• Title/Summary/Keyword: visual measurement

Search Result 930, Processing Time 0.024 seconds

Effective Customer Risk Management at the Nuclear Medicine Department: Risk Managemont MOT Development Application and Producing Public Relations Film (핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작)

  • Ham, Jong-Hum;Hwang, Jae-Bong;Kim, Joon-Ho;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.110-122
    • /
    • 2009
  • Purpose: Nowadays, A medical institution assesment could get more interest about a quality of medical services from many hospitals that developed the active activities for improving medical services. Also, there is an other additional issue which is the patients risk management. Uijeongbu ST. Mary's hospital Nuclear Medicine department has been changed many work process after PET-CT introduction and renovation of its place since 2008. Therefore, modified structure and the way of existing work process have contained risk factors. The purpose of this study would be the appropriate risk management process while imaging examination process, the removal risk factors and improved activities through the analysis risk factors. Materials and Methods: Nuclear Medicine department new process should analysis through many-sided, Firstly, make and trained risk management manual after then apply an actual work. Result analysis showed the number of risk accident occurrence that comparing the last year and after the improved activities. Secondly, producing risk management public relations film has been showed an applicable patient after then the customer service measurement checked for a hundred patient by questionnaire. Lastly, Risk factors were eliminated through the facilities participation improving activities which could change for the better risk factors. Results: The number of safety accident occurrence(medication error, fall and collision) were checked as zero after the improving activities both PET-CT and gamma camera examination. The results of questionnaire showed as follows; 74% marked as understanding of the test process and 81% checked "satisfaction" after the public relations film showing. The question "Did you consider about the risk factors?", both PET-CT and gamma camera checked as 94% and 89% respectively. Customer risk management could be accomplished effectively through the improving activities at the nuclear medicine department. Conclusions: The study would be an opportunity that spread risk factors were systematically showed and analyzied. Also, It showed the possibility of the minimized safety accident and its feedback, if application of the response manuel that could be a standard of radiology technician's work method to react safety accident. It was the more effective that visual material could be easy to approach as a methodology of risk factors. As far as I have concerned that It could help the safety and convenience through continuous and detailed activities that offer to patients.

  • PDF

A Study on Automated Lineament Extraction with Respect to Spatial Resolution of Digital Elevation Model (수치표고모형 공간해상도에 따른 선구조 자동 추출 연구)

  • Park, Seo-Woo;Kim, Geon-Il;Shin, Jin-Ho;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.439-450
    • /
    • 2018
  • The lineament is a linear or curved terrain element to discriminate adjacent geological structures in each other. It has been widely used for analysis of geology, mineral exploration, natural disasters, and earthquake, etc. In the past, the lineament has been extracted using cartographic map or field survey. However, it is possible to extract more efficiently the lineament for a very wide area thanks to development of remote sensing technique. Remotely sensed observation by aircraft, satellite, or digital elevation model (DEM) has been used for visual recognition for manual lineament extraction. Automatic approaches using computer science have been proposed to extract lineament more objectively. In this study, we evaluate the characteristics of lineament which is automatically extracted with respect to difference of spatial resolution of DEM. We utilized two types of DEM: one is Shuttle Radar Topography Mission (SRTM) with spatial resolution of about 90 m (3 arc sec), and the other is the latest world DEM of TerraSAR-X add-on for Global DEM with 12 m spatial resolution. In addition, a global DEM was resampled to produce a DEM with a spatial resolution of 30 m (1 arc sec). The shaded relief map was constructed considering various sun elevation and solar azimuth angle. In order to extract lineament automatically, we used the LINE module in PCI Geomatica software. We found that predominant direction of the extracted lineament is about $N15-25^{\circ}E$ (NNE), regardless of spatial resolution of DEM. However, more fine and detailed lineament were extracted using higher spatial resolution of DEM. The result shows that the lineament density is proportional to the spatial resolution of DEM. Thus, the DEM with appropriate spatial resolution should be selected according to the purpose of the study.

Effect of joint mobilization on improvement of knee pain, isokinetic strength, muscle tone, muscle stiffness in an elite volleyball player with knee injury (무릎손상 엘리트 배구선수에 관절가동운동이 무릎통증, 등속성 근력, 근긴장도, 근경직 개선에 미치는 효과)

  • Wang, Joong-San;An, Ho-Jung;Kim, Yong-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.326-333
    • /
    • 2016
  • This case study identified the effects of joint mobilization on knee pain, isokinetic strength, muscle tone, and muscle stiffness in an elite volleyball player with a knee injury. The subject had experienced cartilage defects of the left knee joint and underwent surgery to correct the condition. The patient complained of continuous pain in the left knee joint in daily life in addition to pain during exercise. The study was conducted from August 5 to 12, 2015 and joint mobilization was applied to the left knee joint for 15 minutes once a day for 8 days. Knee pain was measured using a visual analogue scale, and the concentric peak torque of the quadriceps and hamstring muscles was measured using an isokinetic muscular strength measurement device. The muscle tone and stiffness of the rectus femoris muscle, vastus medialis, and vastus lateralis on the injured side were measured using a myotonometer. All the measurements were conducted before and after the intervention. Joint mobilization was effective in reducing knee pain on the injured side, increasing the concentric peak torque of the quadriceps and hamstring muscles on both sides, and increasing the muscle stiffness of the quadriceps muscle on the injured side. Concentric peak torque of the quadriceps muscle on the injured side increased a great deal as the number of joint mobilizations was increased, largely diminishing the difference in concentric peak torque between the normal side and injured side. On the other hand, joint mobilization was ineffective in improving the hamstring to quadriceps strength ratio on the injured side. While this study suggests that joint mobilization can be an effective intervention to improve the knee pain, isokinetic strength, and muscle stiffness of elite volleyball players, it should be performed alongside training for an appropriate strength ratio.

THE ANTICANCER EFFECT OF PACLITAXEL($Taxol^{(R)}$) IN ORAL SQUAMOUS CELL CARCINOMA XENOGRAFT (이종 이식된 구강편평세포 암종에서 Paclitaxel ($Taxol^{(R)}$)의 항암 효과)

  • Kim, Ki-Hwan;Kim, Chul-Hwan;Han, Se-Jin;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.95-110
    • /
    • 2006
  • The treatment for oral and maxillofacial carcinoma with chemotherapeutic agents is evaluated by many effective methods to reduce the tumor mass and cancer cell proliferation. However these chemotherapy have many serious side effects, such as bone marrow suppression, renal toxicity, G-I troubles. Therefore a possible approach to develop a clinically applicable chemotherapeutic agent is to screen anticancer activity of Taxol which is known to have very little side effect and have been used to breast cancer and ovarian carcinoma. Taxol is a new anti-microtubular anti-cancer agent extracted from the bark of the Pacific yew, Taxus brevifolia. Paclitaxel(Taxol) acts by promoting tubulin polymerization and over stabilizing microtubules agianst depolymerization. Despite the constant improvements of methods of the cancer treatment especially chemotherapy, the rate of cancer metastasis and recurrent are not decreased. Thus the investigation of new drug which have very little side effect and a possible clinically application continues to be a high priority. Considering that the Taxol have shown very effective chemotherapeutic agent with relatively low toxicity in many solid tumors, it deserves to evaluate its efficacy in oral squamous cell carcinoma. In this study, to investigate the in-vivo and in-vitro anti-cancer efficacy of Taxol in oral squamous cell carcinoma and lastly, the potency of Paclitaxel in the clinical application for oral cancer was evaluated. In vivo study, after HN22 cell line were xenografted in nude mice, the growth of tumor mass was observed, 3 mg/Kg taxol was injected intraperitoneally into nude mice containing tumor mass. The methods of these study were measurement of total volume of tumor mass, histopathologic study, immunohistochemical study, drug resistance assay, growth curve, MTT assay, flow cytometry, cDNA microarray in vivo and in vitro. The results were obtained as following. 1. The visual inspection of the experimental group showed that the volume of the tumor mass was slightly decreased but no significant difference with control group. 2. Ki-67 index was decreased at weeks 4 in experimental group. 3. Microscopic view of the xenografted tumor mass showed well differentiated squamous cell carcinoma and after Taxol injection, some necrotic tissue was seen weeks 4. 4. The growth curve of the tumor cells were decreased after 1day Taxol treatment. 5. According to the MTT assay, HN22 cell line showed relative drug resistancy above $5\;{\mu}g/ml$ concentrations of Taxol. 6. In drug resistance assay, the decrease of cell counts was seen relatively according to concentration. 7. In Flow cytometry, G2M phase cell arrests were seen in low concentration of the Taxol, while S phase cell arrests were seen in high concentration of the Taxol. 8. Using cDNA microarray technique, variable gene expression of ANGPTL4, TXNRD1, FAS, RRAGA, CTGF, CYCLINEA, P19, DUSP5, CEBPG, BTG1 were detacted in the oral squamous cell carcinoma cell after taxol treatment. In this study paclitaxel is effective against oral squamous cell carcinoma cell lines in vitro, but week effect was observed in vivo. So we need continuous study about anticancer effect of taxol in vivo in oral squamous cell carcinoma.

