• 제목/요약/키워드: vibration mitigation of cable

검색결과 37건 처리시간 0.023초

Vibration mitigation of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Sun, Limin;Jiang, Xiaolu
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.35-53
    • /
    • 2012
  • Mechanical dampers have been proved to be one of the most effective countermeasures for vibration mitigation of stay cables in various cable-stayed bridges over the world. However, for long stay cables, as the installation height of the damper is restricted due to the aesthetic concern, using passive dampers alone may not satisfy the control requirement of the stay cables. In this connection, semi-active MR dampers have been proposed for the vibration mitigation of long stay cables. Although various studies have been carried out on the implementation of MR dampers on stay cables, the optimal damping performance of the cable-MR damper system has yet to be evaluated. Therefore, this paper aims to investigate the effectiveness of MR damper as a semi-active control device for the vibration mitigation of stay cable. The mathematical model of the MR damper will first be established through a performance test. Then, an efficient semi-active control strategy will be derived, where the damping of MR damper will be tuned according to the dynamic characteristics of stay cable, in order to achieve optimal damping of cable-damper system. Simulation study will be carried out to verify the proposed semi-active control algorithm for suppressing the cable vibrations induced by different loading patterns using optimally tuned MR damper. Finally, the effectiveness of MR damper in mitigating multi modes of cable vibration will be examined theoretically.

Experimental investigation on multi-mode vortex-induced vibration control of stay cable installed with pounding tuned mass dampers

  • Liu, Min;Yang, Wenhan;Chen, Wenli;Li, Hui
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.579-587
    • /
    • 2019
  • In this paper, pounding tuned mass dampers (PTMDs) were designed to mitigate the multi-mode vortex-induced vibration (VIV) of stay cable utilizing the viscous-elastic material's energy-dissipated ability. The PTMD device consists of a cantilever metal rod beam, a metal mass block and a specially designed damping element covered with viscous-elastic material layer. Wind-tunnel experiment on VIV of stay cable model was set up to validate the effectiveness of the PTMD on multi-mode VIV mitigation of stay cable. By analyzing and comparing testing results of all testing cases, it could be verified that the PTMD with viscous-elastic pounding boundary can obviously mitigate the VIV amplitude of the stay cable. Moreover, the installed location and the design parameters of the PTMD device based on the controlled modes of the primary stay cable, would have a certain extent suppression on the other modal vibration of the stay cable, which means that the designed PTMDs are effective among a large band of frequency for the multi-mode VIV control of the stay cable.

MR damping system for mitigating wind-rain induced vibration on Dongting Lake Cable-Stayed Bridge

  • Chen, Z.Q.;Wang, X.Y.;Ko, J.M.;Ni, Y.Q.;Spencer, B.F.;Yang, G.;Hu, J.H.
    • Wind and Structures
    • /
    • 제7권5호
    • /
    • pp.293-304
    • /
    • 2004
  • The Dongting Lake Bridge is a cable-stayed bridge crossing the Dongting Lake where it meets the Yangtze River in southern central China. Several intensive wind-rain induced vibrations had been observed since its open to traffic in 1999. To investigate the possibility of using MR damping systems to reduce cable vibration, a series of field tests were conducted. Based on the promising research results, MR damping system was installed on the longest 156 stay cables of Dongting Lake Bridge in June 2002, making it the worlds first application of MR dampers on cable-stayed bridge to suppress the wind-rain induced cable vibration. As a visible and permanent aspect of the bridge, the MR damping system must be aesthetically pleasing, reliable, durable, easy to maintain, as well as effective in vibration mitigation. Substantial work was done to meet these requirements. This paper describes field tests and the implementation of MR damping systems for cable vibration reduction. Three-years reliable service of this system proves its durability.

