Study on the Image Analysis System of Nail-fold Capillary Vessel( I ) (인체를 대상으로 하는 혈허 혈어증 모델 개발을 위한 손톱 주름살의 모세혈관에 대한 영상장치 연구 ( I ))

  • Kim Gyeong Cheal;Hwang Won Deuk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.3
    • /
    • pp.789-791
    • /
    • 2004
  • We study on the video-capillaroscopy system for look a.t the nail fold capillary by the computer. This system is composed of the luminous source-producer, image-input, phase microscope. The method and contents of observation on this system are seperated from the image-analysis of nail fold capillary form-patterns and the currents of hematocytes. Therefore we think this system is possible to the practical clinic use for the basic model on the cardiac failure and the deficiency(血虛), stagnant(血瘀) of blood in human.

Development of Real-time Control System for White bBamline and Microprobe Beamline (백색광 및 X선 미세탐침 빔라인용 실시간 제어시스템 개발)

  • 윤종철;이진원;고인수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.748-751
    • /
    • 1997
  • The White Beamline of the Pohang Accelerator Laboratory(PAL) consists of main and second slits, a microprobe system, two ion chambers, a video-microscope, and a Si(Li) detector. These machine components must be controlled remotely through computer system to make user experiments precise and speedy. A real-time computer control system was developed to control and monitor these machine components. A VNIEbus computer with OS-9 real-time operating system was used for low-level data acquisition and control. VME I/O modules were used for step motor control and scaler control. The software has modular structure for maximum performance and easy maintenance. We developed database, I/O driver, and control software. We used PC/Window95 for data logging and operator interface. Visual C++ was used graphical user interface programming. RS232C was used for communication between VME and PC.

  • PDF

A Study on the shape deformation of ball projectile(5.56mm) under the low velocity impact (저속충격시 Ball 탄(5.56mm)의 형상변화에 관한 연구)

  • 손세원;이두성;홍성희;김영태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.865-868
    • /
    • 2002
  • This study investigated the shape deformation of ball projectile(5.56mn) under the low energy impact by the use of the drop weight impact tester. ball projectile(5.56mm) consisted of the copper face with a lead core. The impact conditions were changed with the variations of the mass and the drop height of the impact tup. Shape deformation of ball projectile(5.56mm) after low velocity impact was measured using a video microscope and CCD camera. The test result showed that impact energy by changing of drop height of the impact tup affected shape deformation of ball projectile(5.56mm). So, it is important to study the relativity between shape deformation of ball projectile(5.56mm) and ballistic protection of plate(such as hybrid composite laminates) under the high velocity impact.

  • PDF

Fabrication and Test of a Micro Pump with a Magnetostrictive diaphragm (자기변형 박막을 이용한 마이크로 펌프의 제작과 시험)

  • Seo, Jee-Hoon;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1017-1019
    • /
    • 1998
  • In this paper, the fabrication of a micropump with two giant magnetostrictive films of Sm-Fe and Tb-Fe is presented. The pump consist of one silicon wafer and one cover glass. The micropump consists of an actuator diaphragm, a paired nozzle and diffuser, and two through holes. The Structure of the micropump is fabricated by the chemical vapor deposition, the etching and the sputtering of the magnetostrictive films. The deflection of the actuator measured diaphragm is measured by using the laser vibrometer and the flow rate of the micro pump is observed by using a video microscope.

  • PDF

Comparative Quantification of Contractile Force of Cardiac Muscle Using a Micro-mechanical Force Sensing System

  • Ryu, Seok-Chang;Park, Suk-Ho;Kim, Deok-Ho;Kim, Byung-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1179-1182
    • /
    • 2005
  • To facilitate the cell based robot research, we presented a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source for potential application in a human body or blood vessels. The system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recoding system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitude of the contractile force of each cardiac myocyte on a different condition was compared. From the quantitative experimental results, we estimated that the force of cardiac myocytes is about $20{\sim}40\;{\mu}$N, and showed that there is difference between the control cells and the micro-patterned cells.

  • PDF

A Study on the Burning Characteristics of Composite Propellants at Low Pressure using Vacuum Strand Burner (Vacuum Strand Burner를 이용한 혼합형 추진제의 저압 연소특성 연구)

  • 김인철;유지창;박영규;이태호
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.39-45
    • /
    • 1994
  • Combustion characteristics of the solid composite propellants were studied from burning rate, ignition and steady combustion processes, and structure of the extinguished surfaces. Optical Vacuum Strand Burner (OVSB) system was desisted and configured to study those. Burning rates of the propellants were measured by OVSB at low pressure range by developed ten method. video camera(30 frames/s) was used to take potographs of the phenomena of ignition and combustion of propellant within the test cell of the OVSB. Burning surfaces of the propellants that were extinguished by rapid depressurization method were analyzed with Scanning Electron Microscope. (SEM).

  • PDF

Contractile Force Measurements of Cardiac Myocytes Using a Micro-manipulation System

  • Park Suk-Ho;Ryu Seok-Kyu;Ryu Seok-Chang;Kim Deok-Ho;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.668-674
    • /
    • 2006
  • In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about $20\sim40{\mu}N$, and show that there are differences between the control cells and the micro-patterned cells.

From Exoscope into the Next Generation

  • Nishiyama, Kenichi
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.3
    • /
    • pp.289-293
    • /
    • 2017
  • An exoscope, high-definition video telescope operating monitor system to perform microsurgery has recently been proposed an alternative to the operating microscope. It enables surgeons to complete the operation assistance by visualizing magnified images on a display. The strong points of exoscope are the wide field of view and deep focus. It minimized the need for repositioning and refocusing during the procedure. On the other hand, limitation of magnifying object was an emphasizing weak point. The procedures are performed under 2D motion images with a visual perception through dynamic cue and stereoscopically viewing corresponding to the motion parallax. Nevertheless, stereopsis is required to improve hand and eye coordination for high precision works. Consequently novel 3D high-definition operating scopes with various mechanical designs have been developed according to recent high-tech innovations in a digital surgical technology. It will set the stage for the next generation in digital image based neurosurgery.

Effect of the Electric Field on the Plant Protoplasts During Cell Fusion (세포융합시 전계하에서 식물세포가 받는 영향에 관한연구)

  • Lee, Sang-Hoon;Lee, Yon-Min;Cha, Hyeon-Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 1996
  • The objective of this paper is to investigate the effect of AC field on the protoplast of plant cells. The results of investigation will be the basis for the development of etectric cell fusion device. For the experiment, we made the electrode and AC and DC pulse generator and observed the behavior of the protoplasts through the inverted microscope which is connected to the monitor and video recorder by the CCD camera. As a result, the numbers of rotating, moving and destructed protoplasts and viability of the protoplasts have close relation to the amplitude of AC field, while the rotation rate is closely related to the frequency of AC pulse.

  • PDF

Preperation and properties of embossing treated fruit bagging paper (Embossing 처리 과대지의 제조 및 물성)

  • Kim, Kang-Jae;Byeon, Jong-Sang;Kim, Dae-Keun;Eom, Tae-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.11a
    • /
    • pp.201-206
    • /
    • 2006
  • Embossing treated fruit bagging paper was prepared with newly designed embossing roll and mechanical properties of fruit bagging paper were evaluated. The embossing technology was developed. First of all, embossing roll was designed in Ginyong Embo(Co) for the embossing process of fruiting bag. The embossing treated fruit bagging paper was manufactured in Agro(Co) at plant scale. The mechanical properties of embossing paper was investigated and operation efficiency of bagging was tested at field. The properties of embossed paper was quit satisfied for fruiting bag for cultivation of apple and pears.

  • PDF