• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.032초

점퍼장치의 동적인 횡진특성에 대한 최대횡진각의 적용 연구 (An Application of Maximum Swing Angle in Dynamic Swing Characteristics for Jumper Devices)

  • 손흥관;이은응
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.83-85
    • /
    • 1999
  • The jumper devices of overhead power transmission lines are getting increased in size with the adoptation of higher voltage and bundled conductors. Increasement of jumper devices' size results in the cost increasement. Therefore, the adoptation of prefabricated jumper device is cost effective method in T/L. This papers are mentioned about selection of proper value of standard deviation for jumper devices by dynamic swing characteristics. And we are analyzed to effects for tower scheme and weight addition.

  • PDF

전동차 실내조명의 flickering 현상에 관한 연구 (Study about flickering phenomenon of interior righting in electrical rail way train)

  • 김명룡;김원경;백광선;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.617-622
    • /
    • 2003
  • Light Flickering of the lamp(fluorescent lamp) with voltage fluctuation operates as an factor harmful to train passengers which is subjective to them. Recently, international flickering standard(IEC61000-3-3) are applied all over the world. However, there are not any study preparing for regulation about light flickering inside running train. In this study, the Flicker phenomenon is investigated from several references and also how the flickermeter is configured and defined. Flicker evaluation using it are studied.

  • PDF

5-GHz Delay-Locked Loop Using Relative Comparison Quadrature Phase Detector

  • Wang, Sung-Ho;Kim, Jung-Tae;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제2권2호
    • /
    • pp.102-105
    • /
    • 2004
  • A Quadrature phase detector for high-speed delay-locked loop is introduced. The proposed Quadrature phase detector is composed of two nor gates and it determines if the phase difference of two input clocks is 90 degrees or not. The delay locked loop circuit including the Quadrature phase detector is fabricated in a 0.18 um Standard CMOS process and it operates at 5 GHz frequency. The phase error of the delay-locked loop is maximum 2 degrees and the circuits are robust with voltage, temperature variations.

상압 분위기에서 QD 제작 및 이를 응용한 비휘발성 QD 메모리 특성 평가

  • 안강호;안진홍;정혁
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2005년도 추계 학술대회
    • /
    • pp.137-141
    • /
    • 2005
  • Quantum dot(QD) 메모리용 silicon nano-particle을 corona 방전방법에 의해 상온에서 대량 발생하는 방법을 개발하였다. Silicon QD는 SiH4 가스를 코로나 방전 영역을 통과시켜 발생시켰으며, 코로나 전압은 2.75kV를 사용하였다. SiH4 몰농도 $0.33{\times}10^{-7}\;mol/l$ 일 경우 발생된 QD입자 크기는 약 10nm이며 기하학적 표준편차(geometric standard deviation)는 1.31이었다. 이 조건에서 nonvolatile quantum dot semiconductor memory (NVQDM)를 제작하였으며, 이렇게 제작된 NVQDM flat band voltage는 1.5 volt였다.

  • PDF

이중게이트 MOSFET의 채널도핑분포의 형태에 따른 문턱전압특성분석 (Analysis of Channel Doping Profile Dependent Threshold Voltage Characteristics for Double Gate MOSFET)

  • 정학기;한지형;이재형;정동수;이종인;권오신
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.664-667
    • /
    • 2011
  • 본 연구에서는 차세대 나노소자인 DGMOSFET에서 발생하는 단채널효과 중 하나인 문턱전압특성에 대하여 분석하고자 한다. 특히 포아송방정식을 풀 때 전하분포를 가우시안 함수를 사용함으로써 보다 실험값에 가깝게 해석하였으며 이때 가우시안 함수의 변수인 이온주입범위 및 분포편차에 대하여 문턱전압의 변화를 관찰하고자 한다. 포아송방정식으로 부터 해석학적 전위분포 모델을 구하였으며 이를 이용하여 문턱전압을 구하였다. 문턱전압은 표면전위가 페르미전위의 두배가 될 때 게이트 전압으로 정의되므로 표면전위의 해석학적 모델을 구하여 문턱전압을 구하였다. 본 연구의 모델이 타당하다는 것을 입증하기 위하여 포텐셜 분포값을 수치해석학적 값과 비교하였다. 결과적으로 본 연구에서 제시한 포텐셜모델이 수치해석학적 시뮬레이션모델과 매우 잘 일치하였으며 DGMOSFET의 도핑분포 함수의 형태에 따라 문턱전압 특성을 분석하였다.

