• 제목/요약/키워드: void volume fraction

검색결과 72건 처리시간 0.019초

통계적 방법을 이용한 복합조직강의 변형률과 보이드 성장거동에 관한 연구 (A Study on Strain-Void Growth Mechanism of Dual Phase Steel by Statistical Method)

  • 오경훈;유용석;오택열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.533-538
    • /
    • 2000
  • Ductile fracture of dual phase steel begins with void nucleation, at martensite-ferrite interface of deformed martensite particle. In this study, void nucleation, growth, and coalescence under various strain were studied in dual phase steel. Therefore, by means of the heat treatment of low carbon steel, the study deals with void nucleation and growth for ferrite grain size and martensite volume fraction of dual phase steel using statistical method. Void nucleation and growth with increasing strain are shown depend upon the ferrite grain size. Voids volume fraction generally increase as ferrite grain size decease.

  • PDF

Study on the unidirectional compaction of terminal cables in the CICC joint

  • 남현일;이호진;박재학;홍계원
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.218-223
    • /
    • 2002
  • The void volume fraction of cables is one of the effective parameters to characterize the joints of superconducting magnet. Because electrical resistance and cooling stability in the CICC (Cable-in-Conduit Conductors) joint are governed by the void volume fraction, it should be controlled constantly in the termination of cable. The change of cross-section shape in the cable was fecund during the unidirectional compaction of terminal sleeve. The non-uniform thickness of the sleeve after compaction is expected because the loading is not taxi-symmetric, and the plastic flow is also not axi-symmetric. The CICC was compacted from 45% void volume fraction to 15% by using two-piece compaction jig, which could be pressed mini-directionally. Commercial code, ABAQUS, was used to analyze the plastic flow in the sleeve during the unidirectional compaction. The increment of radius of curvature of compaction jig could minimize the change of the deformed shape of cables. The calculated results were agreed with the experimental observations.

  • PDF

섬유부피분율 증가와 공극 감소를 위한 VARTM 공정의 대기압 제어에 관한 연구 (A Study on the Atmospheric Pressure Control of the VARTM Process for Increasing the Fiber Volume Fraction and Reducing Void)

  • 곽성훈;김태준;탁윤학;권성일;이재현;김상용;이종천
    • Composites Research
    • /
    • 제34권2호
    • /
    • pp.88-95
    • /
    • 2021
  • VARTM(Vacuum-assisted resin transfer molding) 공정은 OoA(Out of Autoclave)에 속하는 저가형 공정기술로 다양한 분야에 널리 사용되어 왔다. 그러나 오토클레이브 공정보다 품질이 낮아 고신뢰성이 요구되는 항공산업에는 적용하기 어려웠다. VARTM 공정의 주요 문제는 오토클레이브 대비 낮은 섬유부피분율과 높은 Void 함량에 의한 기계적 물성의 손실이었다. 따라서 많은 연구자들이 Void를 줄이고 섬유부피분율을 높일 수 있는 연구를 수행해 왔다. 이러한 연구의 흐름에 따라 본 연구에서는 수지 주입 과정 중 대기압을 제어하는 방법이 섬유부피분율을 높이고 Void를 감소시킬 수 있는지 검토하였다. 신뢰성 평가는 Void와 연관성이 있는 압축강도시험, 섬유부피분율 분석, 광학현미경 촬영을 통해 확인하였다. 결과적으로 VARTM 공정에서 수지 주입과정 중 대기압을 단계별로 높이는 방법이 섬유부피분율 증가와 Void 감소에 직접적인 효과가 있음을 확인하였다.

원통형 셀 구조를 갖는 한방향 CFRP 적층 복합재료의 정적인장파괴거동 (Mechanical Properties and Fracture Behavior of Cylindrical Shell Type for Unidirectional CFRP Composite Material under Tension Load)

  • 오환섭
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.273-278
    • /
    • 1998
  • In this paper, basic micro-mechanical properties of unidirectional CFRP composite shell such as bonding strength, fiber volume fraction and void fraction are measured and tensile strength test is performed with a fixture. And then fracture surfaces are observed by SEM. In case of basic micro-mechanical properties, bonding strength is reduce with decreasing of radius of each ply in a shell for the effect of residual stress, fiber volume fraction is smaller than plate, and void fraction is vise versa. For these reason, tensile strength of shell is smaller than plate fabricated with same prepreg. For failure mode shell has many splitted part along its length, and it is assumed that this phenomenon is caused by the difference of bonding strength for residual stress.

  • PDF

자연마섬유보강 비소성 무기결합재 다공성 콘크리트의 공극률, 압축강도 및 동결융해저항성 평가 (Void Ratio, Compressive Strength and Freezing and Thawing Resistance of Natural Jute Fiber Reinforced Non-Sintering Inorganic Binder Porous Concrete)

  • 김황희;김춘수;전지홍;박찬기
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.67-73
    • /
    • 2015
  • This study evaluated the effects of fibers on the void ratio, compressive strength and repeated freezing and thawing resistance of porous vegetation concrete with binder type (non-sintering inorganic binder and blast furnace slag cement) and natural jute fiber volume fraction (0.0 %, 0.1 % and 0.2 %). The natural jute fiber volume fraction affected the void ratio, compressive strength and repeated freezing and thawing resistance. Added of natural jute fiber resulted in improved properties of the void ratio, compressive strength and freezing and thawing resistance. Also, the both compressive strength and freezing and thawing resistance increased with natural jute fiber volume fraction up to 0.1 % and then decreased with fiber volume fraction at 0.2 %.

일축 압축하중 하 다공성 폴리우레탄폼의 재료비선형 거동 및 미세구조 변화 (Material Nonlinear Behavior and Microstructural Transition of Porous Polyurethane Foam under Uniaxial Compressive Loads)

  • 이은선;고태식;이치승
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.688-694
    • /
    • 2017
  • Porous materials such as polymeric foam are widely adopted in engineering and biomedical fields. Porous materials often exhibit complex nonlinear behaviors and are sensitive to material and environmental factors including cell size and shape, amount of porosity, and temperature, which are influenced by the type of base materials, reinforcements, method of fabrication, etc. Hence, the material characteristics of porous materials such as compressive stress-strain behavior and void volume fraction according to aforementioned factors should be precisely identified. In this study, unconfined uniaxial compressive test for two types of closed-cell structure polyurethane foam, namely, 0.16 and $0.32g/cm^3$ of densities were carried out. In addition, the void volume fraction of three different domains, namely, center, surface and buckling regions under various compressive strains (10 %, 30 %, 50 % and 70 %) were quantitatively observed using Micro 3D Computed Tomography(micro-CT) scanning system. Based on the experimental results, the relationship between compressive strain and void volume fraction with respect to cell size, density and boundary condition were investigated.

Precise Void Fraction Measurement in Two-phase Flows Independent of the Flow Regime Using Gamma-ray Attenuation

  • Nazemi, E.;Feghhi, S.A.H.;Roshani, G.H.;Gholipour Peyvandi, R.;Setayeshi, S.
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.64-71
    • /
    • 2016
  • Void fraction is an important parameter in the oil industry. This quantity is necessary for volume rate measurement in multiphase flows. In this study, the void fraction percentage was estimated precisely, independent of the flow regime in gas-liquid two-phase flows by using ${\gamma}-ray$ attenuation and a multilayer perceptron neural network. In all previous studies that implemented a multibeam ${\gamma}-ray$ attenuation technique to determine void fraction independent of the flow regime in two-phase flows, three or more detectors were used while in this study just two NaI detectors were used. Using fewer detectors is of advantage in industrial nuclear gauges because of reduced expense and improved simplicity. In this work, an artificial neural network is also implemented to predict the void fraction percentage independent of the flow regime. To do this, a multilayer perceptron neural network is used for developing the artificial neural network model in MATLAB. The required data for training and testing the network in three different regimes (annular, stratified, and bubbly) were obtained using an experimental setup. Using the technique developed in this work, void fraction percentages were predicted with mean relative error of <1.4%.

기포탑 유동에서의 기포분율과 혼합정도의 상관관계 (Relationship between void fraction and mixing in bubble column flow)

  • ;이주범;박형민
    • 한국가시화정보학회지
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2017
  • Control of mixing and transport processes are the key areas that can be benefited by understanding the hydrodynamics in gas-liquid two-phase flows. In particular, the enhanced bubble-induced liquid-phase mixing is known to be a function of void fraction distribution, gas phase velocity and so on. To further our insight on the characteristics of the liquid-phase mixing induced by the bubbles, in the present study, we experimentally investigate the mixing performance of a rectangular bubble column while changing the void fraction from 0.006 to 0.075%. A shadowgraphy technique is used to measure the gas-phase properties such as void fraction and size/velocity of bubbles. On the other hand, we use dye visualization with low diffusive buoyant dye to directly measure the level of mixing. Finally, we confirm that the time taken for full mixing scales with the inverse of volume void fraction.

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

  • KO, MIN SEOK;LEE, BO AN;WON, WOO YOUN;LEE, YEON GUN;JERNG, DONG WOOK;KIM, SIN
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.804-813
    • /
    • 2015
  • The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor.

황토를 포함한 다공성 식생콘크리트의 역학적 특성 및 내약품성에 미치는 보강섬유의 효과 (Effect of Reinforcing Fiber on Mechanical Properties and Chemical Resistance of Porous Concrete with Hwang-toh)

  • 이진형;박찬기;박종식
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.105-113
    • /
    • 2011
  • 본 연구는 보강섬유의 종류(마섬유, 펄프섬유, PVA섬유, 나이론섬유) 및 혼입률(0.0%, 0.1%, 0.2%, 0.3%)이 다공성 식생콘크리트의 역학적 특성과 내약품성에 미치는 효과를 평가하였다. 시험은 섬유의 종류 및 혼입률의 변화에 따른 다공성 식생콘크리트의 압축강도, 공극률, pH, 휨강도 및 내약품성 특성을 분석하기 위하여 수행하였다. 섬유의 종류 및 혼입률은 다공성 식생콘크리트의 압축강도, 공극률 및 내약품성에 영향을 미쳤다. 섬유의 혼입률이 증가할수록 압축강도, 휨강도 및 공극률은 증가하였다. 그렇지만 다공성 식생콘크리트의 pH 값과 내약품성은 섬유의 종류 및 혼입률의 변화에 큰 영향이 없었다.