• 제목/요약/키워드: vibration velocity

검색결과 1,403건 처리시간 0.027초

닭발 뼈 제거장치 개발에 관한 연구(2) - 뼈 제거장치 제작 및 성능시험 - (Studies on Development of a Chicken Feet-bone Remover (II) - Manufacture of Chicken Feet-bone Remover -)

  • 이정택;김태한
    • Journal of Biosystems Engineering
    • /
    • 제36권4호
    • /
    • pp.257-266
    • /
    • 2011
  • Consumption of chicken feet has been increasing recently, thus it was necessary to produce good quality of bone less chicken feet. In the process of bone removal during chicken feet production, feeding, conveying, cutting and bone removing process takes about 90% of overall labor. Therefore, the development of a chicken feet-bone remover was necessary to reduce the cost of labor. The main objective of this study was to make and test of chicken feet-bone remover. The optimum vibration level of feeder wes 8, and the optimum conveyor speed was 3.6 m/min. The feeding speed of feeder were 0.18 m/s, 0.13 m/s and 0.19 m/s for the weight ranges of chicken feet of >20 g, 20~30 g and 30 g< respectively. The sensing success rates of chicken feet were 100%, 98% and 96% for the conveyor speeds of 3.0, 3.6 and 4.2 m/min respectively. The slips of chicken feet were 1.0 mm, 1.9 mm and 3.2 mm for conveyor speed of 0.8, 1.9 and 4.2 m/min respectively, with the average moisture content of 65% (w.b). The incision accuracy rates of the chicken leg were 46%, 95%, 97% for the size ranges of >15 mm, 15~18 mm, 18 mm< respectively with the velocity of cutting blade 3.9 m/s. The removal rates of the chicken feet bone were 98%, 96%, 88% for toes diameter >10 mm, 10~15 mm, 15 mm> respectively with the velocity of cutting blade 11.8 m/s.

재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구 (Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention)

  • 양영진;이태호;오수훈
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Large Eddy Simulation of the flow around a finite-length square cylinder with free-end slot suction

  • Wang, Hanfeng;Zeng, Lingwei;Alam, Md. Mahbub;Guo, Wei
    • Wind and Structures
    • /
    • 제30권5호
    • /
    • pp.533-546
    • /
    • 2020
  • Large Eddy Simulation (LES) is used to study the effects of steady slot suction on the aerodynamic forces of and flow around a wall-mounted finite-length square cylinder. The aspect ratio H/d of the tested cylinder is 5, where H and d are the cylinder height and width, respectively. The Reynolds number based on free-stream oncoming flow velocity U and d is 2.78×104. The suction slot locates near the leading edge of the free end, with a width of 0.025d and a length of 0.9d. The suction coefficient Q (= Us/U) is varied as Q = 0, 1 and 3, where Us is the velocity at the entrance of the suction slot. It is found that the free-end steady slot suction can effectively suppress the aerodynamic forces of the model. The maximum reduction of aerodynamic forces occurs at Q = 1, with the time-mean drag, fluctuating drag, and fluctuating lift reduced by 3.75%, 19.08%, 40.91%, respectively. For Q = 3, all aerodynamic forces are still smaller than those for Q = 0 (uncontrolled case), but obviously higher than those for Q = 1. The involved control mechanism is successfully revealed, based on the comparison of the flow around cylinder free end and the near wake for the three tested Q values.

Seismic protection of the benchmark highway bridge with passive hybrid control system

  • Saha, Arijit;Saha, Purnachandra;Patro, Sanjaya Kumar
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.227-241
    • /
    • 2018
  • The present paper deals with the optimum performance of the passive hybrid control system for the benchmark highway bridge under the six earthquakes ground motion. The investigation is carried out on a simplified finite element model of the 91/5 highway overcrossing located in Southern California. A viscous fluid damper (known as VFD) or non-linear fluid viscous spring damper has been used as a passive supplement device associated with polynomial friction pendulum isolator (known as PFPI) to form a passive hybrid control system. A parametric study is considered to find out the optimum parameters of the PFPI system for the optimal response of the bridge. The effect of the velocity exponent of the VFD and non-linear FV spring damper on the response of the bridge is carried out by considering different values of velocity exponent. Further, the influences of damping coefficient and vibration period of the dampers are also examined on the response of the bridge. To study the effectiveness of the passive hybrid system on the response of the isolated bridge, it is compared with the corresponding PFPI isolated bridges. The investigation showed that passive supplement damper such as VFD or non-linear FV spring damper associated with PFPI system is significantly reducing the seismic response of the benchmark highway bridge. Further, it is also observed that non-linear FV spring damper hybrid system is a more promising strategy in reducing the response of the bridge compared to the VFD associated hybrid system.

