• Title/Summary/Keyword: voltage standard

Search Result 979, Processing Time 0.024 seconds

Analysis of Partial Discharge Pattern in XLPE/EDPM Interface Defect using the Cluster (군집화에 의한 XLPE/EPDM 계면결함 부분방전 패턴 분석)

  • Cho, Kyung-Soon;Lee, Kang-Won;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.203-204
    • /
    • 2007
  • This paper investigated the influence on partial discharge distribution of various defects at the model power cable joints interface using K-means clustering. As the result of analyzing discharge number distribution of ${\Phi}-n$ cluster, clusters shifted to $0^{\circ}\;and\;180^{\circ}$ with increasing applying voltage. It was confirmed that discharge quantity and euclidean distance between centroids were increased with applying voltage from the analyzing centroid distribution of ${\Phi}-q$ cluster. The degree of dispersion was increased with calculating standard deviation of ${\Phi}-q$ cluster centroid. The tendency both number of discharge and mean value of ${\Phi}-q$ cluster centroid were some different with defect types.

  • PDF

Improvement of Luminous Efficacy in AC PDP with Asymmetric Metal Electrode Structure (AC PDP의 효율 향상을 위한 비대칭형 금속전극구조)

  • Dong, Eun-Joo;Ok, Jung-Woo;Yoon, Cho-Rom;Lee, Hae-June;Lee, Ho-Joon;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.660-667
    • /
    • 2008
  • To improve the luminous efficacy of PDPs, an AC PDP with new metal electrode structure is suggested. Operating voltage margin, power consumption, luminance, luminous efficacy, addressing jitter and ICCD image of test panel with proposed structure are measured, to compared with performances of the conventional ITO structure and proposed structures. To enhance luminous efficacy, we designed new structure which have asymmetric metal electrode structure. The experimental results show that the suggested structure shows luminance to maximum 89% and luminous efficacy to maximum 107% compared with conventional ITO standard structure. In addition, proposed structures with asymmetric electrode show low power consumption by $2{\sim}3%$, high luminance by $5{\sim}7%$, and high luminous efficacy by $2{\sim}3%$ compared with proposed symmetric electrode structures.

Partial Discharge Distribution Analysis on Interlace Defects of Cable Joint using K-means Clustering (K-means 클러스터링을 이용한 케이블 접속재 계면결함의 부분방전 분포 해석)

  • Cho, Kyung-Soon;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.959-964
    • /
    • 2007
  • To investigate the influence of partial discharge(PD) distribution characteristics due to various defects on the power cable joints interface, we used the K-means clustering method. As the result of PD number(n) distribution analyzing on $\Phi-n$ graph, the phase angle($\Phi$) of cluster centroid shifted to $0^{\circ}\;and\;180^{\circ}$ increasing with applying voltage. It was confirmed that the PD quantify(q) and euclidean distance of centroid were increased with applying voltage from the centroid distribution analyzing of $\Phi-q$ plane. The dispersion degree was increased with calculated standard deviation of the $\Phi-q$ cluster centroid. The PD number and mean value on $\Phi-q$ graph were some different by electric field concentration with defect types.

to examine of management standard by the harmonics measured and analyzed in 22.9kV Power lines (22.9kV 수용가 전력계통별 고조파 발생실태 및 관리기준 조사분석)

  • Lee Eun Chun;Shin Gang Wook;Hong Sung Taek;Hong Young Jae;Park Young Chun;Lim Jae Il
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.270-272
    • /
    • 2004
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occurred occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

A Study of Modeling Optimization Scheme for application of Power System Voltage & Compensating Phase Modifying Equipment (계통전압 및 보상용 조상설비 적용 검토시 S.C 모델링 최적화 방안 연구)

  • Yun Ki Seob;Baik Seung Do;Kim Ju Seong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.192-194
    • /
    • 2004
  • At present, application of PSS/E input data for power flow , stability and fault analysis consist of only 154kV and over data(except 22.9kV data). 22.9kV(5.C) Static Condenser is in operation and installation at 22.9kV Bus of 154kV Substation. however, we assume that 22.9kV 5.C install at 154kV Bus. so, we need to study and search about critical limit for 154kV Bus standard operating Voltage according to 22.9kV 5.C Modeling Site by PSS/E Ver28

  • PDF

Comprehension of the Response Time in a Microbial BOD Sensor(II)

  • Sohn, Moo-Jeong;Hong, Dae-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.666-668
    • /
    • 1993
  • A microbial BOD sensor using immobilized Hansenula anomala was prepared for the estimation of BOD. The sensor voltage was increased with time and increasing concentration of GGA when it was inserted in a sample solution. A linear relationship was obtained with a correlation coefficient, 0.998 between the concentration of standard GGA solutions and dV/dt by using the initial change of voltage, in which the response time was 20 min. It could be concluded that the oxidation of GGA conformed to a first-order kinetics. Therefore, the good linearities were also observed at various times. This sensor showed the best linearity at 30 min.

Effects of Transfer Gate on the Photocurrent Characteristics of Gate/Body-Tied MOSFET-Type Photodetector

  • Jang, Juneyoung;Seo, Sang-Ho;Kong, Jaesung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.12-15
    • /
    • 2022
  • In this study, we studied the effects of transfer gate on the photocurrent characteristics of gate/body-tied (GBT) metal-oxide semiconductor field-effect transistor (MOSFET)-type photodetector. The GBT MOSFET-type photodetector has high sensitivity owing to the amplifying characteristic of the photocurrent generated by light. The transfer gate controls the flow of photocurrent by controlling the barrier to holes, thereby varying the sensitivity of the photodetector. The presented GBT MOSFET-type photodetector using a built-in transfer gate was designed and fabricated via a 0.18-㎛ standard complementary metal-oxide-semiconductor (CMOS) process. Using a laser diode, the photocurrent was measured according to the wavelength of the incident light by adjusting the voltage of the transfer gate. Variable sensitivity of the presented GBT MOSFET-type photodetector was experimentally confirmed by adjusting the transfer gate voltage in the range of 405 nm to 980 nm.

A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis (방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구)

  • Byeon, Junghwan;Choi, Sang-won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

Sparkover Voltage Estimation of Standard Sphere Gaps for Negative Polarity by Calculation of Ionization Index

  • Nishikori, Yasuo;Kojima, Soji;Kouno, Teruya
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.45-50
    • /
    • 2004
  • The field utilization factor (equation omitted) (the mean electric field / the maximum electric field) of standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. n changes mainly with g/r and slightly with 1$_1$, 1$_2$ and 1, where D=2r is the sphere diameter, g is the gap length, 1$_1$ and 1$_2$, respectively, are the lengths of the upper and lower shank, and t is the shank diameter. Generally, (equation omitted) increases as 1$_1$,1$_2$ and t each becomes larger. IEC standard 60052(2002) limits t$\leq$0.2D 1$_1$$\geq$1D and prescribes A=1$_2$+D+g where A is the height of the spark point on the upper sphere. Therefore, (equation omitted) is the largest when A=9D and the smallest when A=3D. The simple equation of a straight line, (equation omitted)=1- (g/3r), can generally be used as a representative value of (equation omitted) for a wide variety of sphere diameters that are permitted by the IEC standard. The maximum electric field E$_{m}$ at sparkover of standard air gaps has also been calculated by the relation E$_{m}$=V/(equation omitted)g). E$_{m}$ describes a U-curve for g/r, up to the sphere diameter of 1 m. Moreover, for 1.5-m and 2-m diameters and especially .for negative polarity, sparkover voltages have been calculated by integration of the ionization index.index.

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF