• 제목/요약/키워드: voltage sags

검색결과 102건 처리시간 0.029초

부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법 (Power Quality Index and Cost based on Load-Voltage Characteristics)

  • 이근준
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.213-218
    • /
    • 2003
  • In front of the opening of electric distribution market in 2004, it is indispensable to have a proper estimation of power quality index and rower quality cost calculation mechanism which are indispensable to stabilize highly industrialized society and to vitalize the Investment lot electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and Interruptions which make electric load in unstable operation. This paper suggests power quality index and power quality cost which translate various kinds of voltage records into bus load drop index(BLDI) and bus power quality cost(BPQC) based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power Quality index and costs for utilities and customers requirements.

지리 정보를 이용한 순간 전압 품질 해석 시뮬레이터 (Voltage Sag Simulator with Geographical Information)

  • 김기현;박창현;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.213-216
    • /
    • 2003
  • A voltage sag is a short-duration reduction in rms voltage, and utilities have been faced with rising numbers of complaints about the quality of power due to voltage sags. In this paper, vulnerable areas of voltage sag are determined using representative loads at the buses. The CBEMA curves of the representative loads are used to determine whether the bus is vulnerable or not. Also, the ares are displayed with geographical information in order to help operators understand the situation going on easily. The proposed simulator is applied to Jeju power system to show its capabilities.

  • PDF

PQR 순시전력이론에 의한 Dynamic Voltage Restorer의 제어기 설계 I -기준전압 파형의 발생 (Controller Design for Dynamic Voltage Restorers by use of PQR Power Theory I - Reference Wave Generation)

  • 김효성;이상준;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.398-403
    • /
    • 2003
  • Dynamic Voltage Restorers (DVR)s are known as the best effective and economic means to compensate for voltage sags and swells [1]-[11]. This paper proposes a novel method to generate reference voltages synchronized with the grid whether the line voltages are distorted by a fault or not. The proposed reference wave generator (RWC) looks for the original wave forms from the corrupted line voltages and synthesizes the expected positive sequence reference waves for DVRs. There is no transient problem on the generated reference waves when the line voltages are distorted by the fault.

  • PDF

순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation)

  • 이승요
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.739-743
    • /
    • 2000
  • With significant development of power electronics technology the proliferation of nonlinear loads such as such as static power converters has deteriorated power quality in power transmission distribution systems. Notably voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problem in many systems Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. Int his paper proposed 3 phase hybrid series active power filter is not only for harmonic compensation but also for harmonic isolation between supply and load and for voltage regulation and imbalance compensation Through computer simulations we have verified the effectiveness of the proposed system.

  • PDF

삼상 변압기와 유도전동기에서의 전압 sag에 의한 들입 전류 분석 (Analysis of inrush current caused by voltage sag in three-phase transformer and induction motor)

  • 김경남;안선주;정일엽;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2005
  • This paper studies the effects caused by symmetrical and unsymmetrical voltage sags on three-phase transformer and induction machine. The voltage sag on transformer and induction machine gives rise to inrush current. This inrush current makes sag more severe. These effects depend or many elements such as sag magnitude and duration, type of sag, and fault and recovery voltage instants.

  • PDF

고품질 정밀형 Voltage sag 보상기 설계 및 해석 (Design and Analysis of the High Quality Accuracy Voltage sag Compensator)

  • 오세호;최현영;박정균;류형선;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.356-358
    • /
    • 2001
  • Voltage sags are known as a serious problem causing mal-operation of equipment, process controllers and adjustable-speed drives. We understand problems of the voltage sag that have a bad effect to the load and then we design for a new model of the compensator. We accomplished system modeling for both sensorless part and sensing part, and compare the merits and demerits of both.

  • PDF

PQR 순시전력이론에 의한 동적전압보상기의 기준파 발생기 (The Reference Wave Generator for Dynamic Voltage Restorers by use of PQR Instantaneous Power Theory)

  • 김효성;이상준;설승기
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.435-441
    • /
    • 2003
  • 순시전압강하보상기 (DVR)는 순시전압강하 및 상승을 보상하기 위한 가장 효과적이고 경제적인 수단으로 알려져 있다. 본 논문은 계통의 전압이 사고에 의해서 심하게 왜곡되는 경우에서도 계통과 동기된 정현적인 기준파를 생성하는 방법을 제시한다. 제안된 기준파발생기 (RWG)는 사고로 왜곡된 전압으로부터 원래의 정현적인 파형을 추출하고 정상 성분만의 전압을 합성하여 DVR의 제어에 사용하도록 한다. 전윈 전압의 사고 순간에도 RWG는 과도적인 문제가 없는 안정된 정현 파형을 출력한다.

부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법 (Bus Power Quality Index and Cost based on Load-Voltage Characteristics)

  • 이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-14
    • /
    • 2002
  • In front of the opening of electric distribution market in 2004. it is indispensable to have a proper estimation of power quality index and power quality cost calculation mechanism are indispensable to stabilize highly industrialized society and to vitalize the investment for electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and interruptions which make electric load in unstable operation. This paper suggests power quality index(LDI) and power quality cost(LDC) which translate various kinds of voltage records into load drop index and cost based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power quality index and costs for utilities and customers requirements.

  • PDF

다수의 민감 부하를 고려한 신속한 가혹지역 계산 방법 (Fast Method to Calculate an Area of Severity Considering Multiple Sensitive Loads)

  • 박상호;이계병;김건중;박창현
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1641-1646
    • /
    • 2017
  • This paper presents a fast method to identify an area of severity which is a network area leading to voltage sags at multiple sensitive load points, simultaneously. To assess voltage sag performance considering various sensitive loads, it is need to determine an area of severity for the load points. The area of severity can be calculated by overlapping areas of vulnerability for each sensitive load. However, as the number of sensitive loads increases, computational complexity and time for determining an area of severity are highly increased. In this paper, an efficient scheme based on line division is described. The proposed method is useful for identifying an area of severity and assessing voltage sag performance considering multiple loads together.

Design of a Converter with Anti-blinking Circuitry for T5 LED Indirect Lighting

  • Woo-young, Kim;Quoc Cuong Nguyen;Seong-Kweon Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.103-111
    • /
    • 2024
  • We address the problematic issue of blinking in residential LED lighting systems-a phenomenon that has recently become a significant concern due to voltage sags caused by high-power household appliances. To combat this, we developed a two-stage LED converter with integrated anti-blinking circuitry, specifically designed for T5 LED indirect lighting fixtures. The first stage employs a Power Factor Correction (PFC) boost circuit to enhance voltage stability by aligning the voltage and current phases, thereby minimizing power losses. The second stage, a meticulously engineered DC-DC buck converter, ensures stable lighting despite electrical fluctuations. Rigorous testing has confirmed our converter's efficacy in maintaining consistent light output without blinking, thereby substantially improving user comfort and adhering to strict standards for harmonic distortion and electromagnetic compatibility. Our breakthrough provides a robust solution to a pressing issue, marking a significant advancement in LED lighting technology.