전압 표준용 RSFQ counter회로의 설계 (Circuit design of an RSFQ counter for voltage standard applications)

  • 남두우;김규태;김진영;강준희
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.127-130
    • /
    • 2003
  • An RSFQ (Rapid Single Flux Quantum) counter can be used as a frequency divider that was an essential part of a programmable voltage standard chip. The voltage standard chip is composed of two circuit parts, a counter and an antenna Analog signal of tens to hundreds ㎓ may be applied to a finline antenna part. This analog signal can be converted to the stream of SFQ voltage pulses by a DC/SFQ circuit. The number of voltage pulses can be reduced by 2n times when they pass through a counter that is composed of n T Flip-Flops (Toggle Flip-Flop). Such a counter can be used not only as a frequency divider, but also to build a programmable voltage standard chip. So, its application range can be telecommunication, high speed RAM, microprocessor, etc. In this work, we have used Xic, WRspice, and L-meter to design an RSFQ counter. After circuit optimization, we could obtain the bias current margins of the T Flip-Flop circuit to be above 31% Our RSFQ counter circuit designs were based on the 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

국가 고전압 표준용 직류고전압 분압기의 측정능력 향상 (Improvement of Measuring Capacity of the DC High-voltage Divider for a National High-voltage Standard)

  • 이상화;장석명;최장영
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1622-1625
    • /
    • 2014
  • The main measurement uncertainty factors in DC high-voltage dividers for a national high-voltage standard are the measurement uncertainty of low-voltage arm and the stability of a high-voltage supply. In this study, the uncertainties by the two factors are greatly improved. As a result the measurement uncertainty for the DC high-voltage divider is reduced from $16{\times}10^{-6}(k=2)$ to $8{\times}10^{-6}(k=2)$ which is at international level.

A 3.3-V Low-Power Compact Driver for Multi-Standard Physical Layer

  • Park, Joon-Young;Lee, Jin-Hee;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권1호
    • /
    • pp.36-42
    • /
    • 2007
  • A low-power compact driver for multistandard physical layer is presented. The proposed driver achieves low power and small area through the voltage-mode driver with trans-impedance configuration and the novel hybrid driver,. In the voltage-mode driver, a trans-impedance configuration alleviates the problem of limited common-mode range of error amplifiers and the area and power overhead due to pre-amplifier. For a standard with extended output swing, only current sources are added in parallel with the voltage-mode driver, which is named a 'hybrid driver'. The hybrid architecture not only increases output swing but reduces overall driver area. The overall driver occupies $0.14mm^2$. Power consumptions under 3.3-V supply are 24.5 mW for the voltage-mode driver and 44.5 mW for the hybrid driver.

실시간 전압안정도 프로그램을 이용한 제주지역 전압안정도 (Jeju area's Voltage Stability Analysis which use the Real Time Voltage Stability Analysis Program)

  • 이성우;안교상;서동완;장문종
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1387-1392
    • /
    • 2012
  • These days people use a lot of electric power, because industry advancement and a standard of living is elevated. So voltage stability analysis and control problems are very important in these days. U.S.A has already developed voltage stability analysis program, and use it on power transmission scheme such as generator overhaul, transmission line off and so on. So voltage stability analysis is more and more interested in Korea, too. In this paper, we introduce a standard theory of voltage stability analysis and real time voltage stability analysis program that use sPMU(Satellite Phasor Measurement Unit). And we also introduce the calculation result about voltage stability in Jeju power transmission system.

불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성 (SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

10의 -10승 수준에서 조셉슨 전압표준기 불확도 평가 (Uncertainty Evaluation of Josephson Voltage Standard in the level of $10^{-10}$)

  • 김규태;김문석;정연욱;김완섭;송운
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.56-61
    • /
    • 2007
  • The most recent improvement in the 10 V array system was carried out with focusing on noise reduction. We have evaluated the uncertainty of the 10 V Josephson array system after the improvement. The uncertainty evaluation of 10 V standard included a comparison with a programmable Josephson array system at 1 V. Every contribution to the measurement uncertainty was evaluated in the level of $10^{-10}$. The estimated combined uncertainty was found to be approximately $10^{-9}$ at 10 V, which was limited only by the indirect verifying method. In the near future, a direct comparison with another 10 V Josephson voltage standard is expected to be carried out to provide more accurate uncertainty evaluation for the KRISS Josephson voltage standard.

  • PDF

열전압변환기와 교류측정표준을 사용한 감쇠기 평탄도 특성 분석 기법 (Flatness Characteristics Analysis Technique of Attenuator Using Thermal Voltage Converter and AC Measurement Standard)

  • 차윤배;김부일
    • 한국정보통신학회논문지
    • /
    • 제22권2호
    • /
    • pp.330-337
    • /
    • 2018
  • 본 논문은 열전압변환기와 교류측정표준을 사용하여 10Hz에서 50MHz 대역의 감쇠기 평탄도 특성을 1kHz를 기준으로 분석하는 기법을 제안하였다. 제안된 기법은 TVC를 사용하여 측정 주파수별 감쇠기의 입력전압을 1kHz와 동일하게 공급한 후, 교류측정표준에서 지시되는 전압 변화량으로 감쇠기의 평탄도 특성분석을 수행하였다. 감쇠기 평탄도 특성분석의 결과는 1dB에서 70dB까지 최대 $866{\mu}V/V$의 불확도로 측정이 가능하며, 기존 회로망 측정방법을 사용한 2.31mV/V 보다 약 37%의 불확도가 감소된 것을 확인하였다. 향상된 감쇠기 평탄도 특성 값은 교류측정표준의 저전압 2.2V에서 2.2mV까지 주파수 평탄도 교정에 적용할 수 있다.