• Title/Summary/Keyword: vibration performance test

Search Result 918, Processing Time 0.039 seconds

Development of a Direct Drive Type Exciter and Performance Evaluation (직접구동형 가진기의 개발 및 성능평가)

  • Kim, O-Bok;Park, Jung-Mo;Kim, Seock-Hyun
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.329-334
    • /
    • 1998
  • The purpose of this study is to design and manufacture a vibration exciter, which can be used in the education and research for the vibration engineering. For this purpose, a direct drive type vibration exciter is developed, which consists of a motor, an inverter, eccentric rotating sleeves and two excitation plates. Developed exciter is tested on some dynamic characteristics to evaluate its excitation performance. Test results show that the developed machine can excite bodies on the horisontal vibrating plates in x,y direction by the constant displacement amplitude in the frequency range below 50Hz, which confirm that the exciter can be used as a vibration testing machine in the low frequency range.

  • PDF

Comparison of Performance of the Exciter and Impact Hammer Test for Dynamic Characteristics Analysis of Floor Slabs (건물바닥 슬래브의 동특성 분석을 위한 가진기와 Impact Hammer의 성능 비교)

  • Ahn, Sang-Kyung;Moon, Yeong-Jong;Oh, Jung-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.117-120
    • /
    • 2007
  • The floor slabs of building structures are often subjected to the periodic force which is induced by vibrating machines or human activity(walking, jumping, running etc). These periodic forces cause excessive oscillation. In order to examine the dynamic characteristics of floor slabs, the dynamic characteristics test is accomplished. Generally, the Impact Hammer and Dynamic Exciter test is used to dynamic characteristics test. But the Impact Hammer test is not suitable to apply in building slabs. In this paper, It compared the performance of the Exciter and Impact Hammer test for dynamic characteristics analysis of floor slabs.

  • PDF

Control Method of Wind Induced Vibration Level for High-rise buildings (초고층 건물의 풍가속도응답 조절 기법)

  • Kim Ji-Eun;Seo Ji-Hyun;Park Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.375-382
    • /
    • 2005
  • In this paper, a practical control method of wind-induced vibration of high-rise buildings is presented in the form of resizing algorithm. In the structural design process for high-rise buildings, the lateral load resisting system for the building is more often determined by serviceability design criteria including wind-induced vibration level. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. The performance of the proposed method is evaluated by comparing wind-induced vibration levels estimated both from approximate techniques and wind tunnel test.

  • PDF

A Draft Korean Standards on the Evaluation Method of Airborne Sound Insulation in Building and Building Elements (공기음 차단성능 평가방법의 KS규격화 방안)

  • 양관섭;이태강;이근희;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.387-391
    • /
    • 2001
  • In evaluating sound performance of building, it is important to carry on tests and evaluations based upon residential sound performances. Korean Standards include test methods on sound performance, but don't include any code on evaluation methods. Therefore, evaluation methods from Japan or ISO have been used for evaluating sound performance in domestic so far. In this study, a draft of Korean Standards on a sound performance evaluation method in buildings is proposed.

  • PDF

Experimental and numerical simulation investigation on vortex-induced vibration test system based on bare fiber Bragg grating sensor technology for vertical riser

  • Wang, Chunxiao;Wang, Yu;Liu, Yu;Li, Peng;Zhang, Xiantang;Wang, Fei
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.223-235
    • /
    • 2021
  • The Vortex-Induced Vibration (VIV) test system on deepwater riser based on Bare Fiber Bragg Grating (BFBG) sensor technology was designed. Meanwhile, a riser VIV response numerical model was established based on the work-energy principle. The results show that the first-order vibration frequency dominates the vibration of the riser, and as the velocity increases, the dominant frequency of the riser gradually increases under the effect of different top tensions. At the same velocity, as the top tension increases step by step, the dominant frequency and fatigue damage at the same position along the axial length of the riser both gradually decreases. The model test and numerical simulation show a relatively consistent change, maintaining a high degree of agreement. The process control system based on BFBG of model test has excellent performance, and FBG sensors have great advantages in VIV test of a vertical riser in water.

A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad (스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Eum, Ki-Young;Jang, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

Development and Performance Validation of Integrated Bus Electronic Unit for Small Satellite (소형위성용 통합형 전장박스의 개발 및 성능검증)

  • Chang, Jin-Soo;Kim, Dong-Woon;Kang, Suk-Jin;Lee, Byung-Hoon;Moon, Byoung-Young;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.353-362
    • /
    • 2007
  • Unlike large satellites, small satellites, such as nanosatellite and microsatellite, can provide a limited interior space for components mounting. In order to mitigate this issue, the compact Bus Electronic Unit(BEU) that integrates satellite electronic modules, combining most of bus subsystems and payload electronic modules into one unit, has been developed for HAUSAT-2 nanosatellite. This paper addresses the design and environmental test result analyses of BEU. The vibration and thermal vacuum tests were conducted at qualification level for the verification of design margin of newly developed BEU. The performance of individual electronic subsystem modules has been verified through performance tests before and after the qualification tests. It was confirmed that the natural frequency of BEU satisfies the design stiffness requirement without structural damage in the vibration test. Thermal analysis results were also almost consistent with test results through modified thermal analysis modeling.

Vibration Monitoring of a 1kW Small Wind Turbine Generator (1kW소형 풍력발전기의 진동 모니터링)

  • Kim, Seock-Hyun;Nam, Y.S.;Yoo, N.S.;Kim, Yun-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.308-311
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

Attention Degradation of Occupant Driving Vehicle on Cross-country Test Road According to Vibration Exposure Time (야지 시험로 주행 진동 노출 시간에 따른 탑승자의 주의력 저하에 관한 연구)

  • Park, Dong-Jun;Choi, Moon-Gee;Song, Jong-Tak;Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.155-161
    • /
    • 2017
  • When a military vehicle is driven on a cross-country road, the occupants are exposed to vibration at a body resonance. In case that the exposure continues for too long period, the attention ability of the occupant could be affected by the vibration exposure. In the study, it was experimentally tried to find if there is a correlation between degradation of attention and vibration exposure. Two kinds of test among various psychological attention tests were employed, which were selected with considering a situation of carrying out military mission on vehicle. At the result, the searching test for controlled attention showed significant degradation in the accuracy and performance time in case of exposure at the vibration. And the attention degradation appeared to be greater when the vibration exposure increases. The dual task test for divided attention showed the difference between vibration and non-vibration condition, but showed it is insignificant for the attention to degrade by increasing exposure time.

A Behavior Test on a Frictional-Wedge-Type Vibration Isolation Device for Vibration Reduction of a Railway Track (열차 진동 저감을 위한 마찰쐐기형 방진장치의 거동 시험)

  • Lee, Chanyoung;Choi, Sanghyun;Lee, Yooin;Kwon, Segon;Koh, Yongsung;Ji, Yongsoo
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2015
  • In the case of railway facilities in cities such as a railway station or a bridge, the significance of design for reducing vibration and noise is getting more significant. The vibration control solution is in need especially for an elevated railway station to block vibration of a train and secondary noise effectively. Even though a vertical vibration isolation device is able to be applied effectively to railway facilities such as elevated railway stations which transfer vibration directly from a train to a structure, the development of the vertical device is much slower than a horizontal vibration isolation device. In this paper, a vibration isolation device using wedge type friction material which is currently developing to reduce train-induced vibration effectively is introduced and test results for verification of dynamic performance is also presented. The vibration test on a concrete structure equipped with the developed vibration isolation device is conducted through which the isolation performance and dynamic properties are verified and needs for improving the performance of the device is identified.