• 제목/요약/키워드: vertical stiffness

검색결과 655건 처리시간 0.034초

지중매설 연성관의 관강성 추정 (Pipe Stiffness Prediction of Buried Flexible Pipes)

  • 박준석;김선희;김응호
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.13-20
    • /
    • 2012
  • In this paper, we present the result of an investigation pertaining to the pipe stiffness of buried flexible pipes. Pipe stiffness (PS) formula for the parallel plate loading condition is derived based on the elasticity theory. Vertical and horizontal displacements are also derived. Vertical deflection is always larger than the horizontal deflection because some of energy due to overburden load is stored in the pipe but the difference is negligibly small. In the study, mechanical properties of the flexible pipes produced in the domestic manufacturer are tested and the results are reported in this paper. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is less than 14% although there are significant variations in the mechanical properties of the pipe material. Therefore, it was found that the finite element analysis can be used to predict the pipe stiffness instead of conducting parallel plate loading test.

강성제어 구조물을 이용한 수평구동형 박막 PZT 엑츄에이터의 설계, 제작 및 특성평가 (Design, Fabrication and Characterization of Lateral PZT actuator using Stiffness Control)

  • 서영호;최두선;이준형;이택민;제태진;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.756-759
    • /
    • 2004
  • We present a piezoelectric actuator using stiffness control and stroke amplification mechanism in order to make large lateral displacement. In this work, we suggest stiffness control approach that generates lateral displacement by increasing the vertical stiffness and reducing the lateral stiffness using additional structure. In addition, an additional structure of a serpentine spring amplifies the lateral displacement like leverage structure. The suggested lateral PZT actuator (bellows actuator) consists of serpentine spring and PZT/electrode layer which is located at the edge of the serpentine spring. The edge of the serpentine spring prevents the vertical motion of PZT layer, while the other edge of the serpentine spring makes stroke amplification like leverage structure. We have determined dimensions of the bellows actuator using ANSYS simulation. Length, width and thickness of PZT layer are 135$\mu$m, 20$\mu$m and 0.4$\mu$m, respectively. Dimensions of the silicon serpentine spring are thickness of 25$\mu$m, length of 300$\mu$m, and width of 5$\mu$m. The bellows actuator has been fabricated by SOI wafer with 25$\mu$m-top silicon and 1$\mu$m-buried oxide layer. The bellows actuator shows the maximum 3.93$\pm$0.2$\mu$m lateral displacement at 16V with 1Hz sinusoidal voltage input. In the frequency response test, the fabricated bellows actuator showed consistent displacement from 1Hz to 1kHz at 10V. From experimental study, we found the bellows actuator using thin film PZT and silicon serpentine spring generated mainly laterally displacement not vertical displacement at 16V, and serpentine spring played role of stroke amplification.

  • PDF

Relationship between Dimensionless Leg Stiffness and Kinetic Variables during Gait Performance, and its Modulation with Body Weight

  • Hyun, Seung Hyun;Ryew, Che Cheong
    • 한국운동역학회지
    • /
    • 제26권3호
    • /
    • pp.249-255
    • /
    • 2016
  • Objective: This purpose of this study was to analyze the relationship between dimensionless leg stiffness and kinetic variables during gait performance, and its modulation with body weight. Method: The study sample consisted of 10 young women divided into 2 groups (Control, n=5 and Obese, n=5). Four camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) and one force plate (AMTI., USA) were used to analyze the vertical ground reaction force (GRF) variables, center of pressure (COP), low limb joint angle, position of pelvis center and leg lengths during the stance phase of the gait cycle. Results: Our results revealed that the center of mass (COM) displacement velocity along the y-axis was significantly higher in the obese group than that in control subjects. Displacement in the position of the center of the pelvis center (Z-axis) was also significantly higher in the obese group than that in control subjects. In addition, the peak vertical force (PVF) and dimensionless leg stiffness were also significantly higher in the obese group. However, when normalized to the body weight, the PVF did not show a significant between-group difference. When normalized to the leg length, the PVF and stiffness were both lower in the obese group than in control subjects. Conclusion: In the context of performance, we concluded that increased dimensionless leg stiffness during the gait cycle is associated with increased velocity of COM, PVF, and the change in leg lengths (%).

