• Title/Summary/Keyword: vertical temperature

Search Result 1,574, Processing Time 0.03 seconds

A study on the Development of Vertical Air Temperature Distribution Model in Atrium (아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구)

  • Kim, Y.I.;Cho, K.H.;Kim, K.W.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

An Optimal Design of a Vertical Guide Bearing for Vibration Reduction (축계 진동 저감을 위한 수직형 안내 베어링의 최적 설계)

  • Ha, Hyun-Cheon;Park, Chul-Hyun;Kim, Hyung-Ja
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.64-72
    • /
    • 2001
  • This paper describes an optimal design technology in a segment type vertical guide bearing for vertical rotating machinery. Segment type vertical guide bearings have widely used for vertical rotating machinery, however bearing problems, such as excessive vibration and temperature rise, frequently take place in the actual machine. Such excessive vibration magnitude and/or abnormal bearing metal temperature rise result in serious damage and economic losses. Thus the segment type vertical guide bearing should be designed to get optimal characteristics in order to maintain stable operation without bearing failure due to abnormal vibration and/or abnormal bearing metal temperature. The preload ratio is the most important parameter in designing the segment type vertical guide bearing. Because adjustment of the bearing preload by changing the bearing clearance could easily control both the bearing stiffness and the cooling effect. In the paper, the influence of the preload effects on the bearing metal temperature and the bearing stiffness has been investigated both theoretically and experimentally in order to find out an optimum preload ratio. Results show that the segment type vertical guide bearing has an optimum preload ratio at which the bearing stiffness reaches a masimum value while the bearing metal temperature is minimized.

  • PDF

Simulation for the effect of vertical groundwater flux on the subsurface temperature distribution

  • Shin Ji-Youn;Lee Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.383-386
    • /
    • 2006
  • Subsurface temperature is affected by heat advection due to groundwater advection. Temperature-depth profile can be perturbed especially when there are significant vertical groundwater flux caused by external force such as injection or extraction. This research is to clarify the change of subsurface temperature distribution when the 40m x l0m sandy aquifer is stimulated by two different vertical flux($case1:\;{\pm}10^{-5}m^3/s,\;case2:\;{\pm}4{\times}10^{-5}m^3/s$) using a program called HydroGeoSphere. The resulting temperature distribution contour map shows pumping causes vertical attraction of water from deeper and warmer place which result in rising up isotherm. Additionally more injection/extraction rate, more vertical groundwater flux leads to faster Increase in temperature near the pumping well.

  • PDF

Application of the Through-Transmitted Ultrasonic Signal for the Identification of Two-Phase Flow Patterns in a Simulated High Temperature Vertical Channel

  • Chu In-Cheol;Song Chul-Hwa;Baek Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.12-23
    • /
    • 2004
  • In the present study a new measurement technique has been developed, which uses an ultrasonic transmission signal in order to identify the vertical two phase flow pattern. The ultrasonic measurement system developed in the present study not only provides the information required for the identification of vertical two phase flow patterns but also makes real time identification possible. Various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. have been accurately identified with the present ultrasonic measurement system under atmospheric condition. In addition, the present test apparatus can practically simulate the ultrasonic propagation characteristics under high temperature and high pressure systems. Therefore, it is expected that the present ultrasonic flow pattern identification technique could be applicable to the vertical two phase flow systems under high temperature and high pressure conditions.

Year-to-year Variability of the Vertical Temperature Structure in the Youngsan Estuary

  • Cho, Yang-Ki;Lee, Kyeong-Sig;Park, Kyung-Yang
    • Ocean and Polar Research
    • /
    • v.31 no.3
    • /
    • pp.239-246
    • /
    • 2009
  • Long-term observations were conducted between 1997 and 2002 to examine the variability of the vertical temperature structure in the Youngsan Estuary, southwest Korea, in summer. The observed hydrographic data revealed that the temperature minimum layer in the middle depth persisted through the entire summer of 2000 but was rarely observed in other years. The variability in the vertical structure might be affected by the air temperature during the previous winter and the density difference between the open sea and the estuary. In 2000, the air temperature in the previous winter was lowest and the horizontal density difference during summer was largest. The large horizontal density difference probably produced more active driving of warm water along the bottom, which would have intruded into the Youngsan Estuary. Furthermore, the cold previous winter would have provided a better condition for maintaining cold temperatures in the middle water layer for a longer period.

Spatial Distribution Characteristics of Vertical Temperature Profile in the South Sea of Jeju, Korea (제주 남부해역 수온 수직구조의 공간분포 특성 파악)

  • Yoon, Dong-Young;Choi, Hyun-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.162-174
    • /
    • 2012
  • To visualize the characteristics of vertical seawater temperature data, in the ocean having 3D spatial characteristics, 2D thematic maps like horizontal seawater temperature distribution map at each depth layer and 3D volume model using 3D spatial interpolation are used. Although these methods are useful to understand oceanographic phenomena visually, there is a limit to analyze the spatial pattern of vertical temperature distribution or the relationship between vertical temperature characteristics and other oceanic factors (seawater chemistry, marine organism, climate change, etc). Therefore, this study aims to determine the spatial distribution characteristics of vertical temperature profiles in the South Sea of Jeju by quantifying the characteristics of vertical temperature profiles by using an algorithm that can extract the thermocline parameters, such as mixed layer depth, maximum temperature gradient and thermocline thickness. For this purpose spatial autocorrelation index (Moran's I) was calculated including mapping of spatial distribution for three parameters representing the vertical temperature profiles. Also, after grouping study area as four regions by using cluster analysis with three parameters, the characteristics of vertical temperature profiles were defined for each region.

