A Novel Switching Mode for High Power Factor Correction and Low THD

  • Park, Gyumin;Eum, Hyunchul;Yang, Seunguk;Hwang, Minha;Park, Inki
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.210-212
    • /
    • 2018
  • A new switching mode has been proposed to obtain high power factor and low THD in single stage AC-DC converter. The conventional voltage mode control in critical conduction mode distorts input current shape with poor THD in flyback topology. Once TRIAC dimmer is connected, visible flicker in the LED lamp is easily detected due to a lack of TRAIC holding current near the input voltage zero cross. The newly proposed method can shape the input current by providing a desired reference voltage so that low THD is obtained by ideal sinusoidal input current in case of no dimmer connection and flat input current performs good TRIAC dimmer compatibility in phase-cut dimming condition. To confirm the validity of the proposed method, theoretical analysis and experimental result from 8W dimmable LED lighting system are presented.

  • PDF

Improving the Dynamic Performance of Distribution Electronic Power Transformers Using Sliding Mode Control

  • Hooshmand, Rahmat-Allah;Ataei, Mohammad;Rezaei, Mohammad Hosein
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.145-156
    • /
    • 2012
  • These days, the application of electronic power transformers (EPTs) is expanding in place of ordinary power transformers. These transformers can transmit power via three or four wire converters. Their dynamic performance is extremely important, due to their complex structure. In this paper, a new method is proposed for improving the dynamic performance of distribution electronic power transformers (DEPT) by using sliding mode control (SMC). Hence, to express the dynamic characteristics of a system, different factors such as the voltage unbalance, voltage sag, voltage harmonics and voltage flicker in the system primary side are considered. The four controlling aims of the improvement in dynamic performance include: 1) maintaining the input currents so that they are in sinusoidal form and in phase with the input voltages so they have a unity power factor, 2) keeping the dc-link voltage within the reference amount, 3) keeping the output voltages at a fixed amount and 4) keeping the output voltages in sinusoidal and symmetrical forms. Simulation results indicate the potential and capability of the proposed method in improving DEPT behavior.

A Novel Hybrid Sequential Start Control System for Large Inductive Loads

  • Kim, Sang-Kon;Kim, Tae-Kon
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.388-394
    • /
    • 2015
  • The inrush current of a large inductive load can be reduced with a soft starter; however, the large inrush current caused by simultaneous bulk starts (SBSs) cannot be effectively reduced. In order to reduce the high inrush current and voltage sag owing to the SBSs of large capacity inductive loads within a power network, a novel hybrid sequential start control system is proposed, implemented on embedded systems, and evaluated with a testbed in this study. From the experimental and simulation results of the proposed control system, the inrush current could be effectively restricted below the maximum current capacity of a power distributing board. Moreover, with the proposed system, power cost typically dictated by the peak power consumption can be fairly reduced, and the quality of the power system connected to the inductive loads can be efficiently increased.

Detection of Anormalies on the Power Line using the Instantaneous Frequencies (순간주파수를 이용한 전력선 신호의 이상현상검출)

  • Iem, Byeong-Gwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.544-548
    • /
    • 2006
  • The instantaneous frequency gives a frequency value at a time instance. Thus, it is natural to use the instantaneous frequency for detecting disturbances of voltage signal in power line. Various instantaneous frequency estimators are introduced. By applying to different types of disturbed signals, we show the estimators' ability to classify flickers. Also, the computational costs are compared between different instantaneous frequency estimators. The Prony's method (PRONY) and the modified covariance method (MCOV) need relatively smaller amount of calculation than the Teaser-Kaiser energy operator based estimator (DESA II). For an AM-FM modulated signal, the tracking performance of different instantaneous frequency estimators is also compared. Through simulation, it is shown that MCOV produces less variant frequency estimation values than DESA II and PRONY method.

Analysis of 1/f Noise in Fully Depleted n-channel Double Gate SOI MOSFET

  • Kushwaha Alok;Pandey Manoj Kumar;Pandey Sujata;Gupta A.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.3
    • /
    • pp.187-194
    • /
    • 2005
  • An analysis of the 1/f or flicker noise in FD n-channel Double Gate SOI MOSFET is proposed. In this paper, the variation of power spectral density (PSD) of the equivalent noise voltage and noise current with respect to frequency, channel length and gate-to-source voltage at various temperatures and exponent $C(i.e\;1/f^c$ is reported. The temperature is varied 125 K from to room temperature. The variation of PSD with respect to channel length down to $0.1{\mu}m$ technology is considered. It is analyzed that l/f noise in FD n-channel Double Gate SOI MOSFET is due to both carrierdensity fluctuations and mobility-fluctuations. But controversy still exits to its origin.

