• 제목/요약/키워드: voltage gating

검색결과 73건 처리시간 0.033초

금이 도우핑된 P-I-N 다이오드의 전기적 및 광학적 스위칭 특성 (Electrical and Optical Switching Characteristics of Gold-Doped P-I-N Diodes)

  • 민남기;하동식;이성재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1547-1549
    • /
    • 1996
  • The electrical and optical switching characteristics of gold-doped silicon p-i-n diodes have been investigated. The device shows a dark switching voltage of about 500 V. The switching voltage decreases rapidly when the illumination level is increased. The differential sensitivity of optical gating over linear region is $d(V_{Th}/V_{Tho})/dP_{Ph}$=0.25/uW. The turn-on delay time and the turn-on rise time decrease with increasing optical pulse power. The turn-off delay and the fall time are negligible.

  • PDF

The Substates with Mutants That Negatively Charged Aspartate in Position 172 Was Replaced with Positive Charge in Murine Inward Rectifier Potassium Channel (Murine Kir2.1)

  • So, I.;Ashmole, I.;Stanfield, P.R.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권5호
    • /
    • pp.267-273
    • /
    • 2003
  • We have investigated the effect on inducing substate(s) of positively charged residues replaced in position 172 of the second transmembrane domain in murine inward rectifier potassium channels, formed by stable or transient transfection of Kir2.1 gene in MEL or CHO cells. Single channel recordings were obtained from either cell-attached patches or inside-out patches excised into solution containing 10 mM EDTA to rule out the effect of $Mg^{2+}$ on the channel gating. The substate(s) could be recorded with all mutants D172H, D172K and D172R. The unitary current-voltage (I-V) relation was not linear with D172H at $pH_i$ 6.3, whereas the unitary I-V relation was linear at $pH_i$ 8.0. The relative occupancy at $S_{LC}$ was increased from 0.018 at $pH_i$ 8.0 to 0.45 at $pH_i$ 5.5. In H-N dimer, that was increased from 0.016 at $pH_i$ 8.0 to 0.23 at $pH_i$ 5.5. The larger the size of the side chain or $pK_a$ with mutants (D172H, D172K and D172R), the more frequent the transitions between the fully open state and substate within an opening. The conductance of the substate also depended upon the pKa or the size of the side chain. The relative occupancy at substate $S_{LC}$ with monomer D172K (0.50) was less than that in K-H dimer (0.83). However, the relative occupancy at substate with D172R (0.79) was similar to that with R-N dimer (0.82). In the contrary to ROMK1, positive charge as well as negative charge in position 172 can induce the substate rather than block the pore in murine Kir2.1. The single channel properties of the mutant, that is, unitary I-V relation, the voltage dependence of the mean open time and relative occupancy of the substates and the increased latency to the first opening, explain the intrinsic gating observed in whole cell recordings.

새로운 방식의 PFC Single Stage Full Bridge AC/DC Converter (New Single Stage PFC Full Bridge AC/DC Converter)

  • 임창섭;권순걸
    • 융합신호처리학회논문지
    • /
    • 제3권3호
    • /
    • pp.70-75
    • /
    • 2002
  • 본 논문은 새로운 단일 전력단 역률보상 풀 브리지 컨버터를 제안하였다. 제안된 컨버터는 역률보상을 위하여 앞단에 2개의 인덕터, 2개의 다이오드, 2개의 자성결합 변압기를 가진 2VS 풀브리지 DC/DC 컨버터로 구성되어 있다. 이러한 구성방법에 의해 전력은 전원에서 분리되고, 안정된 직류출력전압을 얻을 수 있다. 이 토폴로지에서 주소자의 전압스트레스는 영전압스위칭에 의해서 감소되며, 또한 제안된 컨버터는 능동 역률보정 스위치와 제어 및 게이팅 보드와 같은 보조회로가 필요치 않게되어 규격과 단가를 낮출 수 있을 뿐 아니라 효율을 증가시킬 수 있다.

  • PDF

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

Improved Sliding Mode Controller for Shunt Active Power Filter

  • Sahara, Attia;Kessal, Abdelhalim;Rahmani, Lazhar;Gaubert, Jean-Paul
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.662-669
    • /
    • 2016
  • In this work, nonlinear control of a three-phase shunt active power filter (SAPF) has been studied and compared to classical control based on proportional integral regulator. The control strategy is based on the direct current method using sliding mode control (SMC), where the aim is to regulate the average voltage across the dc bus of the inverter. Details are given for the control algorithm; the controller is comprised of a current loop which utilizes a hysteresis controller to generate the gating signals for the switching devices, and a nonlinear controller based on SMC law which is different from classical laws based on error between reference and measured output voltage of the inverter. Sliding surface applied in this work contains the whole of state variables, in order to ensure full control of the system behavior in the presence of disturbances that affect the supply source, the load parameters or the reference value. The designed controller offers advantage that it can gives the improvement of dynamic and static performances in cases of large disturbances. A comparison of the effects of PI control and SMC on the APF response in steady stat, under line variations, load variations, and different component variations is performed.

Direct Duty Ratio Pulse Width Modulation Method for Matrix Converters

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon;Kim, Kyoung-Min;Lee, Buhm;Park, Jun-Hyub
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.660-669
    • /
    • 2008
  • This paper presents a new carrier based pulse-width modulation (PWM) method for matrix converters. By using the concept of average over one switching period, the modulation algorithm and the required equations are derived to synthesize the desired output voltage and to achieve the controlled input power factor. The proposed method uses a continuous carrier and the predetermined duty ratio signals to directly generate the gating signals and, thus, is referred to as "direct duty ratio PWM (DDPWM)". The feasibility and validity of the proposed method were verified by simulation and experiment.

반도체(半導體) DI switching소자(素子)의 전기적(電氣的) 특성(特性) (Electrical Characteristics of Semiconductor DI Switching Devices)

  • 정세진;임경문;성만영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.110-114
    • /
    • 1990
  • Double Injection Switching Devices consist of $P^+$ and $n^+$ contact separated by a near intrinsic Semiconductor region containing deep trap. A V-Groove Double Injection Switching Devices were proposed for high voltage performance and Optical gating scheme. The experimental result to demonstrate the feasibility of these devices (Planar type, V-Groove type, Injection Gate mode, Optical Gate mode) for practical application are described.

  • PDF

시평균화방법을 이용한 PWM 신호발생에 관한 연구 (A Study on the PWM Generation using Time Average Model)

  • 홍순욱;차재덕;조규복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1088-1091
    • /
    • 1992
  • Programmed PWM(Pulse Width Modulated) generation techniques eliminating several low order harmonics have been widely used in the inverter circuit which produces minimum current ripple, reduced torque pulsation and thereby improves overall system performance. However, the applications of the programmed PWM technique are limited to CVCF(Constant Voltage Constant Frequency) applications and various motor drives. Although the programmed PWM produces a lower harmonic distorted waveform than the carrier modulated PWM, real-time programming is not possible because of the complicated calculation required for the gating signal. In this paper, a new programmed PWM technique named TAM (time averaging model) is developed to compensate for the demerits of the conventional programmed PWM technique with moderate harmonic distortion. Computer simulations are performed to verify the performance of the proposed algorithm.

  • PDF

운전중인 변압기의 부분방전 측정기법 적용 (Application of the Partial Discharge Measuring Method in Operating Transformer)

  • 권동진;최인혁;정길조
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

온라인 변압기 부분방전 측정기법 (On Line Partial Discharge Measurement Method for Transformer)

  • 권동진;최인혁;송일근;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF