• 제목/요약/키워드: voltage drop compensation

검색결과 81건 처리시간 0.029초

분산형전원이 연계된 배전계통의 전압조정에 관한 연구 (Voltage Regulation Method at the Power Distribution System interconnected with DSG System)

  • 최준호;추동욱;김재철;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.250-252
    • /
    • 1997
  • This paper deals with voltage regulation at the power Distribution system interconnected with DSG. Modern distribution substation adopt LDC method as the voltage regulation method to deliver suitable voltages to many customers. However, the operations of DSG interconnected with distribution system, the customers' voltage violate the permissible voltage limits. Therefore, to deliver suitable voltage to many customers at the distribution substation, an advanced voltage regulation method is required. In this paper, the on line realtime MLDC (Multiple Line Drop compensation) method, considered daedband and hysterical tap changing of the ULTC, is proposed. The result from a simulation study shows that the proposed method can be practical applications for the voltage regulation at the distribution system interconnected with DSG and unbalanced load pattern among feeders.

  • PDF

위상제어 정류기의 전류구간(Commutation) 보상 제어를 위한 새로운 계통 인덕턴스의 추정 방법 (A Novel Estimation Method of Grid Inductance for the Commutation Compensation Control of the Phase Controlled Rectifier)

  • 이종학;송승호
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.324-329
    • /
    • 2017
  • The phase controlled rectifier using thyristor is suitable for the high capacity and low-cost system. However, the rectifier output voltage drop is influenced by the grid inductance effect. Supposing the commutation area voltage and current are analyzed, the grid inductance can be estimated using the proposed algorithm. This paper presents the grid inductance estimation method for improved commutation compensation control of the phase controlled rectifier, and the proposed control algorithm effectiveness is verified by simulation.

비선형 모델링과 외란 관측기를 이용한 Matrix Converter로 구동되는 유도전동기 센서리스 벡터제어의 성능 개선 (Performance Improvement of Sensorless Vector Control for Induction Motor Drives Driven By Matrix Converter Using Non-Linearity Compensation and Disturbance Observer)

  • Kyo-Beum Lee
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.500-508
    • /
    • 2004
  • This paper presents a new sensorless vector control system for high performance induction motor drives fed by a matrix converter with non-linearity compensation and disturbance observer. The nonlinear voltage distortion that is caused by commutation delay and on-state voltage drop in switching device is corrected by a new matrix converter modeling. The lumped disturbances such as parameter variation and load disturbance of the system are estimated by the radial basis function network (RBFN). An adaptive observer is also employed to bring better responses at the low speed operation. Experimental results are shown to illustrate the performance of the proposed system.

PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구 (A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC)

  • 김병기;김기영;이주광;최성식;노대석
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1355-1363
    • /
    • 2015
  • 태양광전원이 연계된 배전계통에서 발생되는 과전압문제를 해소하기 위하여, 계통에서 발생하는 전압변동에 대응하여 전압을 일정하게 유지시킬 수 있는 선로 전압 조정장치(Step Voltage Regulator)의 도입이 제안되고 있다. 일반적으로 SVR은 전압조정 방법에 의하여 Tap위치를 결정한 후, 일정시간이 지나면 Tap이 동작하도록 운용된다. 하지만 지연시간(30sec) 이후에 Tap을 동작시키는 SVR의 특성에 의하여, 이 시간동안 수용가전압은 규정치를 벗어날 가능성을 가지고 있다. 따라서 본 논문에서는 배전계통의 상용소프트웨어인 PSCAD/EMTDC를 이용하여 LDC방법에 의한 SVR의 전압조정 모델링과, 양방향으로 유무효전력을 제어할 수 있는 전지전력저장장치(Battery Energy Storage System)의 모델링을 제안하였다. 또한 SVR의 문제점을 보완하기 위하여, BESS와의 협조방안에 대한 모델링을 제시하였다. 상기에서 제안한 모델링을 바탕으로 수용가의 전압특성을 분석한 결과, SVR과 BESS에 의하여 안정적으로 전압이 유지됨을 확인하여, 본 연구에서 제시한 모델링의 유효성을 입증하였다.

