parameters of the PWM rectifier, fuzzy-PI controller is used. Because the AC input voltage and current are estimated using only the DC-link voltage and current, AC input voltage and current sensors are not required. In addition, the unity input power factor and DC output voltage can be controlled. The phase-angle of the detected AC input voltage and estimated voltage, the response characteristics of the DC output voltage according to the DC voltage references, the FFT results of the estimated voltage and current, efficiency, and the response characteristics of the conventional PI controller and fuzzy-PI controller are verified by PSIM simulation.

Low Voltage Current Controlled Driving Method for AC PDP

  • Lee, Yang-Keun;Um, Jong-Sik;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.207-210
    • /
    • 2002
  • This paper presents a new driving method that can drive AC PDPs with low voltage and controlled-current for the sustaining period. The discharge current flowing into the AC PDP is limited in this method. Thus, the power consumption for the discharge is reduced and the discharge input power to output luminance efficiency is improved. Experimental results using this driving method showed that we could drive an AC PDP with a voltage source as low as 146 V and that luminous efficiency of 1.33 lm/W can be achieved.

  • PDF

One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템 (The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • 대한전기학회논문지
    • /
    • 제40권2호
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구 (A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement)

  • 손진근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

고정자전압제어 전류형 인버터에 의한 유도전동기의 속도제어 (Speed Control of Induction Motor Driven by Stator Voltage-Controlled CSI)

  • 송중호;윤태웅;김광배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.583-586
    • /
    • 1991
  • This paper presents a comprehensive study on the stability of several control schemes for the induction motor driven by current source inverters. A stator voltage-controlled current source inverter drive system without a speed sensor is investigated in order to find appropriate control schemes, which are primarily based on direct or, alternatively, indirect frequency control scheme. The overall control systems with either voltage control loop or current and voltage control loops provided in addition to each frequency control scheme are analyzed by utilizing the root locus method and simulated by computer to illustrate the validity of this analysis.

  • PDF

무손실 공진기를 가지는 전압형 PWM 컨버터의 전원전류 제어에 관한 연구 (A Study on Source Current Control of Voltage Source PWM Converter based on Lossless Resonator)

  • 허태원;신덕웅;김구형;진해중;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2040-2042
    • /
    • 1997
  • A voltage source PWM converter based on lossless resonator and a source current control system are proposed in this paper. It is proved that steady-state deviation reduces to zero from the transfer function of source current control system, owing to the lossless resonator. The system can be controlled by the feedback control only, because of no need to use a feedforward control in the proposed a source current control system. Therefore, as using lossless resonator, control system can be simply made up. Simulations are described in the case of difference between source current and source current reference.

  • PDF