수직증축시 기존말뚝과 보강말뚝의 하중분담율 및 축강성 분석 (A Study on the Load Distribution Ratio and Axial Stiffness on Existing and Reinforcing-Pile in Vertical Extension Remodeling)

  • 정상섬;조현철
    • 한국지반공학회논문집
    • /
    • 제35권1호
    • /
    • pp.17-30
    • /
    • 2019
  • 본 연구는 3차원 수치해석을 통해 기존말뚝과 보강말뚝의 하중분담율(Load Distribution Ratio)과 근사적 해석 기법으로 보강말뚝의 축방향 강성(Axial Stiffness)을 산정하였다. 시공단계를 고려하여 말뚝기초의 LDR에 영향을 미치는 인자를 파악하기 위해서 1) 말뚝기초의 강성, 2) 말뚝기초의 선단지지조건, 3) 기초판 접촉효과, 4) 보강말뚝의 설치위치에 따라 해석을 수행하여 기존말뚝과 신설말뚝의 하중분담율 거동을 확인하였다. 또한 5) 기존말뚝의 축방향 강성($K_{ve}$)를 사용하여 말뚝지지 전면기초의 3차원 근사적 해석기법(YSPR)으로 보강말뚝의 직경에 따른 강성($K_{vr}$)을 산정하고, 장기간 사용으로 인한 경화를 고려하여 $K_{ve}$를 3단계로 나누어 감소시켜 보강말뚝의 강성 변화의 경향을 살펴보고, 신설 말뚝의 강성 산정방법을 제시하였다.

해저지진의 수직지반운동에 의한 부유식 해양구조물의 지진응답 해석기법 개발 (Analysis of Earthquake Responses of a Floating Offshore Structure Subjected to a Vertical Ground Motion)

  • 이진호;김재관;진병무
    • 한국지진공학회논문집
    • /
    • 제18권6호
    • /
    • pp.279-289
    • /
    • 2014
  • Considering a rigorously fluid-structure interaction, a method for an earthquake response analysis of a floating offshore structure subjected to vertical ground motion from a seaquake is developed. Mass, damping, stiffness, and hydrostatic stiffness matrices of the floating offshore structure are obtained from a finite-element model. The sea water is assumed to be a compressible, nonviscous, ideal fluid. Hydrodynamic pressure, which is applied to the structure, from the sea water is assessed using its finite elements and transmitting boundary. Considering the fluid-structure interaction, added mass and force from the hydrodynamic pressure is obtained, which will be combined with the numerical model for the structure. Hydrodynamic pressure in a free field subjected to vertical ground motion and due to harmonic vibration of a floating massless rigid circular plate are calculated and compared with analytical solutions for verification. Using the developed method, the earthquake responses of a floating offshore structure subjected to a vertical ground motion from the seaquake is obtained. It is concluded that the earthquake responses of a floating offshore structure to vertical ground motion is severely influenced by the compressibility of sea water.

수직펌프의 진동해석 (Vibration Analysis of Vertical Pumps)

  • 홍진선
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.928-935
    • /
    • 1999
  • Vertical pumps are widely used owing to the fact that they occupy small floor space. In this type of pumps, however, the vibrational problems are very important, since, in many cases, they have less stiffness in comparison with lateral pumps. This study presents a simple solution method for calculating the natural frequencies and modes of vertical pumps. In this study, a mode of a vertical pump was developed and the nondimensional parameters for the vibrational characteristics of it were determined. Added mass was calculated for the effects of water and the transfer matrix method was used.

  • PDF

교체 가능한 강재 헌치 시스템으로 보강한 철근 콘크리트 보-기둥 구조물의 내진성능에 관한 실험적 연구 (An Experimental Study on Seismic Performance of Reinforced Concrete Beam-Column Retrofitted with Replaceable Steel Haunch System)

  • 김윤성;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제24권1호
    • /
    • pp.81-88
    • /
    • 2024
  • The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.

