• 제목/요약/키워드: voltage fluctuation

검색결과 278건 처리시간 0.026초

Fuzzy Based Approach for the Safety Assessment of Human Body under ELF EM field Considering Power System States

  • Kim, Sang C.;Kim, Doo H.
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.117-122
    • /
    • 1997
  • This paper presents a study on the fuzzy based approach for the safety assessment of human body under ELF electric and magnetic(EM) field considering power system states. The analysis of ELF EM field based on quasi-static method is introduced. UP to the present, the analysis of ELF EM field has been conducted with the consideration of one transmission line, or a power line model only In this paper, however, the power system is included to model the expected and/or unexpected uncertainty caused by the load fluctuation and parameter changes and the states are classified into two types, normal state resulting from normal operation and emergency state from outages. In order to analyze the uncertainty in the normal state, the Monte Carlo Simulation, a statistic approach was introduced and line current and bus voltage distribution are calculated by a contingency analysis method, in the emergency state. To access the safety of human body, the approach based on fuzzy linguistic variable is adopted to overcome the shortcomings of the assessment by a crisp set concept. In order to validate the usefulness of the approach suggested herein, the case study using a sample system with 765(kV) was done. The results are presented and discussed.

  • PDF

IEC 국제표준에 따른 계통연계형 풍력터빈 발전기계통의 전력품질 측정방법에 관한 심화연구 (A Synthetical Study on Power Quality Measurement of Grid-Connected Wind Turbine Generating System based on the IEC International Standards)

  • 조수환
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.197-204
    • /
    • 2014
  • As more and more renewable energy resources are connected into the existing power system and their generation capacities are increasing, the need for regulations to minimize their impacts on the power grid is increasingly growing. And minimizing the irregular impacts made by grid-connected wind generators is important, since the output power generated by renewable energy resources can be changed easily by the weather condition and surrounding environment. In South Korea, an operational technical standard for distributed generation is used as a regulation, in which renewable energy sources including wind power are considered as a kind of distributed generation. In this paper, an international standard, IEC 61400-21, for the grid-connected wind turbine generating system(WTGS) will be introduced and a comprehensive and detailed review on the measuring methods of power quality characteristic parameters for WTGS based on the related IEC standards will be presented. Additionally, some prerequisites for applying the international standards to KEPCO system will be proposed.

Power Factor Improvement of Distribution System with EV Chargers based on SMC Method for SVC

  • Farkoush, Saeid Gholami;Kim, Chang-Hwan;Jung, Ho-Chul;Lee, Sanghyuk;Theera-Umpon, Nipon;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1340-1347
    • /
    • 2017
  • Utilization of Electric Vehicles (EVs) have been growing popularity in recent years due to increment in fuel price and lack of natural resources. Random unexpected charging by home EV charger in distribution is predicted in the future. The power quality problems such as fluctuation of power factor in a residential distribution network was explored with random EV chargers. This paper proposes a high-performance nonlinear sliding mode controller (SMC) for an EV charging system to compensate voltage distortions and to enhance the power factor against the unbalanced EV chargers. For the verification of the proposed scheme, MATLAB-Simulink simulations are performed on 22.9-kV grid. The results show that the proposed scheme can improve the power factor of a smart grid due to the EV chargers on the grid.

DEVELOPMENT OF AGRICULTURAL HYDRAULIC ROBOT(Part II) - Dynamic Characteristic of Hydraulic System

  • Mikio, Umeda;Michihisa, Iida;Kiyoshi, Namikawa
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.830-839
    • /
    • 1993
  • Agricultural hydraulic robot which was reported in Part Ⅰ had been developed . The robot satisfied performance to intend before development. For actual use, however, it have been necessary to reduce manipulator weigh and to simplify construction of hydraulic control valve. Then, working stress of manipulator link and pressure fluctuation of hydraulic circuit were measured. Step and frequency response tests were done subject to amplitude of reference voltage of 0.1 , 0.3 , 0.5 and 1.0v. and delivery pressure of 3.5 and 5.0MPa. Working stress were about 25% comparing with fatigue strength, Thus, mass of manipulator might be reduce to 30 %. In hydraulic control system, virtual natural frequency of 6.5Hz is produced from the combination of drain passage area shortage of servovalve. Further , because of passage area shortage , working pressure at both side of cylinder was acted on. This phenomenon prevent utilize effectively engine power. Then, control valve for new model was p oposed.

  • PDF

Molybdenum and Cobalt Silicide Field Emitter Arrays

  • Lee, Jong-Duk;Shim, Byung-Chang;Park, Byung-Gook;Kwon, Sang-Jik
    • Journal of Information Display
    • /
    • 제1권1호
    • /
    • pp.63-69
    • /
    • 2000
  • In order to improve both the level and the stability of electron emission, Mo and Co silicides were formed from Mo mono-layer and Ti/Co bi-layers on single crystal silicon field emitter arrays (FEAs), respectively. Using the slope of Fowler-Nordheim curve and tip radius measured from scanning electron microscopy (SEM), the effective work function of Mo and Co silicide FEAs were calculated to be 3.13 eV and 2.56 eV, respectively. Compared with silicon field emitters, Mo and Co silicide exhibited 10 and 34 times higher maximum emission current, 10 V and 46 V higher device failure voltage, and 6.1 and 4.8 times lower current fluctuation, respectively. Moreover, the emission currents of the silicide FEAs depending on vacuum level were almost the same in the range of $10^{-9}{\sim}10^{-6}$ torr. This result shows that silicide is robust in terms of anode current degradation due to the absorption of air molecules.

  • PDF

PV System 기반 ESS의 최적운전을 위한 설계 및 제어 특성에 관한 연구 (A Study on the Design and Control Characteristics for Optimum Operation of the PV System-based ESS)

  • 차인수;박종복;정경환
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.19-30
    • /
    • 2016
  • In this study, realize voltage regulation $220Vac{\pm}10%$ or less, frequency fluctuation $60Hz{\pm}1%$ or less over the independent operation and grid-connected operation technologies for power stabilization relates to the ESS designed and manufactured in conjunction with solar installations and solar to compensate the output reduction due to the polarization of the solar module through the polarization prevention technology for preventing the optical module efficiency is lowered, in conjunction with the BMS inverter efficiency was more than 92%, more than 90% of the charging efficiency to the target. This study was designed in conjunction with the ESS solar power plants, grid-connected operation and independent operation, Peak-Cut, it can stabilize the grid via the Peak-Shifting operation

전동차용 IGBT형 190kVA 보조전원장치 개발 (The Development of IGBT Type 190kVA Static Inverter for Electric Car)

  • 김종규;박건태;정기찬;김두식;서광덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.634-637
    • /
    • 1997
  • This paper is on the research and development of new SIV(Static Inverter) using IGBT(Insulated Gate Bipolar Transistor) semiconductor for a wide range of electric railway applications. For the simplification and higher controllability, the direct PWM control method with 3level inverter topology was adopted. In the new SIV system, the cost as well as bulk and weight was appreciably reduced about 40% lower than those of conventional SIV, the electrical efficiency was increased above 95% and the audible noise level was less than 65dB. In addition, the THD(Total Harmonic Distortion) factor was below 5% and the voltage fluctuation on a transient state was below 10%.

  • PDF

저속영역에서 속도검출기가 없는 유도전동기의 강인성 적응제어 시스템 (Robust Adaptive Control System for Induction Motor Drive Without Speed Sensor at Low Speed)

  • 김민회
    • 한국산업융합학회 논문집
    • /
    • 제2권2호
    • /
    • pp.91-102
    • /
    • 1999
  • The paper describes a robust adaptive control algorithm for induction motor drive without speed sensor at low speed range. The control algorithm use only current sensors in a space vector pulse width modulation within loop control with rotor speed estimation and voltage source inverter. On-line rotor speed estimation is based on utilizing parallel model reference adaptive control system. MRAC of the modified flux model for flux and rotor speed estimator uses dual-adaptation mechanism, ${\omega}_r$ and ${\omega}_e$ scheme. The estimated flux components in the model can be compensated from the effects of offset errors on pure integrals. It can be compensated to the parameter variations and torque fluctuation with speed estimation in less then 10 rad/sec. In a simulation, the proposed induction motor control algorithm without speed sensor at very low speed range are shown to operate very well in spite of variable rotor time constant and fluctuating load without change the controller parameters. The suggested control strategy and estimation method have been validated by simulation study, and it proposed the designed system for the implementation using TI320C31 DSP/ASIC controller.

  • PDF

전력계통의 사고전류 저감 설비별 특성 비교 (Comparison of Fault Current Limiting Characteristics According to Facility in Power System)

  • 박형민;최효상;조용선;임성훈;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

DLC-coated Si-tip FEA 제조에 있어서 기판 상에 경사-회전 증착된 Al 희생층을 이용한 Gate누설 전류의 감소 (Decrease of Gate Leakage Current by Employing Al Sacrificial Layer Deposited on a Tilted and Rotated Substrate in the DLC-coated Si-tip FEA Fabrication)

  • 주병권;김영조
    • 마이크로전자및패키징학회지
    • /
    • 제7권3호
    • /
    • pp.27-29
    • /
    • 2000
  • Lift-off를 이용한 DLC-coated Si-tip FEA 제조에 있어서 gate 절연막의 측면에 DLC가 coating되는 것을 방지하기 위해 기판 상에 Al 희생층을 경사-회전 증착한 뒤 DLC를 coating하고, 다음으로 희생층을 식각하여 tip 이외의 DLC를 제거하는 방법을 제안하였다. 이러한 Al희생층을 이용한 lift-off공정에 의해 제조된 DLC-coated Si-tip FEA의 전류전압 특성과 전류 표동 특성을 조사하였으며, gate 누설 전류의 감소와 방출 전류의 안정성을 확인하였다.

  • PDF