Improvement of Melanin Production and Skin Tone by Fullerene Serum (플러린 함유 세럼의 멜라닌색소 및 피부톤 개선 효과)

  • Lim, Hyun-Sook;Lee, Mi-Bun;Lee, Jae-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.455-464
    • /
    • 2018
  • This study investigated whether the whitening effects of fullerene serum occurred through improvement of melanin production and skin tone and evaluated its potential for use as a cosmetic material for adult women aged 30-55 with dull skin color and pigmentation. Subjects were divided into a control group with fullerene-less serum (B) and an experimental group with serum containing 0.1% fullerene (A) and evaluated over 8 weeks. Visual assessment and measurement of skin conditions (melanin index, skin brightness) were conducted before use of and 4 and 8 weeks after use of the product, and a questionnaire survey and safety assessment were conducted at the end of the experiment. The results revealed that the highest decrease was 0.37% in the experimental group (A) after eight weeks of use of the product, but that this difference was not statistically significant. Moreover, no significant differences were observed upon inter-group comparison. Evaluation of changes in the melanin index and inter-group comparison revealed a significant decline in the experimental group (A) at all time points. Additionally, the $L^*$ value (skin brightness) of the experimental group (A) showed a significant increase (improvement) after eight weeks, while in inter-group comparison revealed a significant increase (improvement) at all time points (4 and 8 weeks later) (p<0.05). Based on a questionnaire survey of efficacy, positive response rates such as improvement of the target parts on week 8 were high in terms of 'improvement of skin color.' Moreover, the safety assessment revealed no adverse reactions. In conclusion, serum containing 0.1% fullerene revealed improved melanin production and skin tone (brightness) and confirmed its potential for use as a cosmetic material with brightening efficacy. Taken together, the results of this study indicate systematic investigation of the effective application and cosmetics formulations of this product are warranted.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Influences of a Sound Design of Media Contents on Communication Effects - TV-CF Sound Using a BQ-TEST (영상음향의 사운드디자인설계가 커뮤니케이션 효과에 미치는 영향 - TV광고음향을 뇌 지수 분석기법으로 -)

  • Yoo, Whoi-Jong;Suh, Hyun-Ju;Moon, Nam-Mee
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.602-611
    • /
    • 2008
  • The sound design performed in the production of media contents, such as TV, movie, and CF, have been conducted through the experienced feeling of some experts in the aspect of auditory effects that communicates stories. Also, there have been few studies of the quantitative approach and verification to apply visual and auditory effects felt by users. This study is a non-equivalent control group pretest-posttest design and investigates the difference in communication effects in which the difference in a sound design in the production of media contents that affects users. This study analyzed the brain quotient (BQ) obtained by the measurement of brain waves during the watching of an experiment image (track A) designed by using a 60-second TV CF only and an experiment image (track B) designed by sound effects and music and investigated which sound design represents differences in communication effects for users. The results of this investigation can be summarized as follows: First, in the results of the comparison of the attention quotient (ATQ), which is the BQ of recognition effects, between A and B tracks, the track A showed a higher difference in activation than the track B. It can be analyzed that the sound design based on music showed higher levels in attention and concentration than that of the sound effect design. Second, in the results of the comparison of the emotional quotient (EQ), which is emotional effects, between A and B tracks, the track A represented a higher difference than the track B. It means that the sound design based on music showed higher contribution levels in emotional effects than that of the design based on sound effects. Third, in the results of the comparison of the left and right brain equivalent quotient (ACQ), which is memory activation effects, between A and B tracks, there were no significant differences. In the results of the experiments, although there are some constraints in TV CF based on the conventional theories in which sound effects based design affects strong concentration, and music based design affects emotional feeling, the music based design may present more effects in continued concentration. In addition, it was evident that the music based design showed higher effects in emotional aspects. However, it is necessary to continue the study by increasing the number of subjects for improving the little differences in ACQ. This study is useful to investigate the communication effects of the sound based design in media contents as a quantitative manner through measuring brain waves and expect the results of this study as the basic materials in the fields of sound production.

Developing an Instrument for Analysing Students' Behavioral Engagement in School Science Classroom (과학수업에서 나타나는 학생들의 행동적 참여 분석을 위한 영상 분석 도구의 개발)

  • Choi, Joonyoung;Na, Jiyeon;Song, Jinwoong
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.2
    • /
    • pp.247-258
    • /
    • 2015
  • Students are engaged in classroom learning, and classroom learning occurs not only through conversation but also through nonverbal behavior. In science classrooms especially, there are meaningful nonverbal behaviors such as practical activities like observation and measurement. But these behaviors have not been properly investigated by existing instruments that try to measure students' engagement. This study aims to develop a new instrument for analyzing students' behavioral engagement especially in science classrooms. The method of developing the instrument was structured along three steps. First, student behaviors have been classified into fourteen categories through literature review and a series of observation of elementary science classroom. Second, based on these, a framework for analyzing student behavioral engagement has been developed. With the framework, every student moment could be labeled as Participatory Speech or Participatory Silence or Non-Participatory Speech or Non-Participatory Silence. Third, an instrument to which the framework is applied has been developed by using Microsoft Excel. As a trial, two fourth-grade students in elementary science class were analyzed with this instrument. The results of the trial analysis shows that the longest period of a science lesson was occupied by Participatory Silence (63% and 72%). Among the participatory silence, 'listening' was the most common (51% and 42% of the trial lesson) and 'observing' which is a specific behavior to science was the fourth position (17% and 17% of the trial lesson). It is expected that the developed instrument could be used in improving our understanding of the patterns of student engagement in science classrooms.