• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.028초

Voltage Sag Detection Algorithm for Instantaneous Voltage Sag Corrector

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.162-170
    • /
    • 2002
  • Voltage sag detection algorithm for voltage sag corrector is proposed in this paper. To quantify the standard of voltage unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (UF). It is analyzed that MWF and UF values are given as the dc constant values even though under the voltage unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

대용량 전동기 기동시 배전계통의 순간전압강하 발생사례 분석 (An Analysis the Distribution Power System Voltage Sag Case by a High Capacity Motor Connection)

  • 박용업;이건행
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.143-148
    • /
    • 2010
  • Recently, the KEPCO is constructing the PQMS(Power Quality Monitoring System) each of the distribution line and will establish the voltage sag standard based on the long time measurement data of PQMS. The voltage sag prospect is difficult for the power system manager, however, the voltage sag forecasted is very important because the damage effect of the voltage sag is very broad. This paper describes the prospect formula of the voltage sag magnitude in the PCC(Point Common Coupling) by the starting current when the high capacity equipment is connected with the distribution line. To achieve this, this paper has proposed the sag prospect formula revision of KEPCO for the reliability improvement and the proposed formula has been applied the voltage sag real case to inspect the calculation procedure and reliability.

신재생에너지용 태양광 PCS 국내 기술기준 및 성능시험 (Domestic Technical Standards and Performance Test of Photovoltaic PCS for Renewable Energy)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.479-484
    • /
    • 2018
  • This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)-Characteristics of the utility interface. This standard tests utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1)voltage, current and frequency, 2)normal voltage operating range, 3)DC injection, 4)normal frequency operating range, 5)harmonics and 6)waveform distortion, 7)power factor of PV inverter. Therefore in this paper each test item of domestic technical standard is studied and analyzed and finally full tested by PV inverter performance function.

500 kV 개폐충격전압시스템의 비교시험 (Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV)

  • 김익수;김민규;정주영;문인욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.261-263
    • /
    • 2003
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

IEC 기반의 배전계통 플리커 관리기준 연구 (A Study on Flicker Management Standard for Distribution Power System in Korea based on IEC 61000-3-7)

  • 강문호;이흥호
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1663-1667
    • /
    • 2011
  • Voltage variation caused by large loads such as arc furnace and large motors, which use the large and instantaneous currents, can cause the voltage flicker. The flicker irritates the human's eyes and also has an adverse effect on protection device, rotating machine and electronic device etc, therefore the flicker needs to be managed effectively. Recently, the Korea power quality standard has been established on the IEC standards. This paper presents the flicker management standard for distribution power system and suggests the flicker transfer coefficients for Korea power system based on the IEC 61000-3-7.

CCVT의 2차 전압 보상 방법 (Compensation of the Secondary Voltage of a Coupling Capacitor Voltage Transformer)

  • 강용철;정태영;이지훈;장성일;김용균
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.909-914
    • /
    • 2008
  • A coupling capacitor voltage transformer(CCVT) is used in an extra or ultra high voltage system to obtain the standard low voltage signal for protection. To avoid the phase angle error between the primary and secondary voltages, a tuning reactor is connected between a capacitor and a voltage transformer. The inductance of the reactor is designed based on the power system frequency. If a fault occurs on the power system, the secondary voltage of the CCVT contains some errors due to a dc offset component and harmonic components resulting from the fault. The errors become severe in the case of a close-in fault. This paper proposes an algorithm for compensating the secondary voltage of a CCVT in the time-domain. From the measured secondary voltage of the CCVT, the secondary and primary currents are obtained; then the voltage across the capacitor and the inductor is calculated and then added to the measured secondary voltage to obtain the correct primary voltage. Test results indicate that the proposed algorithm can compensate the distorted secondary voltage of the CCVT irrespective of the fault distance, the fault inception angle, and the burden of the CCVT.

히스테리시스 특성을 고려한 CCVT 2차 전압 보상 방법 (Compensation of the secondary voltage of a coupling capacitor voltage transformer in the time-domain)

  • 강용철;정태영;김연희;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.266-267
    • /
    • 2006
  • A coupling capacitor voltage transformer (CCVT) is used in extra high voltage and ultra high voltage transmission systems to obtain the standard low voltage signal for protection and measurement. To obtain the high accuracy at the power system frequency, a tuning reactor is connected between a capacitor and a voltage transformer (VT). Thus, no distortion of the secondary voltage is generated when no fault occurs. However, when a fault occurs, the secondary voltage of the CCVT has some errors due to the transient components resulting from the fault. This paper proposes an algorithm for compensating the secondary voltage of the CCVT in the time domain. With the values of the secondary voltage of the CCVT, the secondary and the primary currents are obtained; then the voltage across the capacitor and the tuning reactoris calculated and then added to the measured secondary voltage. The proposed algorithm includes the effect of the non-linear characteristic of the VT and the influence of the ferro-resonance suppression circuit. Test results indicate that the algorithm can successfully compensate the distorted secondary voltage of the CCVT irrespective of the fault distance, the fault inception angle and the fault impedance.

  • PDF

Quantitative Evaluation of the Impact of Low-Voltage Loads due to Repetitive Voltage Sags

  • Yun Sang-Yun;Kim Jae-Chul;Moon Jong-Fil;Kang Bong-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.293-299
    • /
    • 2005
  • Automatic reclosing is a typical protection method in power distribution systems for the clearing of temporary faults. However, it has a fatal weakness in regards to voltage sags because it produces repetitive voltage sags. In this paper, we explored the repetitive impact of voltage sag due to the automatic reclosing of power distribution systems. The actual tests of low voltage loads were carried out for obtaining the susceptibility of voltage sags. The final results of the tests yielded power acceptability curves of voltage sag, and the curves transformed the 3-dimensional CBEMA (Computer Business Equipment Manufacturer Association) format. For the quantitative evaluation of the impact of repetitive voltage sags, an assessment formulation using the voltage sag contour was proposed. The proposed formulation was tested by using the voltage sag contour data of IEEE standard and the results of the test. Through the case studies, we verified that the proposed method can be effectively used to evaluate the actual impact of repetitive voltage sags.

비대칭 이중게이트 MOSFET의 상하단 산화막 두께비에 따른 전도중심에 대한 문턱전압 의존성 (Conduction Path Dependent Threshold Voltage for the Ratio of Top and Bottom Oxide Thickness of Asymmetric Double Gate MOSFET)

  • 정학기
    • 한국정보통신학회논문지
    • /
    • 제18권11호
    • /
    • pp.2709-2714
    • /
    • 2014
  • 본 연구에서는 비대칭 이중게이트 MOSFET의 상하단 게이트 산화막 두께 비에 대한 문턱전압 및 전도중심의 변화에 대하여 분석하고자한다. 비대칭 이중게이트 MOSFET는 상하단 게이트 산화막의 두께를 다르게 제작할 수 있어 문턱전압이하 영역에서 전류를 제어할 수 있는 요소가 증가하는 장점이 있다. 상하단 게이트 산화막 두께 비에 대한 문턱전압 및 전도중심을 분석하기 위하여 포아송방정식을 이용하여 해석학적 전위분포를 구하였다. 이때 전하분포는 가우스분포함수를 이용하였다. 하단게이트 전압, 채널길이, 채널두께, 이온주입범위 및 분포편차를 파라미터로 하여 문턱전압 및 전도중심의 변화를 관찰한 결과, 문턱전압은 상하단 게이트 산화막 두께 비에 따라 큰 변화를 나타냈다. 특히 채널길이 및 채널두께의 절대값보다 비에 따라 문턱전압이 변하였으며 전도중심이 상단 게이트로 이동할 때 문턱전압은 증가하였다. 또한 분포편차보단 이온주입범위에 따라 문턱전압 및 전도중심이 크게 변화하였다.

항공기 낙뢰시험 (Aircraft Lightning Test Methods)

  • 최익순;김석수;한상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1790-1792
    • /
    • 2004
  • This paper deals with the lightning test methods on aircraft. It shows lightning current and voltage test waveforms referred to SAE ARP 5412. According to this standard, to test lightning effects, mixes appropriately 5 waves for current and 4 waves for voltage depend on structure and comparison information.

  • PDF