  • PDF

Web-based Measurement of ECU Signals on Vehicle using Embedded Linux

  • Choi, Kwang-Hun;Lee, Lee;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.138-142
    • /
    • 2004
  • In this paper, we present a new method for monitoring of ECU's sensor signals of vehicle. In order to measure the ECU's sensor signals, the interfaced circuit is designed to communicate ECU and the Embedded Linux is used to monitor communication result through Web the Embedded Linux system and this system is said "ECU Interface Part". In ECU Interface Part the interface circuit is designed to match voltage level between ECU and SA-1110 micro controller and interface circuit to communicate ECU according to the ISO, SAE communication protocol standard. Because Embedded Linux does not allow to access hardware directly in application level, anyone who wants to modify any low level hardware must develop device driver. To monitor ECU's sensor signals the most important thing is to match serial level between ECU and ECU Interface Part. It means to communicate correctly between two hardware we need to match voltage and signal level, and need to match baudrate. The voltage of SA-1110 is 0 ${\sim}$ +3.3V and ECU is 0 ${\sim}$ +12V and, ECU's communication Line K does multiple operation so, the interface circuit is used to match voltage and signal level. In Addition to ECU's baudrate is 10400bps, it's not standard baudrate in computer environment. So, we need to develop a device driver to control the interface circuit, and change baudrate. To monitor ECU's sensor signals through web there's a network socket program is working in Embedded Linux. It works as server program and manages user's connections and commands. Anyone who wants to monitor ECU's sensor signals he just only connect to Embedded Linux system with web browser then, Embedded Linux webserver will return the ActiveX webbased measurement software. It works in web browser and inits ECU, as a result it returns sensor signals through web. All the programs are developed with GCC(GNU C Compiler) and, webbased measurement software is developed with Borland C++ Builder.

  • PDF

IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성 (Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경;정동학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF

규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발 (Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards)

  • 고완수;이병설;최충석
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

전자식 안정기의 출력반도체 온도에 따른 주파수 가변회로 설계 (Design of Variouble Frequency Driver with Semiconductor Switch Temperature for Electronic Ballast)

  • 최명호;임성훈;오성근;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2780-2782
    • /
    • 1999
  • Many electronic ballasts for low pressure discharge lamps as fluorescent lamps are produced and commercialized. However, the electronic ballasts for high pressure lamps are now in progress to because of poor reliability and high cost of production. To obtain the confidence of electronic ballasts, it is necessary to prolong the life time of output switches. A variable frequency driver for inverter switches that can control the magnitude of output current with temperature of switches was designed and simulated. A conditions for circuit design are 22kHz : standard frequency, $100^{\circ}C$: standard temperature, $I_{peak}$ : 0.76A, and $V_{peak}$ : 184V, respectively. By simulation, as the temperature exceed a standard temperature, the frequency was increased up to 40kHz. However, the current and voltage that flow through switchs were decreased to 0.507A and 121V at $150^{\circ}C$, respectively.

  • PDF

EEPROM을 이용한 전하센서 (EEPROM Charge Sensors)

  • 이동규;김해봉;양병도;김영석;이형규
    • 한국전기전자재료학회논문지
    • /
    • 제23권8호
    • /
    • pp.605-610
    • /
    • 2010
  • The devices based on electrically erasable programmable read-only memory (EEPROM) structure are proposed for the detection of external electric charges. A large size charge contact window (CCW) extended from the floating gate is employed to immobilize external charges, and a control gate with stacked metal-insulator-metal (MIM) capacitor is adapted for a standard single polysilicon CMOS process. When positive voltage is applied to the capacitor of CCW of an n-channel EEPROM, the drain current increases due to the negative shift of its threshold voltage. Also when a pre-charged external capacitor is directly connected to the floating gate metal of CCW, the positive charges of the external capacitor make the drain current increase for n-channel, whereas the negative charges cause it to decrease. For an p-channel, however, the opposite behaviors are observed by the external voltage and charges. With the attachment of external charges to the CCW of EEPROM inverter, the characteristic inverter voltage behavior shifts from the reference curve dependent on external charge polarity. Therefore, we have demonstrated that the EEPROM inverter is capable of detecting external immobilized charges on the floating gate. and these devices are applicable to sensing the pH's or biomolecular reactions.