• 제목/요약/키워드: vertical structure

검색결과 2,442건 처리시간 0.028초

Effects of High Damping Rubber Bearing on Horizontal and Vertical Seismic Responses of a Pressurized Water Reactor

  • Bong Yoo;Lee, Jae-Han;Koo, Gyeong-Hoi
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.1021-1026
    • /
    • 1995
  • The seismic responses of a base isolated Pressurized Water Reactor (PWR) are investigated using a mathematical model which expresses the superstructure as lumped mass-spring model and the seismic isolator as an equivalent spring-damper. Time history analyses are performed for the 1940 E1 Centre earthquakes in both horizontal and vertical directions. In the analysis, structural damping of 5% is used for the superstructure. The isolator damping ratios of 12% for horizontal and 5% for vertical directions are used. The acceleration responses in base isolated PWR superstructure with high damping rubber bearings are much smaller than those in fixed base structure in horizontal direction. However, the vertical acceleration responses at the superstructure in the base isolation system are amplified to some extent. It is suggested that the vertical seismic responses at the superstructure should be reduced by introducing a soft vertical isolation device.

  • PDF

초고층 건물의 기둥축소와 지진하중에 대한 구조적 영향 (A Column Shortening on High-Rise Building and Structural Effect under seismic load)

  • 정은호;김희철
    • 한국지진공학회논문집
    • /
    • 제1권3호
    • /
    • pp.59-68
    • /
    • 1997
  • 대도시에서 초고층 건물의 필요성은 구조 기술자에게 새로운 문제를 안겨주었다. 기둥축소의 효과는 설계 및 시공에 있어 특별한 주의를 요구한다. 기둥의 축소는 칸막이, 마감, 그리고 설비체계와 같이 수직하중을 지탱하도록 고려되어 있지 않은 비구조적인 요소에 영향을 미친다. 또한 각 기둥의 축소량 차이는 주위의 슬래브 및 보와 같은 부재들을 경사지게 한다. 축소량을 예측하는 목적은 부등 축소량의 차이를 미리 보정하는데 있다. 본 연구는 부동 축소량에 의한 주구조부재의 영향에 대한 내용을 다루었다. 자중으로 인해 초지 수직변위를 갖는 52층 철근콘크리트 구조물에 지진하중을 적용하여 구조물에 미치는 영향을 평가하였다. 각 수직구조요소에 대한 축소량은 전산화된 기둥축소 해석 프로그램을 이용하여 예측되었으며 지진하중으로 인한 축소량이 보정된 구조물과 보정되지 않은 구조물 사이의 응력을 조사하였다.

  • PDF

중간수심역 조건에서 직립식 구조물의 전달파고계수 산정에 관한 수리실험 (Hydraulic Experiments on Transmission Coefficients for Vertical Structure under Intermediate Water Depth Condition)

  • 김영택;이종인
    • 한국해안·해양공학회논문집
    • /
    • 제27권5호
    • /
    • pp.345-352
    • /
    • 2015
  • 본 연구에서는 직립식 구조물의 전달파고계수 산정을 위한 2차원 수리실험을 실시하였다. 불규칙파를 입사파로 적용하였으며 직립식 구조물에 대한 전달파고계수 산정식을 제안하고, Goda(1969) 등의 결과와 비교하였다. Goda(1969)의 결과는 입사파로 규칙파를 적용한 결과로서 불규칙파를 적용한 본 실험의 결과와 차이를 보였다. Goda의 결과가 본 연구에 비하여 크게 전달파고계수를 제시하는 것을 알 수 있었다. 또한 Goda는 직립벽에 대하여 평균, 상한 및 하한에 대한 계수값을 제시하였으나(d=h조건), 본 연구에서는 각각의 설계요소(구조물 폭, 수심, 파장 등)가 전달파고계수에 주는 영향을 계수를 통하여 정량적으로 제시하였다. 또한 여유고가 0인 조건에 대한 에너지보존 및 전달파고 특성을 제시하였다.

Effects of inclined bedrock on dissimilar pile composite foundation under vertical loading

  • Kaiyu, Jiang;Weiming, Gong;Jiang, Xu;Guoliang, Dai;Xia, Guo
    • Geomechanics and Engineering
    • /
    • 제31권5호
    • /
    • pp.477-488
    • /
    • 2022
  • Pile composite foundation (PCF) has been commonly applied in practice. Existing research has focused primarily on semi-infinite media having equal pile lengths with little attention given to the effects of inclined bedrock and dissimilar pile lengths. This investigation considers the effects of inclined bedrock on vertical loaded PCF with dissimilar pile lengths. The pile-soil system is decomposed into fictitious piles and extended soil. The Fredholm integral equation about the axial force along fictitious piles is then established based on the compatibility of axial strain between fictitious piles and extended soil. Then, an iterative procedure is induced to calculate the PCF characteristics with a rigid cap. The results agree well with two field load tests of a single pile and numerical simulation case. The settlement and load transfer behaviors of dissimilar 3-pile PCFs and the effects of inclined bedrock are analyzed, which shows that the embedded depth of the inclined bedrock significantly affects the pile-soil load sharing ratios, non-dimensional vertical stiffness N0/wdEs, and differential settlement for different length-diameter ratios of the pile l/d and pile-soil stiffness ratio k conditions. The differential settlement and pile-soil load sharing ratios are also influenced by the inclined angle of the bedrock for different k and l/d. The developed model helps better understand the PCF characteristics over inclined bedrock under vertical loading.

수평.상하 지진을 받는 아치구조물에 대한 등가정적지진력 제안 (A Proposal of Quasi Static Seismic Force for Arches subjected to both the Horizontal and Vertical Seismic Wave)

  • 정찬우
    • 한국공간구조학회논문집
    • /
    • 제7권6호
    • /
    • pp.103-110
    • /
    • 2007
  • 일반적인 각형 라멘 구조물에 있어서, 상하지진동은 수평지진동에 비하여 구조물에 미치는 영향이 작다고 간주되어, 내진설계에 있어서는 수평지진동만을 고려하는 것이 일반적이다. 그러나, 공간구조물에서는 수평지진동에 의해 수평방향뿐만 아니라 연직방향으로도 구조물의 동적응답이 크게 증폭되며, 또한 상하지진동에 의해서도 연직방향뿐만 아니라 수평방향으로도 구조물의 동적응답이 크게 증폭되는 특성을 가지고 있으므로, 수평 상하 양방향의 지진동을 모두 고려할 필요가 있다. 본 논문에서는 공간구조물의 가장 간단한 구조형식인 아치를 대상으로, 수평 상하지진동의 동시입력에 대한 순간가속도 응답배율의 특성을 고찰하였다. 또한, 지진동의 단독입력시의 등가정적지진력을 이용하여, 지진동의 동시입력에 대한 등가정적지진력을 제안하였다.

  • PDF

Design and analysis of isolation effectiveness for three-dimensional base-seismic isolation of nuclear island building

  • Zhu, Xiuyun;Lin, Gao;Pan, Rong;Li, Jianbo
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.374-385
    • /
    • 2022
  • In order to investigate the application of 3D base-seismic isolation system in nuclear power plants (NPPs), comprehensive analysis of constitution and design theory for 3-dimensional combined isolation bearing (3D-CIB) was presented and derived. Four different vertical stiffness of 3D-CIB was designed to isolate the nuclear island (NI) building. This paper aimed at investigating the isolation effectiveness of 3D-CIB through modal analysis and dynamic time-history analysis. Numerical results in terms of dynamic response of 3D-CIB, relative displacement response, acceleration and floor response spectra (FRS) of the superstructure were compared to validate the reliability of 3D-CIB in mitigating seismic response. The results showed that 3D-CIB can significantly attenuate the horizontal acceleration response, and a fair amount of the vertical acceleration response reduction of the upper structure was still observed. 3D-CIB plays a significant role in reducing the horizontal and vertical FRS, the vertical FRS basically do not vary with the floor height. The smaller the vertical stiffness of 3D-CIB is, the better the vertical isolation effectiveness is, whereas, it will increase the displacement and the rocking effect of superstructure. Although the advantage of 3D-CIB is that the vertical stiffness can be flexibly adjusted, it should be designed by properly accounting for the balance between the isolation effectiveness and displacement control including rocking effect. The results of this study can provide the technical basis and guidance for the application of 3D-CIB to engineering structure.