체결장치의 강성 평가를 위한 실험적 연구 - 레일 연직방향 병진강성, 레일 강축에 대한 회전강성 - (An Experimental Study to Evaluate the Stiffness of Fastening Systems - Translational Stiffness along the Vertical Axis of Rail, Rotational Stiffness along the Strong Axis of Rail -)

  • 김정훈;한상윤;임남형;강영종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.71-78
    • /
    • 2008
  • 철도교량의 경우, 열차하중에 의한 영향으로 교량 단부에서 상향력이 발생하였으며, 이 상향력은 체결장치에 압축력과 인장력을 유발시켰다. 현재까지 이에 대한 안전성을 검토하기 위해 체결장치를 1방향의 스프링 요소로 모사하여 구조해석을 수행해 왔다. 이러한 경우에 스프링 요소의 강성은 압축력을 재하한 실험적 연구에 의하여 산정되었다. 따라서, 상향력은 체결장치에 압축력뿐만 아니라 인장력도 유발시키기 때문에 합리적이고 정확한 구조해석을 수행하기 위해서는 인장력을 재하한 실험적 연구로부터 산정된 병진방향 강성 그리고 회전방향 강성을 함께 고려해야 한다. 본 연구에서는 6가지 실험체에 대하여 탄성과 비탄성 실험을 수행하여 레일 연직방향 병진강성과 레일 강축에 대한 회전강성을 검토하였고, 체결장치의 구조적인 거동을 분석하였다.

수직증축형 공동주택 리모델링 구조해석을 위한 PC말뚝 강성에 관한 연구 (A Study of Prestressed Concrete Pile Stiffness for Structural Analysis of Condominium Remodeling with Vertical Story Extension)

  • 최창호;이현지;최기선;유영찬;김진영
    • 한국지반공학회논문집
    • /
    • 제33권12호
    • /
    • pp.81-92
    • /
    • 2017
  • 2013년 주택법 개정에 따라 최대 3개층까지 공동주택의 수직증축 리모델링 사업이 가능해졌다. 수직증축 리모델링은 추가하중으로 인한 구조 안전성 및 강화된 내진기준을 만족해야 하므로 기초보강을 필요로 하며, 말뚝 보강설계에서는 기존 말뚝과 보강 말뚝의 하중분담을 고려해야 한다. 말뚝의 하중분담을 계산하기 위해서는 말뚝의 수직 강성($K_v$)이 필요하지만, 20~30년 전에 설치된 PC 말뚝 강성에 대한 연구는 매우 미미한 실정이다. 본 논문에서는 1990년대 아파트 신축시 수행된 38건의 현장 말뚝재하 시험 결과를 검토하여, 직경 및 길이의 변화에 따른 PC말뚝의 강성을 분석하였다. 분석 결과 말뚝강성은 장경비(L/D)가 증가함에 따라 감소하는 것으로 나타났다. 또한, 현장 말뚝재하 시험결과를 도로교설계기준해설(2008) 및 한국철도시설공단 말뚝기초의 설계(2012)에서 제안하고 있는 말뚝강성 산정을 위한 계수 'a'와 비교하였다. 비교결과 10

이중범프포일 공기베어링의 성능에 미치는 마찰효과 (Friction Effects on the Performance of Double-Bumped Air Foil Bearings)

  • 김영철;이동현;김경웅
    • Tribology and Lubricants
    • /
    • 제23권4호
    • /
    • pp.162-169
    • /
    • 2007
  • This paper deals with friction effects on the performance of double-bumped AFBs. The stiffness and damping coefficients of the double bump vary depending on the external load and its friction coefficient. The double bump can be either in the single or double active region depending on vertical deflection. The equivalent stiffness and damping coefficients of the bump system are derived from the vertical and horizontal deflection of the bump, including the friction effect. A static and dynamic performance analysis is carried out by using the finite difference method and the perturbation technique. The results of the performance analysis for a double-bumped AFB are compared with those obtained for a single-bumped AFB. This paper successfully proves that a double bumped AFB has higher load capacity, stiffness, and damping than a single-bumped AFB in a heavily loaded condition.