• Title/Summary/Keyword: void detection

Search Result 69, Processing Time 0.026 seconds

A Development of Automatic Defect Detection Program for Small Solid Rocket Motor (소형 로켓 모타의 결함 자동 판독 프로그램 개발)

  • Lim, Soo-Yong;Son, Young-Il;Kim, Dong-Ryun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • This paper presents the development of automatic defect detection program using 3D computed tomography image of small solid rocker motor. We applied the neighbor pixel comparison algorithm with beam hardening correction for the recognition of defect. We made the artificial defect specimen in order to decide a standard CT value of defect. The program was tested with 150 small solid rocket motors and it could detect the disbond, crack, foreign material and void. The program showed more reliable and faster results than human inspector's interpretation.

A Study on the Selection of GPR Type Suitable for Road Cavity Detection (도로동공 탐지에 적합한 GPR 타입 선정에 관한 연구)

  • Kim, Yeon Tae;Choi, Ji Young;Kim, Ki Deok;Park, Hee Mun
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.69-75
    • /
    • 2017
  • PURPOSES : The purpose of this study is to evaluate different types of Ground Penetrating Radar (GPR) testing for characterizing the road cavity detection. The impulse and step-frequency-type GPR tests were conducted on a full-scale testbed with an artificial void installation. After analyzing the response signals of GPR tests for detecting the road cavity, the characteristics of each GPR response was evaluated for a suitable selection of GPR tests. METHODS : Two different types of GPR tests were performed to estimate the limitation and accuracy for detecting the cavities underneath the asphalt pavement. The GPR signal responses were obtained from the testbed with different cavity sizes and depths. The detection limitation was identified by a signal penetration depth at a given cavity for impulse and step-frequency-type GPR testing. The unique signal characteristics was also observed at cavity sections. RESULTS : The impulse-type GPR detected the 500-mm length of cavity at a depth of 1.0 m, and the step-frequency-type GPR detected the cavity up to 1.5 m. This indicates that the detection capacity of the step-frequency type is better than the impulse type. The step-frequency GPR testing also can reflect the howling phenomena that can more accurately determine the cavity. CONCLUSIONS :It is found from this study that the step-frequency GPR testing is more suitable for the road cavity detection of asphalt pavement. The use of step-frequency GPR testing shows a distinct image at the cavity occurrences.

A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS (GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구)

  • Koo Ja-Yoon;Chang Yong-Moo;Choi Jae-Ok;Yeon Man-seung;Lee Ji-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge (부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • 김성홍;박재준;김재환
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

A Study on the Evaluation of Weldability in Spot Welding (저항용접에서의 용접성 평가에 관한 연구)

  • 홍민성;김종민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.301-306
    • /
    • 2003
  • Spot welding is frequently used for industrial purpose, such as automobile and aerospace industries and household appliances due to its high performance. In these day, robotization and systemization of welding process made it possible to produce more precise or smaller electric parts. And when it comes to welding of steel sheet, the size of nugget must be getting smaller. Therefore, welding conditions are limited to avoid defects, such as deformation, damage, weakening of joining area. In this research, the measurement of the nugget size by the nondestructive inspection has been conducted. As a result, the right estimation of the nugget size and void defects, the detection of corona bond near joining area, the selection of the optimum ultrasonic mode, and set up for ultrasonic inspection are studied. From the trustworthy solutions of nugget size estimated by results of measurement, the optimum inspection conditions depending upon the width of welding parts are determined as well.

  • PDF

A methodology for spatial distribution of grain and voids in self compacting concrete using digital image processing methods

  • Onal, Okan;Ozden, Gurkan;Felekoglu, Burak
    • Computers and Concrete
    • /
    • v.5 no.1
    • /
    • pp.61-74
    • /
    • 2008
  • Digital image processing algorithms for the analysis and characterization of grains and voids in cemented materials were developed using toolbox functions of a mathematical software package. Utilization of grayscale, color and watershed segmentation algorithms and their performances were demonstrated on artificially prepared self-compacting concrete (SCC) samples. It has been found that color segmentation was more advantageous over the gray scale segmentation for the detection of voids whereas the latter method provided satisfying results for the aggregate grains due to the sharp contrast between their colors and the cohesive matrix. The watershed segmentation method, on the other hand, appeared to be very efficient while separating touching objects in digital images.

DETECTION OF X-RAY EMISSION FROM GALAXIES INSIDE AND TOWARDS THE NEARBY VOIDS

  • KIM CHULHEE;BOLLER TH.;GHOSH KAJAL K.
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • We searched for X-ray emission from the 665 galaxies inside and towards the nearby voids by analyzing the ROSAT All-Sky Survey (RASS) data as well as the ROSAT pointed observations (PSPC). As a result we have detected six X-ray emitting galaxies. Two (UGC 10205 and NGC 7509) are in the high density region in the local void, three (UGC 749, MCG +11-10-073, and Mrk 464) are towards the nearby voids, and UGC 32 is located in the low density region. We carried out a timing analysis for both Mrk 464 and UGC 32, and a spectral analysis for Mrk 464. The light curve of Mrk 464 shows the possibility of periodic X-ray flux variation and UGC 32 shows weak, but rapid variation.

The Diagonosis of Treeing Breakdown Simultaneous Detection on Charge of Partial Discharge and Acoustic Emission Pulse (방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • Choi, J.K.;Kim, S.H.;Park, J.J.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1781-1783
    • /
    • 1996
  • Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with a artificial needle shape void by the charge of partial discharge and acoustic emission pulse in each phase angle area at the same time. We have analyzed the ${\Phi}-Q-n$ pattern and the insulation diagnosis of the samples using statistic operators such as charge magnitude and A.E pulse factor, skweness, kurtosis, G,C. Therefore, the relation between the charge of partial discharge and A.E pulse will be helpful and efficient to predict the breakdown just before the breakdown occure.

  • PDF

A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge (부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구)

  • Kim, Ji-Hong;Koo, Ja-Yoon;Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.

The measurement of partial discharge for preventive diagnosis in power machinery (전력용 기기의 예방진단을 위한 부분방전측정)

  • 김태성;구할본;임장섭;정우성
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF