• 제목/요약/키워드: view reconstruction

검색결과 315건 처리시간 0.028초

서울시 수유1동 국민주택단지의 변화특성에 관한 연구 (A Study on the Change Characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul)

  • 이성운;김경연;전병권
    • 대한건축학회논문집:계획계
    • /
    • 제34권5호
    • /
    • pp.21-28
    • /
    • 2018
  • This study analyzed the physical characteristics and change characteristics of urban detached residential area. In the reality of South Korea in which the history of modern urbanization is not long, the densification that progressed together with sudden population growth without any consideration of city plans became to reveal many problems. Thereafter, apartment-centered large scaled development plans have been implemented until now as an alternative for the foregoing. As the residential environments of old downtown areas that were excluded from the development have been gradually deteriorated, large scaled re-development and reconstruction projects have been adopted as ways to solve the problems of the old downtown areas. On one hand, the development methods that damage the history of the detached housing areas have been resisted. With such a background, this study attempted the analysis of the change characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul with a view to playing the role of evidentiary materials for the disappearing urban detached housing areas or those urban detached housing areas that may be revived. This author hopes and the results of this study will lead to careful development that presents measures to maintain and develop modern urban residential areas where the history of past residential areas and culture are disappearing due to full-scale redevelopment.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

딥러닝을 활용한 3차원 초음파 파노라마 영상 복원 (3D Ultrasound Panoramic Image Reconstruction using Deep Learning)

  • 이시열;김선호;이동언;박춘수;김민우
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권4호
    • /
    • pp.255-263
    • /
    • 2023
  • Clinical ultrasound (US) is a widely used imaging modality with various clinical applications. However, capturing a large field of view often requires specialized transducers which have limitations for specific clinical scenarios. Panoramic imaging offers an alternative approach by sequentially aligning image sections acquired from freehand sweeps using a standard transducer. To reconstruct a 3D volume from these 2D sections, an external device can be employed to track the transducer's motion accurately. However, the presence of optical or electrical interferences in a clinical setting often leads to incorrect measurements from such sensors. In this paper, we propose a deep learning (DL) framework that enables the prediction of scan trajectories using only US data, eliminating the need for an external tracking device. Our approach incorporates diverse data types, including correlation volume, optical flow, B-mode images, and rawer data (IQ data). We develop a DL network capable of effectively handling these data types and introduce an attention technique to emphasize crucial local areas for precise trajectory prediction. Through extensive experimentation, we demonstrate the superiority of our proposed method over other DL-based approaches in terms of long trajectory prediction performance. Our findings highlight the potential of employing DL techniques for trajectory estimation in clinical ultrasound, offering a promising alternative for panoramic imaging.

Anatomic coracoclavicular ligament reconstruction with triple flip-buttons leads to good functional outcomes and low reduction loss: a case series

  • Raul Aguila;Gonzalo Gana;J Tomas Munoz;Diego Garcia de la Pastora;Andres Oyarzun;Gabriel Mansilla;Sebastian Coda;J Tomas Rojas
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.140-147
    • /
    • 2023
  • Background: The management of acromioclavicular (AC) joint dislocation remains controversial. Recently, anatomic coracoclavicular (CC) fixation with a double clavicular tunnel and three flip-buttons has shown promising results. This study aimed to evaluate functional and radiological outcomes in patients with high-grade AC joint dislocation treated with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Methods: A retrospective, unicentric study was performed. The study included patients with high-grade AC joint dislocation who underwent surgery with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Demographic data were obtained from medical records. A functional evaluation using subjective shoulder value (SSV), visual analog scale (VAS), and disabilities of the arm, shoulder, and hand (DASH) questionnaires was performed, and an evaluation of preoperative and postoperative comparative Zanca view images was performed. Factors associated with functional outcomes and radiological AC reduction were analyzed. Results: A total of 83 patients completed follow-up and were included in the analysis. The mean SSV, VAS, and DASH scores were 92.8, 0.8, and 6.4, respectively. Patients who had complications experienced significantly worse functional outcomes (DASH: P=0.037). Suboptimal final AC reduction was observed in nine patients (11.1%), and significantly more frequently in patients older than 40 years (P=0.031) and in surgeries performed more than 7 days after injury (P=0.034). There were two reoperations (2.4%). Conclusions: Anatomic CC fixation with a double clavicular tunnel and three flip-buttons leads to good functional outcomes, low complication rates, and high rates of optimal AC reduction.

A Novel Draft Genome-Scale Reconstruction Model of Isochrysis sp: Exploring Metabolic Pathways for Sustainable Aquaculture Innovations

  • Abhishek Sengupta;Tushar Gupta;Aman Chakraborty;Sudeepti Kulshrestha;Ritu Redhu;Raya Bhattacharjya;Archana Tiwari;Priyanka Narad
    • 한국미생물·생명공학회지
    • /
    • 제52권2호
    • /
    • pp.141-151
    • /
    • 2024
  • Isochrysis sp. is a sea microalga that has become a species of interest because of the extreme lipid content and rapid growth rate of this organism indicating its potential for efficient biofuel production. Using genome sequencing/genome-scale modeling for the prediction of Isochrysis sp. metabolic utilities there is high scope for the identification of essential pathways for the extraction of byproducts of interest at a higher rate. In our work, we design and present iIsochr964, a genome-scale metabolic model of Isochrysis sp. including 4315 reactions, 934 genes, and 1879 metabolites, which are distributed among fourteen compartments. For model validation, experimental culture, and isolation of Isochrysis sp. were performed and biomass values were used for validation of the genome-scale model. OptFlux was instrumental in uncovering several novel metabolites that influence the organism's metabolism by increasing the flux of interacting metabolites, such as Malonyl-CoA, EPA, Protein and others. iIsochr964 provides a compelling resource of metabolic understanding to revolutionize its industrial applications, thereby fostering sustainable development and allowing estimations and simulations of the organism metabolism under varying physiological, chemical, and genetic conditions. It is also useful in principle to provide a systemic view of Isochrysis sp. metabolism, efficiently guiding research and granting context to omics data.

골-슬개건-골 및 슬괵건을 이용한 전방 십자 인대 재건술의 비교 - 술후 슬관절의 기능, 안정성 및 대퇴, 경골터널 확장정도에 대하여 - (A Comparison of the Results of BPTB and Hamstring ACL Autograft - Function, Stability & Tunnel Expansion -)

  • 정영복;태석기;임정일
    • 대한관절경학회지
    • /
    • 제4권1호
    • /
    • pp.1-6
    • /
    • 2000
  • 목적 : 자가이식건을 이용한 전십자인대 재건술에 있어서 골-슬개건-골과 슬괵건을 사용하고 그 결과를 서로 비교하고자 함에 있다. 대상 및 방법 : 1996년 1월부터 1999년 7월까지 골-슬개건-골을 이용한 군 32례, 슬괵건을 이용한 군 18례를 대상으로 하였고 평균 추시기간은 각 각 18 개월, 15 개월이었으며 기능, 안 정성 경골과 대퇴골 터널의 확장정도를 평가하였다. 결과 : 기능적인 평가에서 OAK(Orthopadishe Arbeitsguppe Knie) 점수는 슬개건을 사용한 군에서 술 전평균 71.6점$({\pm}10.0)$, 최종 추시점에서 88.5점$({\pm}7.9)$이었고 슬괵건을 사용한 군에서는 술 전 평균 73.9점$({\pm}11.5)$, 최종 추시점에서 82.5점$({\pm}12.9)$이었으며 IKDC(international Knee Documentation Committee)상 B군 이상의 결과를 보인 군은 슬개건을 사용한 경우 28례$(87\%)$, 슬괵건을 사용한 경우가 10례$(55\%)$였다. 안정성은 $KT-1000^{TM}$을 사용한 최대 도수 변이 검사에서 건측과 환측의 차이가 슬개건을 사용한 경우 술 전 평균6.5$({\pm}4.0)$mm, 최종 추시점에서 2.4$({\pm}1.8)$mm를, 슬괵건을 사용한 경우는 6.6$({\pm}2.9)$mm에서 2.3$({\pm}2.4)$mm를 보였다. 부하 방사선 사진상 전위는 각각 술 전 평균 8.0$({\pm}4.8)$mm, 7.0$({\pm}4.3)$mm에서 최종 추시점에서 2.8$({\pm}3.4)$mm, 2.8$({\pm}2.5)$mm의 차이를 나타냈다. 터널의 확장 정도는 대퇴골 터널의 경우에서 슬괵건을 사용한 군이 술 전 평균 9.6$({\pm}1.4)$mm, 최종 추시점에서 10.8$({\pm}1.0)$mm를 나타내어 슬개건을 사용한 경우보다 더 유의하게 확장되었다(p=0.03). 결론 : 두 군간에 술 후 안정성에서는 차이를 보이지 않아 슬개-대퇴 관절 동통, 골연령 및 미용상의 문제 등을 종합적으로 고려하여 이식건은 선택되어야하고, 터널확장을 줄이면 두 군의 안정성을 보다 향상시킬 수 있을 지는 대조군을 이용한 더 많은 연구가 필요할 것으로 보인다.

  • PDF

Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가 (Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator)

  • 김중현;이재성;김진수;이병일;김수미;정인순;김유경;이원우;김상은;정준기;이명철;이동수
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.445-455
    • /
    • 2005
  • 목적 : 임상용 Philips ARGUS 감마카메라와 특별 제작한 작은 구경의 바늘구멍조준기를 이용하여 animal SPECT를 개발하였다. 본 연구에서는 이 시스템의 물리적인 성능을 평가하고 소동물 실험에 적합한지를 평가하였다. 대상 및 방법: 스텝 모터와 이를 제어할 수 있는 소프트웨어를 이용한 피사체 회전장치를 개발하였다. 작은 입구(0.5, 1.0, 2.0 mm)의 바늘구멍조준기를 제작하였고 평면 공간해상도, 민감도, 단층촬영해상도 등을 포함한 물리적 성능을 모든 입구 크기에 대해 실험하였다. 조준기 입구로부터의 거리에 따른 사용 가능한 시야를 측정하기 위하여, 같은 간격만큼 떨어진 여러 선선원의 영상을 얻고 영상의 시야 내에서 보이는 선 영상의 개수를 이용하여 사용 가능한 시야를 측정하였다. 시야의 정중앙에 놓인 내경 0.5 mm, 길이 12 mm의 Tc-99m 선선원을 이용하여 거리에 따른 평면 공간 해상도를 측정하였다. 전체 반값두께를 'mm'단위로 얻기 위한 환산인자를 평면 영상에서의 두개의 서로 떨어진 선선원으로부터 계산하였다. 시스템 민감도를 측정하기 위하여 내경 1.0 mm의 Tc-99m 점선원을 사용하였다. 또한 냉소반점 모형과 열소반점 모형, 그리고 [I-123] FP-CIT를 정맥내 주사한 흰쥐의 뇌 영상의 SPECT 영상을 얻었고 여과후역투사 방법으로 재구성하였다. 결과: 사용 가능한 시야의 크기는 조준기의 초점으로부터의 거리에 비례하였고 이들의 관계는 선형 함수로 근사되었다(y=1.4x+0.5). 3 cm에서 1.0 mm 조준기로 측정한 민감도와 평면해상도는 각각 71 cps/MBq과 1.24 mm이었다. 1.0 mm 바늘구멍조준기에 대하여 [I-123] FP-CIT를 이용한 흰쥐의 뇌 SPECT 영상에서 각 반구의 줄무늬체 도파민 전달체 분포가 잘 구분되어 보였다. 결론: Philips ARGUS 스캐너와 작은 구경의 바늘구멍조준기로 개발한 새로운 소동물 SPECT 시스템이 소동물 영상을 얻는데 충분한 성능을 가짐을 입증하였다.

Brain PET에서 Truncated Region에 의한 영상의 질 평가 (Evaluation of Image Quality Change by Truncated Region in Brain PET/CT)

  • 이홍재;도용호;김진의
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.68-73
    • /
    • 2015
  • PET/CT 검사 시 검사 부위에 따라 적절한 액세서리의 사용이 권고되고 있다. 그 중 brain 검사에서 사용되는 액세서리인 brain holder를 사용하지 않는 경우 CT의 small FOV에 의하여 whole pallet이 AC-CT에 cover되지 않으며, 이에 따른 truncated region에 따라 count loss가 발생된다. 본 논문에서는 brain holder를 사용하지 않았을 경우 발생하는 truncated region에 의한 image quality의 변화를 평가하고자 한다. Siemens사의 biograph truepoint40 장비와 $^{68}Ge$-uniform phantom을 사용하여 $^{68}Ge$ phantom을 pallet위에서 스캔하고 brain holder위에 위치하고 스캔 하였다. brain protocol을 적용하여 holder를 사용하지 않은 경우 pallet이 AC-CT의 FOV에 포함되지 않는 것을 알 수 있었다. 획득된 영상을 FBP, OSEM, TrueX recon method를 이용하여 iteration 4, subsets 21, gaussian 2 mm와 5 mm parameter를 적용하여 재구성 후 Window level : -4200, window width : 1000으로 설정하여 영상의 uniformity를 평가하였으며, vertical profile을 생성하여 count uniformity를 평가하였고, 마지막으로 5장과 20장의 slice를 summation하여 integral uniformity를 평가하였다. AC-CT영상을 통하여 holder를 사용하지 않는 경우 FOV내에 pallet이 모두 포함되지 않는 것을 알 수 있으며, 이에 따른 truncation에 의한 부정확한 attenuation factor가 나타났다 PET corrected sinogram 영상에서 holder를 사용하지 않은 경우 truncated region에 의한 defect 부위를 확인할 수 있으며, holder를 사용한 경우 uniform한 영상을 확인할 수 있었다. Window level : 4200, window width : 1000으로 설정 시 FBP, OSEM, TrueX recon 방법 모두에서 holder를 사용한 경우 uniform한 영상이 획득되었지만, holder를 사용하지 않은 경우 하단에 defect가 관찰되었다. Holder를 사용한 경우와 사용하지 않은 경우의 영상을 각 5장, 20장씩 summation하여 NEMA method에 따라 integral uniformity를 구하였으며, 5장 slice의 summation에서 holder를 사용하지 않은 경우 11.7% holder를 사용한 경우 7.2%로 나타났다. 20장 slice의 summation에서 holder를 사용하지 않은 경우 11.1% holder를 사용한 경우 76.7%로 나타났다. brain 검사 시 holder를 사용하지 않는 경우 truncated region에 따른 phantom 하단부의 count defect가 확인되었으며, 이는 환자 검사 시 occipital lobe의 count loss를 발생하게 되며 research 검사 시 검사 결과의 오차를 발생하게 됨으로 brain PET/CT 검사 시 정확한 검사결과를 위하여 검사 액세서리가 반드시 적용되어야 할 것이다.

  • PDF

과도한 치관높이 공간을 가진 환자에서 유지관리를 고려한 임플란트 수복증례 (Implant restoration considering maintenance for a patient with excessive crown height space)

  • 마주리;양홍서;박상원;임현필;윤귀덕;방몽숙
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.107-112
    • /
    • 2013
  • 치관높이 공간이 과도할 경우 임플란트 몸체 혹은 구성물의 실패와 같은 고정성 보철물의 생역학적 합병증이 증가하며 치관 높이 공간이 12 mm 이상으로 과도한 경우는 고정성 보철물 선택에 유의하여야 한다. 고정성 보철물을 제작 시 치아들이 길어지므로 심미적 부위에서는 치은 색조를 띠는 재료를 사용해야 할 필요가 있다. 이러한 경우, 유지와 위생 관리가 적절하지 못하게 형성된 고정성 보철물은 음식물, 치태, 치석을 정체시키고 염증과 감염이 발생될 수 있으며 만성 염증과 감염으로 인해 외과적인 개선이 필요할 수 있다. 본 증례에서, 과도한 치관높이 공간을 가진 환자에게 발음 및 심미성을 고려하여 보철물 제작 후 보철물 주위의 치은 염증 및 부종이 발생하였으며, 그 원인이 구강위생을 어렵게 하는 보철물의 디자인으로 판단되어 치간공극을 충분히 형성한 임시 보철물을 장착 후 2개월 동안의 관찰 기간을 거치며 특이할 만한 이상 소견이 없음을 확인하였고 자가 위생 관리가 용이한 디자인으로 지르코니아 하부구조에 도재를 축성한 고정성 보철물로 구강회복을 시행하였으며, 일련의 치료과정을 통하여 부적절한 연조직 반응이 관찰 되지 않고 기능적인 면에서 만족스러운 결과를 얻을 수 있었다.

위전절제시 단순공장간치술의 임상적 의의 (Jejunal Interposition after Total Gastrectomy)

  • 배진선;노승무;정현용;이병석;조준식;신경숙;송규상;이태용
    • Journal of Gastric Cancer
    • /
    • 제1권4호
    • /
    • pp.210-214
    • /
    • 2001
  • Purpose: The aim of this study was to evaluate the shortterm outcome of a jejunal interposition, by comparing it with a conventional Roux-en-Y gastrojejunostomy, after a total gastrectomy. Materials and Methods: For 28 patients (20 men and 8 women) with a gastric adenocarcinoma, who underwent an isoperistaltic simple jejunal interposition, weight, hemoglobin, hematocrit, serum protein and albumin, and cholesterol levels were checked before the operation and at 1 year and 2 years after the surgery. Also, endoscopy was performed to confirm reflux esophagitis. In this study, the data were collected between January 1993 and July 1999 at Chungnam National University Hospital, and the results were compared with those of the Roux-en-Y procedure. Results: The body weights at 1 year and 2 years after the surgery had returned to $86.0\%$ and $87.6\%$ of the recent original body weight in the jejunal interposition (JI) group and to $90.8\%,\;87.0\%$, respectively in the Roux-en-Y (RY) group. The levels of hemoglobin (g/dl) were 13.3, 12.5, and 11.9 in the JI group, and 13.8, 12.6, and 12.1 in the RY group at the time of the operation and at 1 year, and 2 years after the surgery, respectively. The total serum protein (g/dl) levels were 7.1, 7.2, and 7.5 in the JI group and 7.1, 7.0, and 7.2 in the RY gropu at the time of the operation and at 1 year and 2 years after the surgery, respectively. The serum albumin (g/dl) levels were 4.2, 4.1, and 4.2 in the JI group and 4.2, 4.2, and 4.2 in the RY group at the time of the operation and at 1 year, and 2 years after the surgery, respectively. The total serum cholesterol (mg/dl) levels were 186.5, 174, and 164 in the JI group and 213.7, 171.1, and 141.0 in the RY group at the time of the operation and at 1 year and 2 years after the surgery, respectively. The endoscopic finding showed that reflux esophagitis occurred in $7.1\%$ of the patients in the JI group and in $3.5\%$ in the RY group. Conclusion: We think that from the view point of quality of life, a jejunal interposition, as well as a Roux-en-Y procedure, is a useful reconstruction methods for a total gastrectomy.

  • PDF