Analysis of dynamic behavior for truss cable structures

  • Zhang, Wen-Fu;Liu, Ying-Chun;Ji, Jing;Teng, Zhen-Chao
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.117-133
    • /
    • 2014
  • Natural vibration of truss cable structures is analyzed based upon the general structural analysis software ANSYS, energy variational method and Rayleigh method, the calculated results of three methods are compared, from which the characteristics of free-vibration are obtained. Moreover, vertical seismic response analysis of truss cable structures is carried out via time-history method. Introducing three natural earthquake waves calculated the results including time-history curve of vertical maximal displacement, time-history curve of maximal internal force. Variation curve of maximal displacement of node along span, and variation curve of maximal internal force of member along span are presented. The results show the formulas of frequencies for truss cable structures obtained by energy variational method are of high accuracy. Furthermore, the maximal displacement and the maximal internal force occur near the 1/5 span point. These provide convenient and simple design method for practical engineering.

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

사장교의 케이블 진동저감을 위한 수동 제어시스템 (Passive Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges)

  • 황인호;이종세
    • 대한토목학회논문집
    • /
    • 제26권5A호
    • /
    • pp.881-885
    • /
    • 2006
  • 사장교 케이블은 구조적으로 휨강성과 감쇠력이 작아 풍우에 의해 쉽게 유해진동이 발생한다. 이러한 풍우진동을 저감시키기 위한 효과적인 방법으로 부가댐퍼를 장착하여 케이블의 감쇠력을 증가시키는 제어시스템이 널리 사용되어왔다. 그러나 사장교의 장대화로 인해 구조적으로나 미적으로 충분한 감쇠력을 제공할 수 있는 위치에 부가댐퍼를 장착하기 어렵게 되었다. 그러므로 본 논문은 사장교의 미관을 해치지 않으면서 기존의 제어시스템보다 효과적으로 케이블의 진동을 저감시킬 수 있는 새로운 개념의 제어시스템을 제안하였다. 제안된 시스템은 케이블 앵커리지에 적층고무베어링과 같은 유동이 가능한 장치와 내부댐퍼로 구성되었으며, 제어성능평가를 위해 해석모델을 개발하였다. 제안된 시스템의 제어성능 분석을 위해 수치해석을 수행하였으며 기존의 부가 댐퍼시스템과 진동 저감효과를 비교하였다. 제안된 제어시스템은 기존의 부가댐퍼 시스템 보다 효과적으로 진동을 저감시킬 수 있었으며 사장교 케이블의 풍우진동 저감을 위해 효과적인 시스템으로 사료된다.

Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템 (Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag)

  • 황인호;박준형;이종세
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.657-664
    • /
    • 2008
  • 사장교 케이블은 구조적으로 휨강성과 감쇠력이 작아 풍우에 의해 쉽게 유해진동이 발생한다. 이러한 풍우진동을 저감시키기 위한 효과적인 방법으로 부가댐퍼를 장착하여 케이블의 감쇠력을 증가시키는 제어시스템이 널리 사용되어왔다. 그러나 사장교의 장대화로 인해 구조적으로나 미적으로 충분한 감쇠력을 제공할 수 있는 위치에 부가댐퍼를 장착하기 어렵게 되었다. 최근 본 저자는 사장교의 미관을 해치지 않으면서 기존의 제어시스템보다 효과적으로 케이블의 진동을 저감시킬 수 있는 새로운 개념의 사장교 케이블 진동 제어시스템을 제안하였다. 본 논문에서는 기존의 연구를 확장하여 새그(Sag)를 고려한 Movable anchorage 시스템을 제안하였으며, 수치해석을 통한 제어성능을 평가하였다. 수치해석의 결과 제안된 시스템은 새그를 고려하였을 때에도 고려하지 않은 경우와 마찬가지로 베어링장치의 강성이 작을수록 기존의 비감쇠 시스템이나 일반적인 수동제어시스템보다 훨씬 좋은 성능을 나타내었다. 제안된 시스템에 있어서 최적의 제어성능을 제공하기 위해서는 새그의 크기를 고려해서 최적의 감쇠계수를 결정해야 할 것으로 사료된다.

Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations

  • Wang, Zhi-hao;Gao, Hui;Xu, Yan-wei;Chen, Zheng-qing;Wang, Hao
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.83-94
    • /
    • 2019
  • Passive negative stiffness dampers (NSDs) that possess superior energy dissipation abilities, have been proved to be more efficient than commonly adopted passive viscous dampers in controlling stay cable vibrations. Recently, inertial mass dampers (IMDs) have attracted extensive attentions since their properties are similar to NSDs. It has been theoretically predicted that superior supplemental damping can be generated for a taut cable with an IMD. This paper aims to theoretically investigate the impact of the cable sag on the efficiency of an IMD in controlling stay cable vibrations, and experimentally validate superior vibration mitigation performance of the IMD. Both the numerical and asymptotic solutions were obtained for an inclined sag cable with an IMD installed close to the cable end. Based on the asymptotic solution, the cable attainable maximum modal damping ratio and the corresponding optimal damping coefficient of the IMD were derived for a given inertial mass. An electromagnetic IMD (EIMD) with adjustable inertial mass was developed to investigate the effects of inertial mass and cable sag on the vibration mitigation performance of two model cables with different sags through series of first modal free vibration tests. The results show that the sag generally reduces the attainable first modal damping ratio of the cable with a passive viscous damper, while tends to increase the cable maximum attainable modal damping ratio provided by the IMD. The cable sag also decreases the optimum damping coefficient of the IMD when the inertial mass is less than its optimal value. The theoretically predicted first modal damping ratio of the cable with an IMD, taking into account the sag generally, agrees well with that identified from experimental results, while it will be significantly overestimated with a taut-cable model, especially for the cable with large sag.

현이론을 이용한 사장교 케이블 장력산정 (Estimation of Stay Cable Tension Using String Vibration Theory)

  • 박연수;최선민;이병근;김민중
    • 한국방재학회 논문집
    • /
    • 제9권2호
    • /
    • pp.17-22
    • /
    • 2009
  • 사장교 케이블 장력 산정 방법에는 직접적인 방법과 간접적인 방법이 있는데 직접적인 방법은 정확성에 문제가 있을 뿐만 아니라 제한사항도 많다. 따라서 일반적으로 케이블 장력 추정은 간접적인 방법인 고유진동수를 이용하는 진동법을 사용하고 있다. 최근 시공된 사장교의 케이블에 대해 현이론을 이용한 진동법으로 케이블 장력을 산정해 그 결과를 다중진동모드를 이용한 진동법과 비교했다. 그 결과를 요약하면, 현이론 방법의 오차는 7차이하의 진동모드에서는 2%를 초과하지 않았다. 특히, 3차와 4차 진동모드의 오차는 1%를 초과하지 않았다. 그리고 진동모드의 차수가 증가하고 케이블 단면이 클수록 오차는 증가했고, 장력이 크고 케이블 길이가 길수록 오차는 낮아짐을 알 수 있었다. 즉 7차 이하의 진동모드에서 높은 정밀도를 갖는 다는 것을 알 수 있다.

강합성 단면을 가진 사장교의 와류진동 발생 예측 (Prediction of Vortex-induced Vibration of the Cable-Stayed Bridge with Steel Composite Deck)

  • 조재영;조영래;이학은
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.449-453
    • /
    • 2007
  • After over a century of effort by researchers and engineers, the problem of bluff body flow, in particular vortex shedding frequency, remains almost entirely in the empirical, descriptive realm of knowledge. Computational methods have been systematically applied for vortex-induced vibrations of the cable-stayed bridge with steel composite deck by unsteady wind loadings due to vortex-shedding. The focus of this paper is to predict the vortex-induced vibration of the cable-stayed bridge with steel composite deck based computational fluid dynamics(CFD).

  • PDF