A Control System for Attenuating Voltage-Dip and Inrush Current Caused by Starting of Inductive Load Nnetwork (유도성 부하 네트워크의 기동에 의한 순간전압강하 및 기동전류 감쇄를 위한 제어시스템)

  • Kim, Sang-Kon;Choi, In-Kyum;Kim, Tae-Kon;Seo, Sung-Kyu
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2012
  • We propose a control system consisted of TRIAC PWM module and sequential start control system attenuating voltage-dip and inrush current caused by starting of inductive load network. To minimize the high voltage-dip and inrush current induced from a large capacity inductive load, we developed a TRIAC PWM module. And we also developed a sequential start control system preventing simultaneous starting of the inductive loads within a same power network. According to the experimental results with the proposed control system, the voltage-dip and inrush current could be effectively attenuated such that they can meet the related international standards and resolve the issues associated with simultaneous starting of multiple inductive loads. By employing this system, power cost usually implemented by the estimation of peak power consumption can be reduced and the power quality of a power distribution system connected to the inductive load network can be stabilized efficiently.

Development of Image Quality Register Optimization System for Mobile TFT-LCD Driver IC (모바일 TFT-LCD 구동 집적회로를 위한 화질 레지스터 최적화시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.592-595
    • /
    • 2008
  • This paper presents development of automatic image quality register optimization system using mobile TFT-LCD (Thin Film Transistor-Liquid Crystal Display) driver IC and embedded software. It optimizes automatically gamma adjustment and voltage setting registers in mobile TFT-LCD driver IC to improve gamma correction error, adjusting time, flicker noise and contrast ratio. Developed algorithms and embedded software are generally applicable for most of the TFT-LCD modules. The proposed optimization system contains module-under-test (MUT, TFT-LCD module), control program, multimedia display tester for measuring luminance, flicker noise and contrast ratio, and control board for interface between PC and TFT-LCD module. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU.

  • PDF

A Study on Malfunction Mode of CMOS IC Under Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파로 인한 CMOS IC에서의 오동작 특성 연구)

  • Park, Jin-Wook;Huh, Chang-Su;Seo, Chang-Su;Lee, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.559-564
    • /
    • 2016
  • This study examined the malfunction mode of the HCMOS IC under narrow-band high-power electromagnetic wave. Magnetron is used to a narrow-band electromagnetic source. MFR (malfunction failure rate) was measured to investigate the HCMOS IC. In addition, we measured the resistance between specific pins of ICs, which are exposed and not exposed to the electromagnetic wave, respectively. As a test result of measurement, malfunction mode is shown in three steps. Flicker mode causing a flicker in LED connected to output pin of IC is dominant in more than 7.96 kV/m electric field. Self-reset mode causing a voltage drop to the input and output of IC during electromagnetic wave radiation is dominant in more than 9.1 kV/m electric field. Power-reset mode making a IC remained malfunction after electromagnetic radiation is dominant in more than 20.89 kV/m. As a measurement result of pin-to-pin resistance of IC, the differences between IC exposed to electromagnetic wave and normal IC were minor. However, the five in two hundred IC show a relatively low resistance. This is considered to be the result of the breakdown of pn junction when latch-up in CMOS occurred. Based on the results, the susceptibility of HCMOS IC can be applied to a basic database to IC protection and impact analysis of narrow-band high-power electromagnetic waves.

Single-Stage Quasi Resonant Type PSR(Primary Side Regulation) PWM Converter for the LED Drive in TRIAC Phase Controlled Dimmer (TRIAC위상 제어 조광기에서의 LED구동을 위한 Single-Stage 준 공진형 PSR(Primary Side Regulation) PWM 컨버터)

  • Han, Jae-Hyun;Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.84-94
    • /
    • 2013
  • In case when the existing TRIAC phase controlled dimmer is drove for the LED lighting equipments, there are many problems such as the LED flicker in low phase-angles, the acoustic noise and elements damage by increase of the peak voltage in the input filter capacitor, mulfunction by insufficiency of the TRIAC holding current, and the abnormal oscillation by LC resonant. In this paper, we proposes the single-stage quasi-resonant PSR(Primary Side Regulation) PWM converter, and the design, the simulation and experiment are performed. As a result, it could confirm that the proposed PWM converter is the lighting equipments for LED drive which can alternate the existing 60W class incandescent bulbs and it has the high drive performance of the efficiency 80% and over, the power factor 0.95 and over under the normal voltage 220V. Finally, total harmonic distortion(THD) is gratified with a standard[1] of the lighting equipments and the durability is evaluated as the high reliablilty of 150,000 hours and over.

Analysis of the Time-dependent Optical Properties of the Entire LCD Panel

  • Lee, Do-Young;Yoo, Ki-Taek;Park, Cheol-Woo;Lee, Kyung-Ho
    • Journal of Information Display
    • /
    • v.10 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • To understand panel driving more accurately, the optical properties and their distributions in the LCD panel itself, excluding the backlight, were investigated by measuring the transmittance of a one-dot pixel as a function of time. First, the behavior of time-dependent transmittance was analyzed, and it was found that the off-state TFT was not in a steady state but in a transient state during the holding period. Second, the time average, max, min, and range values of the transmittance curves were examined by varying the common voltage level and gray scale. Third, the analysis of such properties was expanded to cover those of the entire panel in all the gray scales. Lastly, the relationship between their properties and distributions was also investigated along with the contour plots.