하이브리드 반도체 변압기의 1차측 정보를 이용한 2차측 간접 정전압 제어 기법 (Secondary Indirect Constant Voltage Control Technique for Hybrid Solid State Transformer using Primary Side Information)

  • 이태영;윤춘기;조영훈
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.420-423
    • /
    • 2020
  • This study proposes an indirect constant voltage control algorithm for hybrid solid-state transformers (HSSTs) by using primary side information. Considering the structure of HSSTs, measuring voltage and current information on the primary side of a transformer is necessary to control the converter and inverter of the power converter. The secondary side output voltage is measured to apply the conventional secondary side constant voltage control algorithm, and thus, the digital control board requires the same rated insulation voltage as that of the transformer. To solve this problem, the secondary voltage of the transformer obtained from the tap voltage is used. Moreover, output voltage decreases as load increases because the proposed indirect constant voltage control scheme does not consider the cable impedance between the secondary output terminal and the load. This study also proposes a technique for compensating the secondary output voltage by using the primary current of the transformer and the resistance value of the cable. An experiment is conducted using a scale-down HSST prototype consisting of a 660 V/220 V tap transformer. The problem of the proposed indirect constant voltage control strategy and the improvement effect due to the application of the compensation method are compared using the derived experimental results.

ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정 (The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems)

  • 김미영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

Advanced Repetitive Controller to Improve the Voltage Characteristics of Distributed Generation with Nonlinear Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.409-418
    • /
    • 2013
  • This paper presents an enhanced control strategy which consists of a proportional-integral controller and a repetitive controller (RC) for improving the voltage performance of distributed generation (DG) under nonlinear load conditions. The proposed voltage controller is able to maintain a sinusoidal voltage at the point of common coupling (PCC) of the DG regardless of the harmonic voltage drop in the system impedance due to nonlinear load currents. In addition, by employing the delay time of the RC at one-sixth of the fundamental period, the proposed RC can overcome the slow response drawback of the traditional PI-RC. The proposed control strategy is analyzed and the design of the RC is presented in detail. The feasibility of the proposed control strategy is verified through simulation and experimental results.

PQR 전력이론을 이용한 Matrix Converter 구동 시스템의 비선형특성 보상 (A Non-Linearity Compensation Method for Matrix Converter Drives Using PQR Power Theory)

  • 이교범
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.751-758
    • /
    • 2004
  • This paper presents a new method to compensate the non-linearity for matrix converter drives using PQR instantaneous Power theory. The non-linearity of matrix converter drives such as commutation delay, turn-on and turn-off time of switching device, and on-state switching device voltage drop is modelled by PQR power theory and compensated using a reference current control scheme. The proposed method does not need any additional hardware and off-line experimental measurements. The proposed compensation method is applied for high performance induction motor drives using a 3 kW matrix converter system without a speed sensor. Simulation and experimental results show the proposed method using PQR power theory Provides good compensating characteristic.

온도 보상 및 듀얼 루프를 이용한 부스트 컨버터 LED 드라이버 IC (A dual-loop boost-converter LED driver IC with temperature compensation)

  • 박지훈;윤성진;황인철
    • 한국산업정보학회논문지
    • /
    • 제20권6호
    • /
    • pp.29-36
    • /
    • 2015
  • 본 논문에서는 3개의 선형 전류 레귤레이터 그리고 자동 기준 전압 조절과 출력 전압 조절 루프를 포함하는 LED 배면광 드라이버 IC를 제안한다. 제안한 LED 드라이버에서 출력전압은 이중 피드백 루프를 통해 제어된다. 첫 번째 루프는 출력전압을 감지하고 조절하며, 두 번째 루프는 선형 전류 레귤레이터의 전압 강하를 감지하고 기준전압을 조정한다. 이러한 피드백 루프와, 선형 전류 레귤레이터의 전압강하는 드라이버 효율이 최대가 될 수 있는 최소값으로 유지된다. 드라이버의 출력은 각 채널당 4개의 LED를 가지는 3개의 채널 LED 구조이다. 휘도는 펄스 폭 변조(PWM) dimming 신호에 의해 조절된다. 제안한 드라이버는 0.35um의 60-V 고전압 공정에서 설계되었고, 측정 결과 최대 85% 정도의 효율을 가진다.

New Voltage Programming LTPS-TFT Pixel Scaling Down VTH Variation for AMOLED Display

  • Nam, Woo-Jin;Lee, Jae-Hoon;Choi, Sung-Hwan;Jeon, Jae-Hong;Han, Min-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.399-402
    • /
    • 2006
  • A new voltage-scaled compensation pixel which employs 3 p-type poly-Si TFTs and 2 capacitors without additional control line has been proposed and verified. The proposed pixel does not employ the $V_{TH}$ memorizing and cancellation, but scales down the inevitable $V_{TH}$ variation of poly-Si TFT. Also the troublesome narrow input range of $V_{DATA}$ is increased and the $V_{DD}$ supply voltage drop is suppressed. In our experimental results, the OLED current error is successfully compensated by easily controlling the proposed voltage scaling effects.

  • PDF