• Title/Summary/Keyword: voltage Transformer

Search Result 1,683, Processing Time 0.028 seconds

Design and FEM Analysis of Piezoelectric Ceramic Transformer for Low-Voltage Step-Down Application (강압용 압전변압기의 설계 및 유한요소해석)

  • Jueng, Hyon-Ho;Lee, Sang-Ki;Park, Tae-Gone;Lee, Won-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.70-73
    • /
    • 2000
  • This paper present a new sort of multilayer piezoelectric ceramic transformer for AC-adapter. This piezoelectric transformer operates in the second longitudinal vibration mode. The output voltage of the multilayer piezoelectric transformer was simulated using ANSYS, that is one of the FEM analysis program. As results, the minimum displacement was occurred at the two paints where one is the middle of input and the other is middle of output side in second thickness extensional vibration mode. And output voltage was inversely decreased by increasing number of output layers. 缀Ѐ㘰〻ሀ䝥湥牡氠瑥捨湯汯杹

  • PDF

Characteristics of a Continuous Disk Winding for High Voltage HTS Transformer (고전압 초전도 변압기용 연속 디스크 권선의 특성 해석)

  • Hwang, Young-In;Lee, Seung-Wook;Kim, Woo-Seok;Choi, Kyeong-Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.295-300
    • /
    • 2007
  • High temperature superconducting (HTS) windings for an HTS transformer which have been developed have two kinds of type, one is the layer winding and the other is disk winding. The layer winding has adopted for an HTS power transformer so far because of the small AC losses of the HTS windings. The disk windings have surface of the HTS wire. We propose a new winding method for a high voltage HTS transformer which has advantages of both type of HTS windings, and we call it continuous disk winding. This new HTS winding consists of pile of HTS disk windings. The continuous disk winding was fabricated with multi-stacked HTS wires for dover HTS transformer. We can check the potential possibility from the characteristic test of the fabricated winding. The new type HTS windings can be applied to HTS power transformers, especially to the high voltage ones.

Survey of Optical Current Sensor and Optical Voltage Sensor for Electric Power Systems (전력용 광 전류, 전압 센서 연구 동향 조사)

  • Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.270-273
    • /
    • 2001
  • In this paper, some of optical current transformers and optical potential transformers for extra high voltage system are introduced. The optical current transformer and optical potential transformer will be adopted in the near future, because of increasing demands of high accuracy and good reliability of current transformer and potential transformer. The application cases of optical current transformers and optical potential transformers are also introduced.

  • PDF

Transition of voltage-differential current under internal fault on power transformer (전력용 변압기 내부고장시 전압-차전류의 변화에 관한 연구)

  • Park, Jae-Sae
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.92-95
    • /
    • 2004
  • Power transformer is an important apparatus in transforming and delivering the power in a power system. It shows less accident ratio than other system apparatus, but once the accident occurs, it causes long-term operation stoppage and economic loss. It brings high bad spillover effects. Therefore, the role of protective relaying, which is to prevent internal fault a power transformer is highly important. This study proposed advanced algorithm that can clearly determine internal fault of the power transformer and magnetizing inrush, through numerical analysis by using the terminal voltage and input output current.

  • PDF

Design and FEM Analysis of Multilayer Piezoelectric Transformer for AC-adapter (AC-adapter를 위한 적층형 압전트랜스포머의 설계 및 유한요소해석)

  • 정현호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.529-533
    • /
    • 2000
  • This paper present a new sort of multilayer piezoelectric ceramic transformer for AC-adapt. This piezoelectric transformer operates n the second thickness extensional vibration mode. The output voltage of the multilayer piezoelectric transformer was simulated using ANSYS. As results, the maximum stress appeared at the two points where one is the middle of input and the other is middle of output side in Second thickness extensional vibration mode. And output voltage was inversely decreased by increasing number of output layers.

  • PDF

Coreless PCB transformer in HB ZVS DC/DC converter for vehicle FPL lamp power circuit (Coreless PCB 변압기를 이용한 자동차 전원 구동 FPL 램프 전원 회로)

  • Lee Wan-Yun;Chung Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.253-256
    • /
    • 2002
  • This paper proposes the application of coreless PCB transformer to Half-Bridge (HB), Zero-voltage-Switched (ZVS) DC/DC converter for FPL lamp with electronic ballast in vehicle. The designed 5 coreless PCB transformers for ballast driving voltage are parallel-connected in primary windings and series-connected in secondary windings. Coreless PCB transformer is designed to have spiral winding in order to transfer higher energy. The computer simulations of the proposed power circuit show coreless PCB transformer to have good performance.

  • PDF

A survey of the application cases of optical current and voltage sensors (광 전류.전압 센서의 적용사례 조사 연구)

  • Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.215-218
    • /
    • 2002
  • In this paper some of optical current transformers and optical potential transformers for extra high voltage system are introduced. The optical current transformer and optical potential transformer will be adopted in the near future, because of increasing demands of high accuracy and good reliability of current transformer and potential transformer. The application cases of optical current transformers and optical potential transformers are also introduced.

  • PDF

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

Compensation of the Secondary Voltage of a Coupling Capacitor Voltage Transformer (CCVT의 2차 전압 보상 방법)

  • Kang, Yong-Cheol;Zheng, Tai-Ying;Lee, Ji-Hoon;Jang, Sung-Il;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.909-914
    • /
    • 2008
  • A coupling capacitor voltage transformer(CCVT) is used in an extra or ultra high voltage system to obtain the standard low voltage signal for protection. To avoid the phase angle error between the primary and secondary voltages, a tuning reactor is connected between a capacitor and a voltage transformer. The inductance of the reactor is designed based on the power system frequency. If a fault occurs on the power system, the secondary voltage of the CCVT contains some errors due to a dc offset component and harmonic components resulting from the fault. The errors become severe in the case of a close-in fault. This paper proposes an algorithm for compensating the secondary voltage of a CCVT in the time-domain. From the measured secondary voltage of the CCVT, the secondary and primary currents are obtained; then the voltage across the capacitor and the inductor is calculated and then added to the measured secondary voltage to obtain the correct primary voltage. Test results indicate that the proposed algorithm can compensate the distorted secondary voltage of the CCVT irrespective of the fault distance, the fault inception angle, and the burden of the CCVT.

Compensation of the secondary voltage of a coupling capacitor voltage transformer in the time-domain (히스테리시스 특성을 고려한 CCVT 2차 전압 보상 방법)

  • Kang, Yong-Cheol;Zheng, Tai-Ying;Kim, Yeon-Hee;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.266-267
    • /
    • 2006
  • A coupling capacitor voltage transformer (CCVT) is used in extra high voltage and ultra high voltage transmission systems to obtain the standard low voltage signal for protection and measurement. To obtain the high accuracy at the power system frequency, a tuning reactor is connected between a capacitor and a voltage transformer (VT). Thus, no distortion of the secondary voltage is generated when no fault occurs. However, when a fault occurs, the secondary voltage of the CCVT has some errors due to the transient components resulting from the fault. This paper proposes an algorithm for compensating the secondary voltage of the CCVT in the time domain. With the values of the secondary voltage of the CCVT, the secondary and the primary currents are obtained; then the voltage across the capacitor and the tuning reactoris calculated and then added to the measured secondary voltage. The proposed algorithm includes the effect of the non-linear characteristic of the VT and the influence of the ferro-resonance suppression circuit. Test results indicate that the algorithm can successfully compensate the distorted secondary voltage of the CCVT irrespective of the fault distance, the fault inception angle and the fault impedance.

  • PDF