수직 진동을 이용한 가열된 고체표면 위 증발하는 액적의 내부유동 제어연구 (Study of the Internal Flow and Evaporation Characteristic Inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface)

  • 박창석;임희창
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.37-46
    • /
    • 2017
  • 가열된 표면에서의 액적은 일반적으로 내부에 마랑고니 유동이 발생하고, 이는 불균일한 침전물 패턴 형상을 구성하게 된다. 본 연구는 마랑고니 유동을 가시화하고, 수직진동을 사용해서 이를 제어하는 것을 주 목적으로 한다. 액적이 증발하는 동안, 액적의 접촉각 변화와 부피변화를 실험적으로 알 수 있었고, PIV(Particle Image Velocimetry) 실험 장치를 이용하여, 평판 온도별 마랑고니 유동의 내부 유동의 흐름을 가시화하였다. 그리고 평판에 각 주파수별 수직진동을 가해주는 실험을 진행하여, 그 결과 마랑고니 유동의 유동 방향과 수직진동의 유동 방향이 서로 반대인 것을 확인할 수 있었다. 마지막으로 증발하는 액적에 수직진동을 가해줌으로써, 액적의 하단부분에서 내부유동의 흐름변화를 관찰하였다. 마랑고니유동에 의해 발생하는 내부유동 방향과 수직진동으로 발생하는 내부유동의 방향이 서로 반대 방향이므로 가열된 평판에 진동을 가해주었을 때 액적 내부유동의 흐름이 변화가 발생하였고, 이는 곧 불균일한 침전물 패턴이 억제된 것을 증발 후 침전물의 패턴형상을 통해 확인할 수 있었다.

서울 지하철공사 발파공법의 표준화 (Blasting Standardization works for NATM on the Seoul Subway Construction by Dr, Ginn Huh)

  • 허진
    • 기술사
    • /
    • 제16권3호
    • /
    • pp.5-23
    • /
    • 1983
  • On the Seoul Metropolitan Subway Construction of No. 3, 4 Line, the total length is 57 Km and it is now undergoing almost 55% progress. The working method is classified into Open Cut of 70% and the rest of 30% tunnelling method in the 48 job site. Above tunnelling method is execute by American Steel Support System and the rest of 10 job site carried out by New Austria Tunnelling Method. This paper describes Blasting Standardizations works on the above Tunnelling ' Open Cut Method under big slogan, first safety, second execution. As a superintendent, I strived standardization of works with Better powder, Better Drills ' Better Pattern. Geological structure of Seoul area is composed by Jurassic Granite and also the above rockgroup are over burden by Alluviums as a Unconformity. First of all, I carried out the standard amount of powder and burden through experimental standard blasting by each powder as following Blasting works in the subway construction is surrounding shop Building, under pass the city river and also under pass highest building basement floor. I made allowable Blasting Vibration Value by West-Germany Vornorm DIN 4150, Teil 3 and should measure each blasting works as fellows all of powder is used basically Low-Gravity and Low Velocity such as Slurry, Ammonium Nitrate ' Finex I, II. for Smooth Blasting Instead of Gelatin Dynamite. Electric Detonation Cap is used basically M/S Delay Cup instead of Electric delay ' Simultaneous cap. I applied following formula V=KW3/4 $D^{-2}$ V=Particle Velocity (Cm/sec) K=Ginh Huh's Value W=Delay Charge (Kg) D=Distance(m) In the Open Cut, within 1m distance from H-pile I made to use the Concrete breaker, as following V=7W/$^{0.5}$V/$^{-1.75}$ On the Concentrate Building area, I advise to use Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.e Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.

