• 제목/요약/키워드: vibration

검색결과 25,159건 처리시간 0.041초

회전축 정렬불량 광디스크 드라이브의 진동 저감에 관한 연구 (A Study on Vibration Reduction of an Optical Disk Drive with the Misaligned Axis of Rotation)

  • 강봉진;정태은;신효철;오주환
    • 한국정밀공학회지
    • /
    • 제21권5호
    • /
    • pp.122-130
    • /
    • 2004
  • In a high-speed and wide operating field optical disk drive, the vibration problem is one of the most important factors to be considered for reliable performance. And a disk misaligned with axis of rotation is a major source of vibration in optical disk drive. Furthermore, this vibration disturbance of the disk spindle system causes failure in the reading and writing process. So to solve this vibration problem, the vibration absorber using rubber mount has been introduced in recent years. In this paper, we have analyzed the simple optical disk drive model with dynamic vibration absorber through dynamic analysis of 12-dof by Recurdyn program and obtained optimal mass and frequency ratios of dynamic vibration absorber of dynamic vibration absorber and the optimal frequency ratio.

Experimental Investigation of the Effect of Lead Errors on Helical Gear and Bearing Vibration Transmission Characteristics

  • Park, Chan-Il;Lee, Jang-Moo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1395-1403
    • /
    • 2002
  • The characteristics of gear meshing vibration undesgo change as the vibration is transmitted from the gear to the housing. Therefore, vibration transmission characteristics of helical gear systems must be understood before the effective methods of reducing gear noise can be found. In this work, using a helical gear with different lead errors, the gear vibration in the rotational direction and the bearing vibration are measured. The frequency characteristics of gear and bearing vibration are investigated and a comparson is also provided.

경부선 철도진동의 특성과 영향범위 (Characteristic and Propagation of Railroad Vibration in Kyoungbu Line)

  • 유승도;신동석;설증민;강대준;박준철;이재인
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.597-604
    • /
    • 1997
  • Ground vibrations induced from railroad were measured to get the basic data that can be usde to prepare countermeasures for solving environmental vibration problems. Vibration levels were measured simultaneously at three points in double distances from railroad. These data were analuzed with the kinds of trains, media to understand the magnitudes and characteristics of distance attenuation of railroad vibrations.

  • PDF

전신진동이 인간성능에 미치는 영향 (Effects of whole-body vibration on human performance)

  • 이남식;박세진;김철중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1990년도 추계학술대회논문집; 한양대학교, 서울; 24 Nov. 1990
    • /
    • pp.91-98
    • /
    • 1990
  • This paper reviews the previous researches related to the effects of whole-body vibration on human performance. The physiological effects of vibration were reviewed in the first part, and the effects of vibration on vision and manual control performance were discussed. the relationships between vibration and ride quality were also discussed. ISO-2631 was briefly reviewed, and cautions and limitations were discussed to avoid misinterpretations when we accomodate Korean population to this standard. Further researches were recommended to get better understanding of response characteristics of Korean to whole-body vibration.

  • PDF

양단고정보에서 진동저감을 위한 분포질량 동흡진기의 설계 (Design of Distributed Mass Dynamic Vibration Absorber(DVA) for vibration reduction of Fixed-Fixed Beam)

  • 윤정민;정운창;김진수;이유엽;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.34-35
    • /
    • 2014
  • we designed a distributed mass dynamic vibration absorber for vibration reduction in a dual mode system. And we were subjected to evaluation of the vibration reduction performance of the distributed mass dynamic vibration absorber through experiments.

  • PDF

실험적 모우드 해석을 이용한 방사광 가속기 건물의 진동제어 (VIBRATION CONTROL OF SYNCHROTRON LIGHT SOURCE BUILDING USING EXPERIMENTAL MODAL ANALYSIS)

  • 박상규;이홍기;권형오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 추계학술대회논문집; 반도아카데미, 26 Nov. 1993
    • /
    • pp.157-161
    • /
    • 1993
  • Optical devices and electronic equipments used in the laboratory of the synchrotron light source building of the accelerator have stringent vibration limits. In order to control the vibration of the building structure and HVAC systems which are main vibration sources are evaluated using experimental modal analysis. Double anti-vibration system is used for the HVAC system and results show that the double anti-vibration system reduces the vibrations of the building to acceptable levels.

  • PDF

선박 추진축계의 2절 비틀림진동에 기인한 주기관 X-모드 진동 현상의 연구 (A Study on Main Engine X-mode Vibration Phenomenon due to 2nd Node Torsional Vibration of the Marine Propulsion System)

  • 이돈출;김준성;김진희
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.806-813
    • /
    • 2013
  • For the past years, higher power rating 2 stroke super long stroke diesel engines having more than 8 cylinders and larger cylinder bore are installed mainly on very large containerships to save on fuel consumption. However, these engines are prone to X-mode vibration due to 2nd node torsional vibration or the X-type moment, particularly because of the increase in total length and height. Recently, cases of excessive X-mode vibration often occurred on engine's major components. This vibration is manifested also as secondary vibration causing failure in engine-mount large structures. This study investigated the excitations caused by the 2nd node propulsion shafting torsional vibration that influence X-mode vibration of the main engine and practical countermeasures are proposed. An 8RT-flex82T 8 cylinder engine and 11S90ME-C 11 cylinder engine for a container ship was used as research model.

디젤기관 추진축계의 연성진공에 관한 연구(제2보 : 강제 감쇠 연성진동해석) (Studies on Coupled Vibrations of Diesel Engine Propulsion Shafting(2nd Report: Analyzing of Forced Vibration with Damping))

  • 전효중;이돈출;김의간;김정렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.563-572
    • /
    • 2001
  • With the results of calculation for natural frequencies the reponses of forced coupled vibration of propulsion shafting system were investigated by the modal analysis method. For the forced vibration response analysis, the axial exciting forces, the axial damper/detuner, propeller exciting forces and damping coefficients were extensively considered. As the conclusion of this study, some items are cleared as follows.-The torsional vibration amplitudes are not influenced by the radial excitation forces of the crank shaft. -The axial vibration amplitudes are influenced by the tangential exciting forces as well as the radial exciting forces of the crank shaft. The increase of the amplitudes is observed in the speed range at the neighbourhood of any torsional critical speed. 1The closer the torsional and axial critical speed. the larger coupling effect becomes. -The axial exciting force of propeller is relatively strong comparing with axial exciting forces of cylinder gas pressure and oscillating inertia of reciprocating mechanism. Therefore, the following conclusions are obtained. -Torsional vibration calculation with the classical one dimensional model is still valid. -The influence of torsional excitation at each crank upon the axial vibration is improtant. especially in the neighbourhood of a torsional critical speed. That means that the calculation of axial vibration with the classical one dimensional model is inaccurate in most of cases.

  • PDF

가속도 크기 변수에 따른 수직진동에 대한 인지수준 고찰 (Investigation for the Characters of Human Perception Level according to Acceleration Value Parameters)

  • 이민정;한상환
    • 한국소음진동공학회논문집
    • /
    • 제24권9호
    • /
    • pp.731-740
    • /
    • 2014
  • Occupants induced floor vertical vibrations may cause other occupant's annoyance and lead to social loss. To help control such floor vibrations, several criteria have been developed mostly based on human perception tests and floor vibration tests. Floor vibration is evaluated by comparison with criteria and vibration parameters of subject floor, such as frequency, damping ratio, acceleration value, vibration duration time and occurrence frequency. Three acceleration value parameters are used in criteria; peak acceleration, rms acceleration and VDV, when a floor vibration serviceability is evaluated. Meanwhile rms acceleration and peak acceleration are adopted as vibration limit value in criteria and researches of human perception for vibration. Occupants induced floor vibration is transient rather than steady state. However, rms acceleration is not reliable parameter for evaluating transient vibration. The objective of this study is to investigate the characters of human perception level according to acceleration value parameters for vibration induced by heel impacts and walking activities.

KTX 운행에 따른 가선설비 유리애자의 진동특성과 파손 가능성 검증 (The Verification of Breakage Possibility and Vibration Properties of Glass Insulators by the High-speed Railway Service)

  • 김영석;송길목;정진수;전용주
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.566-572
    • /
    • 2009
  • This paper has studied breakage possibility of glass insulators by resonance and accelerated deterioration through the comparison of the natural vibration and on site vibration. The natural frequencies of the strut tube glass insulator was measured within a range of less than 1kHz. In the on site vibration, the largest frequency that was imposed on strut tube glass insulators was 80Hz with 1.13g of vertical vibration in the viaduct section, the largest vertical vibration (0.38g) was detected at 103Hz in the open route section. When site vibration and natural vibration of strut tube glass insulators were compared in terms of characteristics, the resonance frequency was not the same. In both the viaduct and open route sections, it seems that the impact by vertical vibration in strut tube glass insulators is large. It's very unlikely that glass insulators were damaged by fatigue accumulation of vibration since the possibility of damage by resonance was very low in consideration of the characteristics of natural vibration and site vibration of glass insulators. In addition, no damage was detected in the accelerated deterioration test.