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro;Kawasaki, Yoshizo;Tagawa, Kengo
    • Structural Engineering and Mechanics
    • /
    • 제11권6호
    • /
    • pp.605-616
    • /
    • 2001
  • The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.

지중 RC 도시지하철고 구조물의 내진설계 (A Seismic Design of RC Underground Subway Structure)

  • 정제평;임동원;이성로;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.357-362
    • /
    • 2000
  • This Paper presents dynamic analysis of underground R/C Subway Structure, subjected to seismic actions. Earthquakes brought serious damage to RC subway Structure. Foe studying the collapse mechanism of underground RC Subway, seismic of a subway station is simulated in using FEM program ASP2000 of two-dimension based on the path dependent RC elastic model, soil foundation and interfacial models. The shear failure of intermediate vertical columns is founds to be the major cause of the structural collapse. According to FEM simulation of the failure mechanism, it is considered that the RC column would lose axial load carrying capacity after the occurrence of the localized diagonal shear cracks , and sudden failure of the outer frame would be followed. Specially, the shear stress in the middle slab reaches maximum shear capacity. So, the Structure would fail in the middle slab as a result of erasing the vertical ground motion computation.

  • PDF

정보통신산업에서 망과 서비스의 결합여부가 서비스 품질에 미치는 영향 분석 (Analysis of the Effect of Integrating Network Operating and Service Providing on Service Quality in Telecommunication Industry)

  • 김태유;이용길;김연배
    • 기술경영경제학회:학술대회논문집
    • /
    • 기술경영경제학회 1999년도 제15회 하계 학술발표회 논문집
    • /
    • pp.203-225
    • /
    • 1999
  • In this paper, I tried to analyze the relationship between the market structure of teleommunicatin industry and market performance using Economides and Lehr's results considering composite goods methods. And I took three policy scenarios into account. First, government tires to implement the policy which divides the integrated monopoly into network operator and service provider, then invite competition to service part. Second, government tries to implement the policy which invite the competition to service part only. Third, government tries to implement the policy which invite the competition to integrated duopoly. I gained the best result in the third scenario. So we can conclude that Parallel vertical integration is the best market structure. I also specially checked the relationship between the market structure and service quality. I gained the best service quality in the third scenario. So we can conclude that Parallel Vertical Integration is also the best market structure with regard to the service quality.

  • PDF

수신함수를 이용한 관측소 하부의 지진파 속도구조 (Crustal structure beneath broadband seismic station using receiver function)

  • 박윤경;전정수;김성균
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.45-49
    • /
    • 2003
  • The velocity structure beneath the CHNB broadband station is determined by receiver function analysis using by from teleseismic P waveforms. The detailed broadband receiver functions are obtained by stacking method for source-equalized vertical, radial and tangential components of teleseismic P waveforms. A time domain inversion uses the stacked radial receiver function to determine vertical P wave velocity structure beneath the station. The crustal velocity structures beneath the stations are estimated using the receiver function inversion method in the case at the crustal model parameterized by many thin, flat-tying, homogeneous layers. The result of crust at model inversion shows the crustal velocity structure beneath the CHNB station varies smoothly with increasing depth, and there are six discontinuity around 2.5km, 6.25km, 12.5km, 22.5km and 27.5km depth, with Moho discontinuity at about 32.5km depth.

  • PDF