Temperature Properties of Vertical Reinforcements in Wall Structures in Relation to the Different Methods of Bubble Sheet Installation in Winter (겨울철 버블시트 포설방법 변화에 따른 벽식구조 수직철근의 온도 특성)

  • Kim, Tae-Woo;Lee, Jea-Hyeon;Kyung, Yeong-Hyeok;Lee, Jong-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.11-12
    • /
    • 2017
  • This study aims to analyze the properties of the temperature change in vertical reinforcements in outdoor wall structures in winter in relation to the different methods of bubble sheet installation, and to subsequently determine the possibility of initial frost damage to the concrete as a result of low temperature. As for the experimental variables, double bubble sheets were used as curing materials, and the curing method was to model the part where the slab and the wall intersect and the rebar is exposed, and to measure the change of temperature around the exposed rebar in accordance with the change of the coating curing. It was found that by employing curing method B, which is to install the bubble sheet between the vertical reinforcements, the most vulnerable area, which is 50mm below(④) the surface of the concrete, would be lowered to sub-zero temperature 20 hours later than when using curing method A, and that therefore it is more effective to install the bubble sheet between the vertical reinforcements for the prevention of initial frost damage.

  • PDF

Utilization of Energy in the Sea Water of the Southeastern Yellow Sea (한국남서해의 열 에너지 이용)

  • 장선덕
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.113-116
    • /
    • 1978
  • To ascertain the feasibility of the energy utilization in the sea adjacent to Korea, the distribution of the vertical temperature difference and the seasonal variation in the southeastern Yellow Sea are studied in relation to the sea water circulation. In summer, a region of high vertical temperature difference of approximately 16$^{\circ}C$ was found at a distance of approximately 40 miles from the western coast of Korea. It is located at the west of 125${\circ}$ 30`E and at the north of 34${\circ}$N. The vertical temperature structure is sustained by the inflow of Yellow Sea Warm Current water, the warming of the surface water of the Yellow Sea and the periodical renewal of the Yellow Sea Cold Water. It may be stated that power can be obtained from the sea water by making the use of the temperature difference. The vertical temperature difference was around 14$^{\circ}C$ in the western and southern waters of Jejudo Island. The vertical temperature difference decreases in autumn, and disappears due chiefly to the vigorous convective vertical mixing in winter when the northwest monsoon prevails. The power can be obtained from sea throughout the year, if power generation by the temperature difference is combined with that by wind and wave, and systemized in such a way that the former is employed in the hot season of summer, while the latter in winter and spring.

  • PDF

Vertical Distribution of Temperature and Tropopause Height Changes in Future Projections using HadGEM2-AO Climate Model (HadGEM2-AO를 이용한 연직기온 분포와 대류권계면 높이 변화 미래전망)

  • Lee, Jaeho;Baek, Hee-Jeong;Cho, Chunho
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • We present here the future changes in vertical distribution of temperature and tropopause height using the HadGEM2-AO climate model forced with Representative Concentration Pathways (RCPs) scenarios. Projected changes during the 21st century are shown as differences from the baseline period (1971~2000) for global vertical distribution of temperature and tropopause height. All RCP scenarios show warming throughout the troposphere and cooling in the stratosphere with amplified warming over the lower troposphere in the Northern Hemisphere high latitudes. Upper troposphere warming reaches a maximum in the tropics at the 300 hPa level associated with lapse-rate feedback. Also, the cooling in the stratosphere and the warming in the troposphere raises the height of the tropopause.

Experimental Study of Natural Convection Due to Combined Buoyancy in a Rectangular Enclosure (직각 밀폐용기내의 복합부력에 의한 자연대류에 관한 실험적 연구)

  • 이진호;현명택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.247-256
    • /
    • 1986
  • An experimental investigation was conducted to study natural convection due to temperature and concentration differences between the two opposite end walls of a rectangular enclosure of aspect ratio 0.2. Flow motion in the enclosure appears as a uni-cell flow pattern for the relatively lower concentration and higher temperature differences and vice versa, while it appears as a multicell flow pattern for the comparable temperature and concentration differences. In the multi-cell flow regime, when the cellular flow motiion is very slow, vertical temperature differences within the cells are negligible while the vertical concentration differences are large. In addition, both the temperature and concentration differences are negligible across the interface between the slowly moving cells. For the fast moving cellular flow motion, on thel contrary, vertical temperature differences within the cells are large while the vertical concentration differences are negligible. In this case, temperature differences are negligible and the concentration differences are large across the interface between the fase moving cells.