• Title/Summary/Keyword: vertical wall

Search Result 1,037, Processing Time 0.026 seconds

Numerical Study on Propylene Vertical Wall Fires (프로필렌 수직벽 화재의 수치적 연구)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.133-137
    • /
    • 2009
  • The Fire Dynamics Simulator (FDS), a computational fluid dynamics model for fire simulation, was applied to propylene vertical wall fires, to confirm its accuracy in simulation of vertical wall fires. The temperature profiles at the center of the burner obtained for mass loss rates per unit area in the range of $7.0{\sim}29.29g/m^2-s$ were compared with those of experiment. Comparisons of the heat flux distributions along the vertical centerline on the wall surface were made with the measurements. It was shown that the computed temperature profiles were in good agreement with the experiment. It was also noted that the peak temperature near the wall was underpredicted, the heat flux was too high compared with the measurements, and hence improvements are required for FDS in simulation of the vertical wall fires.

Influence of the stiffness of Vertical Joints on the Behaviour of Precast Shear Walls. Part1. Load Case 1 (연직접합(鉛直接合)의 강성(剛性)이 프리케스트 전단벽(剪斷壁)의 구조적거동(構造的擧動)에 미치는 영향(影響) I. 하중조합(荷重組合) 1에 대하여)

  • Park, Kyung-Ho
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.103-116
    • /
    • 1983
  • Recent developments in multi-storey buildings for residential purpose have led to the extensive use of shear walls for the basic structural system. When the coupled shear wall system is used, joined together with cast-in-place concrete or mortar (or grout), the function of the continuous joints is a crucial factor in determining the safety of L.P. Precast concrete shear wall structures, because the function of the continuous joints(Vertical wall to wall joints) is to transfer froces from one element(shear wall panel) to another, and if sufficient strength and ductility is not developed in the continuous joints, the available strength in the adjoining elements may not be fully utilized. In this paper, the influence of the stiffness of vertical joints(wet vertical keyed shear joints) on the behaviour of precast shear walls is theoretically investigated. To define how the stiffness of the vertical joints affect the load carrying capacity of L.P.Precast concrete shear wall structure, the L.P.Precast concrete shear wall structure is analyzed, with the stiffness of the vertical joints varying from $K=0.07kg/mm^3$(50MN/m/m) to $K=1.43kg/mm^3$(1000MN/m/m), by using the continuous connection method. The results of the analysis shows that at the low values of the vertical stiffness, i.e. from $K=0.07kg/mm^3$(50MN/m/m) to $K=0.57kg/mm^3$(400MN/m/m), the resisting bending moment and shearing force of precast shear walls, the resisting shearing force of vertical joints and connecting beams are significantly affected. The detailed results of analysis are represented in the following figures and Tables.

  • PDF

A Study on the Vertical Garden Design for Indoor Space - Focused on Green Wall in Lobby Space - (실내 벽면녹화의 공간 계획 경향에 관한 연구 - 로비공간의 적용 사례를 중심으로 -)

  • Yang, Sae-Yi;Cho, Sung-Ik
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.3
    • /
    • pp.33-42
    • /
    • 2013
  • The purpose of this study was to analyze the design trend of the vertical garden design in the indoor space through the examples of green wall in the lobby space. For the analysis, this study looks into the 'Guide for the Building Greening System' to understand the technical consideration for the green wall. After that, the key design elements was drawn from existing green walls through the literature review and field survey and field-survey. The study picked six green walls which was completed after 2000 in the lobby space in Seoul. The major findings of this study were as follows: First, the design factors mainly depend on the plant selection, which leads to the outlook and texture of the vertical walls. The texture is expressed by the two-dimensional or three-dimensional planting methods which is related to the selection of plant species. Second, the vertical walls in the lobby area should be planned for the function of space which could be transition, human traffic, mood and attraction. Third, the vertical wall should be integrated with the surroundings in order to reinforces the dynamic or static space experience.

Vertical Earth Pressure Distribution on Cantilever Retaining Wall (역 T 형 옹벽에 작용하는 연직토압분포)

  • Yoo, Nam-Jae;Lee, Myeung-Woog
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.181-189
    • /
    • 1996
  • Centrifuge model tests of cantilever retaining wall were performed to investigate the vertical stress distribution due to selfweight of backfill material. Model tests were carried out to find the effect of arching action on vertical stress distribution by changing the roughness of rigid boundary slope and the distance between retaining wall and boudary slope. A reduced scale model of cantilever retaining wall was made with concrete and Jumunjin Standary Sand with 80 % of relative density was used as foundation and backfill material. Centrifuge tests were performed by increasing g-level up to 40 g with measuring vertical stress induced by selfweight of backfill material. Test results on vertical stress distribution were analyzed and compared with results of Silo theory.

  • PDF

An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces (전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구)

  • Chun, Ho-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

Settlement Reduction Effect of Advanced Back-to-Back Reinforced Retaining Wall

  • Koh, Taehoon;Hwang, Seonkeun;Jung, Hunchul;Jung, Hyuksang
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.107-111
    • /
    • 2013
  • In order to constrain the railway roadbed settlement which causes track irregularity, and thus threats running stability and ride quality, advanced Back-to-Back (BTB) reinforced retaining wall was numerically analyzed as railway roadbed structure. This study is intended to improve conventional Back-to-Back reinforced retaining wall as the technology which would reduce the roadbed settlement in a way of constraining the lateral displacement of its prestressed vertical facing and inducing arching effects in roadbed (backfill) placed between masonry diaphragm wall and vertical facing. As a result of numerical analysis, it was found that the roadbed settlement was reduced by 10% due to the prestressed vertical facing and embedded masonry diaphragm wall of the advanced Back-to-Back reinforced retaining wall system.

Ground Deformation Evaluation during Vertical Shaft Construction through Digital Image Analysis

  • Woo, Sang-Kyun;Woo, Sang Inn;Kim, Joonyoung;Chu, Inyeop
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.285-293
    • /
    • 2021
  • The construction of underground structures such as power supply lines, communication lines, utility tunnels has significantly increased worldwide for improving urban aesthetics ensuring citizen safety, and efficient use of underground space. Those underground structures are usually constructed along with vertical cylindrical shafts to facilitate their construction and maintenance. When constructing a vertical shaft through the open-cut method, the walls are mostly designed to be flexible, allowing a certain level of displacement. The earth pressure applied to the flexible walls acts as an external force and its accurate estimation is essential for reasonable and economical structure design. The earth pressure applied to the flexible wall is closely interrelated to the displacement of the surrounding ground. This study simulated stepwise excavation for constructing a cylindrical vertical shaft through a centrifugal model experiment. One quadrant of the axisymmetric vertical shaft and the ground were modeled, and ground excavation was simulated by shrinking the vertical shaft. The deformation occurring on the entire ground during the excavation was continuously evaluated through digital image analysis. The digital image analysis evaluated complex ground deformation which varied with wall displacement, distance from the wall, and ground depth. When the ground deformation data accumulate through the method used in this study, they can be used for developing shaft wall models in future for analyzing the earth pressure acting on them.

Modification of Bouwer and Rice method using flow net to evaluate hydraulic conductivity of vertical cutoff wall considering filter cake development (연직차수벽에서 필터케익을 고려한 순간 변위시험 해석시 유선망을 이용한 수정 Bouwer and Rice법의 적용)

  • Nguyen, The Bao;Kwak, Tae-Hoon;An, Yong-Hoon;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1478-1486
    • /
    • 2009
  • As a conventional line-fitting method, the Bouwer and Rice method has been popularly adopted to estimate the hydraulic conductivity of an aquifer through a slug test. Because a ventical cutoff wall is usually very compressible and features a small wall thickness, the Bouwer and Rice method should be carefully used for the vertical cutoff wall. In addition, a relatively impermeable layer, called a filter cake, formed at the interface between the cutoff wall and the natural soil formation makes it difficult to use the Bouwer and Rice method directly. In order to overcome such limitations, the original Bouwer and Rice method is modified by incorporating the concept of the flow net method. In this modification, the geometry condition of cutoff walls including the filter cake is effectively considered in evaluating the hydraulic conductivity of a vertical cutoff wall.

  • PDF

Characteristics of Vertical Vibration Transfer in Vertical Way according to Shear Wall Apartment Structures due to Heel-drop Impact (발 뒤꿈치 충격에 의한 전단벽식 공동주택 수직진동의 수직방향 진동전달 특성)

  • Chun, Ho-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.70-73
    • /
    • 2006
  • Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to heel-drop impact forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on two shear wall building structures. The results of this study suggest that the characteristics of vertical vibration transfer are similar in terms of the directions of transfer.

  • PDF

Development and Seismic Performance of Vertical Joints in Precast Concrete Shear Walls under Cyclic Loads (반복하중을 받는 PC 전단벽체에서 수직접합부의 개발 및 내진성능평가)

  • Kim, Ook Jong;Oh, Jae Keun;Kang, Su Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.140-148
    • /
    • 2012
  • Recently there are many attempts to introduce PC construction method in buildings. But the study on PC structural wall has been made progress so slowly because it is very difficult to develop new items. In this study, we have developed new vertical joint on PC wall in order to upgrade constructivity and structural performance of the existing connections, then we have evaluated the seismic resistance performance. As a result of the cyclic loading tests for two specimens, proposed vertical joint on PC wall has shown that it behave the excellent structural performance in comparison to PC wall having no joint. Therefore, we think that proposed vertical joint is the system to apply buliding structure.