• Title/Summary/Keyword: vertical separation

Search Result 195, Processing Time 0.023 seconds

Numerical Study of Shadow Effect on Slab Deformation in Reheating Furnace (균열로의 그늘효과에 의한 슬랩변형에 관한 수치해석적 연구)

  • Noh, J.H.;Hwang, B.B.;Maeng, J.W.;Kim, J.D.
    • Transactions of Materials Processing
    • /
    • v.20 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • Three dimensional simulations were performed for the deformation of a slab in a roller hearth type slab reheating furnace. The main objective of this study was to examine the deformation pattern of the slab due to the shadow effect, i.e., the temperature difference between the upper and lower slab surfaces, in particular, the variations of displacement and effective stress in the vertical direction. A commercially available FE code, ANSYS Workbench $12.1^{TM}$, was used in a fully coupled thermo-elasticity analysis. Several cases with different slab surface temperatures were selected for the simulations. For the sake of simplicity, the temperature environment inside the furnace was assumed to be homogeneous for the upper and lower faces of the slab. Two cases of with different slab width were selected as model geometry. The deformation patterns were computed and explained in terms of periodicity and symmetry. The results indicated that the shadow effect leads to a significant displacement in the vertical direction and, thereby, is one of the main reasons for the separation of the slab and its supports. These simulations also predicted that the deformation is more severe along the transverse direction than along the longitudinal direction.

Vertical Integrated Transformer using Bondwires (본딩와이어를 이용한 수직형 집적 트랜스포머)

  • Song, Byeong-Uk;Lee, Hae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.3
    • /
    • pp.43-48
    • /
    • 2000
  • In this paper, vortical integrated transformers using bondwires are proposed and characterized for MMIC's (Monolithic Microwave Integrated Circuits) In a wide range of frequencies (1∼20 GHz), where full-wave analysis by the FEM (Finite Element Method) was adopted. The electrical characteristics of the proposed transformers are compared with those of the spiral transformer. We extracted mutual inductances from S -parameters. The vertical transformers using bondwires have not only low insertion loss but also reduce parasitic capacitances and dielectric loss due to their separation from substrates. It can be fabricated easily by used of the modern automatic wirebonding technology. It is expected that the proposed transformers are to improve the performance of MMIC's applied to impedance matching, and phase shifting circuits.

  • PDF

Modeling of Liquid Entrainment and Vapor Pull-Through in Header-Feeder Pipes of CANDU

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.142-152
    • /
    • 2004
  • The liquid entrainment and vapor pull-through offtake model of RELAP5/MOD3 had been developed for SBLOCA (Small Break Loss of Coolant Accident). The RELAP5/MOD3 model for horizontal volumes accounts for the phase separation phenomena and computes the flux of mass and energy through a branch when stratified conditions occur in the horizontal pipe. In the case of CANDU reactor, this model should be used in the coolant flow of 95 feeders connected to the reactor header component under the horizontal stratification in header. The current RELAP5 model can treat the only 3 directions junctions; vertical upward, downward, and side oriented junctions, and thus improvements for the liquid entrainment and vapor pull-through model were needed for considering the exact angles. The RELAP5 off-take model was modified and generalized by considering the geometric effect of branching angles. Based on the previous experimental results, the critical height correlation was reconstructed by use of the branch line connection angle and validation analyses were also performed using SET. The new model can be applied to vertical upward, downward and angled branch, and the accuracy of the new correlations is more improved than that of RELAP5.

Surgical Reconstruction of the Severe Tongue Laceration with Mandibular Fracture in a Siberian Husky Dog

  • Lee, Jae-Hoon;Kim, Tae-Hoon;Yang, Wo-Jong;Kang, Eun-Hee;Chang, Hwa-Seok;Chung, Dai-Jung;Choi, Chi-Bong;Lee, Jeong-Ik;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.545-548
    • /
    • 2008
  • A 3-year-old castrated male Siberian husky was presented for evaluation after being hit by a car. On physical examination, the dog showed open-mouth, displacement of mandible and hypersalivation with blood ting. The base of tongue was transected almost 80% on the bias from right dorsal side to the left ventral side. Radiography demonstrated separation of mandible symphysis, and fracture of right condyle and vertical ramus. After debridement of the necrotic tissue, tongue apposition with simple interrupted suture was performed. Mandibular symphysis, condyle and mandibular vertical ramus fractures were fixed using pin, cerclage wire, T-plate, and K-wires. The mouth was irrigated daily using chlorhexidine after surgery. The sutures that were loose here or untied at tongue were re-sutured under sedation. The transected tongue was healed and recovered its normal movement after 6 weeks.

A Numerical Study on Mixed Convection in Boundary Layer Flows over Inclined Surfaces (경사진 평판 주위에서 경계층유동의 혼합대류에 관한 연구)

  • 김동현;최영기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.725-733
    • /
    • 1990
  • An analysis of laminar mixed convection flow adjacent to the inclined flat surface which is subjected to a uniform temperature in a uniform free stream is performed. Nonsimilar boundary layed equation are derived by using the mixed convection parameters such that smooth transition from the purely forced convection limit to the purely free convection limit is possible. The governing equations are solved by a finite difference method using the coupled box scheme of sixth order. Numerical results are presented for prandtl numbers of 0.7 and 7 with the angle of inclination ranging from 0 to 90 degree from the vertical. The velocity distributions for the buoyancy assisting flow exhibit a significant overshoot above the free stream value in the region of intense mixed convection and the velocity field is found to be more sensitive to the buoyancy effect than the temperature field. The separation point near the wall was obtained for the buoyancy opposing flow. The local Nusselt number increases for buoyancy assisting flow and decreases for opposing flow with increasing value of the local Grashoff number in the mixed convection parameter. For large Prandtl number, the Nusselt number and the friction factor decrease significantly near the separation point. Present numerical predictions are in good agreement with recent experimental results by Ramachandran.