  • PDF

Effectiveness of whole body vibratory stimulation for fall prevention in super-aged women: a preliminary randomized trial

  • Kim, Byeong-Soo;Lim, Kang-Uk;Baek, In-Seon;Kim, Min-Kyoung;Kang, Hye-Min;Nam, Gi-Jeong;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권1호
    • /
    • pp.32-39
    • /
    • 2019
  • Objective: The aim of this study is to investigate the effects of whole body vibratory stimulation on muscle strength, balance, and fall efficacy among super-aged women. Design: Randomized controlled trial. Methods: Twenty-eight super-aged women over 80 years of age were assigned to either the experimental group (n=14) and control group (n=14). The experimental group received an exercise program that used the whole body vibratory stimulation with a frequency of 30 Hz and amplitude of 3 mm, and the control group received an exercise program without vibratory stimulation. Intervention was provided for 4 weeks, 3 sessions per week, and 30 minutes per session. In order to measure lower extremity muscle strength the 30-second chair stand test (CST) was used. The Berg Balance Scale (BBS) was used to measure dynamic balance. Static balance was measured by tracking the path length, velocity, and area of the center of pressure (CoP). The Falls Efficacy Scale (FES) was used to measure the subjects' fear of falling. Results: Both the experimental and control group demonstrated statistically significant increase in muscle strength, dynamic balance, and fall efficacy (p<0.05). Only the experimental group showed significant improvements in static balance before and after the intervention (p<0.05). The experimental group showed significantly greater improvements in CST, BBS, and CoP (path length, velocity) than control group (p<0.05). Conclusions: Whole body vibratory stimulation exercise is shown to be a safe and appropriate physical therapy intervention method to enhance muscle strength, balance, and fall efficacy of super-aged women.

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • 제32권5호
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

상용차량의 브레이크 시스템과 차량 시스템 주파수 분석을 통한 브레이크 저더의 실험적 고찰 (An Experimental Study on Brake Judder via the Frequency Analysis of the Brake System and Vehicle System of a Commercial Vehicle)

  • 문일동;김종대;오재윤
    • 대한기계학회논문집A
    • /
    • 제31권12호
    • /
    • pp.1131-1138
    • /
    • 2007
  • This paper studies experimentally on the building-up process for the amplitude of a commercial truck vibration induced by brake judder. A front axle drum equipped with a drum brake system is utilized for this experiment. A brake dynamo test, a real vehicle ride test and a real vehicle braking test are performed for the analysis of brake judder. The brake dynamo test measures judder by applying brake chamber pressures of 1, 2 and 3 bar at initial brake pad temperatures of $100^{\circ}C$ and $150^{\circ}C$. In order to assess the vertical acceleration at the front axle, the real vehicle ride test on a straight test road with velocities of 20, 40, 60 and 80 km/h is performed. The real vehicle braking test is carried out at the deceleration rate of 0.2g from a velocity of 90km/h for evaluating the vertical, lateral and longitudinal accelerations both at the front axle and at the cab floor under the driver's seat. The magnitudes and frequencies of the measured peak accelerations from the brake dynamo test, the real vehicle ride test and the real vehicle braking test are comparatively analyzed. This paper shows that the vibration produced by brake judder is built up due to the brake system's peak acceleration frequency being close to the vehicle ride mode's frequency.

소음예측 비례식을 이용한 자동차 엔진 공회전 속도 제어 장치 유로의 저소음 디자인 (Low-Noise Design of Passage of Idle Speed Control Actuator in Automotive Engines Using Scaling Laws for Noise Prediction)

  • 정철웅;김재헌;박용환;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.283-290
    • /
    • 2007
  • Recently, plastic products in air-intake parts of automotive engines have become very popular due to advantages that include reduced weight, constricted cost, and lower intake air temperature. However, flow-induced noise in air-intake parts becomes a more serious problem for plastic intake-manifolds than for conventional aluminum-made manifolds. This is due to the fact that plastic manifolds transmit more noise owing to their lower material density. Internal aerodynamic noise from an Idle Speed control Actuator (ISA) is qualitatively analyzed by using a scaling law, which is expressed with some flow parameters such as pressure drop, maximum flow velocity, and turbulence kinetic energy. First, basic flow characteristics through ISA passage are identified with the flow predictions obtained by applying Computational Fluid Dynamics techniques. Then, the effects on ISA passage noise of each design factors including the duct turning shape and vane geometries are assessed. Based on these results, the preliminary low noise design for the ISA passage are proposed. The current method for the prediction of internal aerodynamic noise consists of the steady CFD and the scaling laws for the noise prediction. This combination is most cost-effective, compared with other methods, and therefore is believed to be suited for the preliminary design tool in the industrial field.

  • PDF