Effective Wavefield Separation of Reflected P- and PS-Waves in Multicomponent Seismic Data by Using Rotation Transform with Stacking (다성분 탄성파탐사자료에서 회전 변환과 중합을 이용한 효과적인 P파 반사파와 PS파 반사파의 분리)

  • Jeong, Soocheol;Byun, Joongmoo;Seol, Soon Jee
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.6-17
    • /
    • 2013
  • Multicomponent seismic data including both P- and PS-waves have advantages in discriminating the type of pore fluid, characterizing the lithologic attributes and producing the high resolution image. However, multicomponent seismic data recorded at the vertical and horizontal component receivers contain both P- and PS-waves which have different features, simultaneously. Therefore, the wavefield separation of P- and PS-waves as a preprocessing is inevitable in order to use the multicomponent seismic data successfully. In this study, we analyzed the previous study of the wavefield separation method suggested by Jeong and Byun in 2011, where the approximated reflection angle calculated only from one refernce depth is used in rotation transform, and showed its limitation for seismic data containing various reflected events from the multi-layered structure. In order to overcome its limitation, we suggested a new effective wavefield separation method of P- and PS-waves. In new method, we calculate the reflection angles with various reference depths and apply rotation transforms to the data with those reflection angles. Then we stack all results to obtain the final separated data. To verify our new method, we applied it to the synthetic data sets from a multi-layered model, a fault model, and the Marmousi-2 model. The results showed that the proposed method separated successfully P- and PS-reflection events from the multicomponent data from mild dipping layered model as long as the dip is not too steep.

Sensitivity analysis of input variables to establish fire damage thresholds for redundant electrical panels

  • Kim, Byeongjun;Lee, Jaiho;Shin, Weon Gyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.84-96
    • /
    • 2022
  • In the worst case, a temporary ignition source (also known as transient combustibles) between two electrical panels can damage both panels. Mitigation strategies for electrical panel fires were previously developed using fire modeling and risk analysis. However, since they do not comply with deterministic fire protection requirements, it is necessary to analyze the boundary values at which combustibles may damage targets depending on various factors. In the present study, a sensitivity analysis of input variables related to the damage threshold of two electrical panels was performed for dimensionless geometry using a Fire Dynamics Simulator (FDS). A new methodology using a damage evaluation map was developed to assess the damage of the electrical panel. The input variables were the distance between the electrical panels, the vertical height of the fuel, the size of the fire, the wind speed and the wind direction. The heat flux was determined to increase as the vertical distance between the fuel and the panel decreased, and the largest heat flux was predicted when the vertical separation distance divided by one half flame length was 0.3-0.5. As the distance between the panels increases, the heat flux decreases according to the power law, and damage can be avoided when the distance between the fuel and the panel is twice the length of the panel. When the wind direction is east and south, to avoid damage to the electrical panel the distance must be increased by 1.5 times compared to no wind. The present scale model can be applied to any configuration where combustibles are located between two electrical panels, and can provide useful guidance for the design of redundant electrical panels.

Finite element modeling for structure-soil interaction analysis of plastic greenhouse foundation (온실기초의 구조물-지반 상호작용 해석을 위한 유한요소 모델링)

  • Ryu, Hee-Ryong;Cho, Myeong-Whan;Yu, In-Ho;Moon, Doo-Gyung
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • In this study, structural behavior of plastic greenhouse foundation was investigated using rational finite element modeling for structures which have different material properties each other. Because the concrete foundation of plastic greenhouse and soil which surround and support the concrete foundation have very different material property, the boundary between two structures were modeled by a interface element. The interface element was able to represent sliding, separation, uplift and re-bonding of the boundary between concrete foundation and soil. The results of static and dynamic analysis showed that horizontal and vertical displacement of concrete foundation displayed a decreasing tendency with increasing depth of foundation. The second frequency from modal analysis of structure including foundation and soil was estimate to closely related with wind load.

Effect of Mandibular Reposition on Airway Resistance (하악의 위치 변화가 기도저항에 미치는 영향)

  • 최재갑;정태훈
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.65-73
    • /
    • 1998
  • This study evaluated whether substantial airflow resistance changes occurred by changing jaw position in normal and snoring subjects. A case-control design was utilized to assess group differences. Subjects included 11 snoring patients and 10 non-snoring subjects. Airway resistance was assessed using a whole body plethysmograph. Subjects in this study had their mouth opening standardized to a position of 7 mm of vertical separation and the resistance was measured under the following conditions; normal jaw position and 2/3 maximum protrusive jaw position. The results were as follows : 1. The airway resistance was higher in snoring group than in non-snoring group. 2. Both groups had a significant decrease in their airflow resistance upon jaw protrusion. In conclusion, these data document that airflow resistance can be significantly influenced by jaw positioning. Moving the jaw in a protrusive position produced reduction of resistance.

  • PDF

A Study of Determinants of Regulatory Policy of Air Traffic Management and Airspace Utility (항공교통관리와 국가공역의 규제정책 결정요인의 고찰)

  • Shin, Hyun-Sam
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.20 no.1
    • /
    • pp.255-272
    • /
    • 2005
  • This study was conducted to present the adaquate guidelines necessary in decision making processes regarding air traffic management as well as airspace management in the national airspace system. It encompasses the overall advanced air traffic management initiatives, domestic air traffic congestion and resolution method as well.

  • PDF