• 제목/요약/키워드: vertical characteristic

검색결과 536건 처리시간 0.023초

Identification of Pisolithus tinctorius from GNU Campus

  • ;;;;김희규
    • 농업생명과학연구
    • /
    • 제43권4호
    • /
    • pp.33-36
    • /
    • 2009
  • Globose to clavate base-ball sized, pear shaped, fruiting bodies were found under the Himalayan cedar, Cedrus deodora at less fertile and poor sandy poor soil in the campus of Gyeongsang National University in Jinju, Korea. The fruiting body was at first, round to club-shaped, usually with a narrow, rooting base with yellowish rhizomorphs attached to it and lack a volva and a sterile base. The peridium of fruiting body was tough and crusty. The peridioles were white pea-like capsules in a blackish matrix. The color change to darker tints of brown at the top of the exterior peridium reflected the gradual ripening of the interior gleba and peridioles, which proceeded from the top downward to become a mass of spore dust, appearing as cinnamon brown at the apex of the vertical section. At around this stage, the peridium cracked open linearly, exposing the gleba with powdery spores mass released from overmatured peridioles. Spores were more or less round, warty or spiny, 10 to $12{\mu}m$; globose, cinnamon brown in powdery mass, with spines up to $2{\mu}m$ long. The thin peridium ruptured further in response to the disintegration of the peridioles, releasing the powdery spores, which proceeded until whole fruiting body disappeared leaving the dry spore dust coats in the vicinity. The absence of a capillitium is a distinctive characteristic that distinguishes the specimen from other puff-ball fungi and from most of earthballs. Based on the above characteristics, the specimen was identified as Poslithus tinctorius.

피로효과를 고려한 레일패드의 정적스프링계수 변화에 따른 콘크리트 슬래브 제도의 거동분석 (A Behavior Analysis of HSR Concrete Slab Track under Variety of Rail Pad Static Stiffness on Fatigue Effect)

  • 박용걸;강기동;최정열
    • 한국철도학회논문집
    • /
    • 제10권5호
    • /
    • pp.499-505
    • /
    • 2007
  • 본 연구의 주목적은 고속선 콘크리트 슬래브 궤도시스템에서 레일패드의 피로효과에 따른 영향을 분석하는 데에 있다. 이에 3차원 해석모델 및 실내시험을 통해 도출된 레일패드의 피로효과(경화, 스프링계수 증가)가 고속선 궤도의 역학적 거동에 미치는 영향을 분석하였다. 본 연구에서는 콘크리트 슬래브 궤도의 적정 탄성력 확보여부를 의미하는 레일패드의 적정스프링계수 산정에 관한 연구의 일환으로 고속철도 콘크리트 슬래브 궤도에 적용된 레일체결시스템에 대한 실내시험을 통한 레일패드의 정적스프링계수를 산정하고 체결시스템에 대한 피로시험을 통해 도출된 피로효과가 고려된 레일패드의 스프링계수 변화를 해석모델에 적용함으로써 향후 고속선 콘크리트 슬래브 궤도운영에서의 열차 주행안정성 확보 및 합리적인 궤도유지관리를 위한 기초데이터를 확보하고자 한다.

가속열 노화로 열화된 탄성받침 고무재료의 전단 특성(2): 합성고무 (Shear Characteristics of Elastomeric Bearing Rubber Deteriorated by Accelerated Heat Aging(2): Chloroprene Rubber)

  • 선창호;김익현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.103-110
    • /
    • 2021
  • 유연한 고무재료와 강재 보강판을 적층으로 구성한 탄성받침은 우수한 수직강성과 유연한 횡강성으로 교량의 내진보강용으로 널리 사용되고 있다. 무엇보다 시공이 간단하고 비용이 높지 않다는 장점을 지니고 있다. 고무재료의 한 종류인 합성고무는 천연고무에 비해 노화에 대한 저항성이 크지만 이 역시 다양한 열화요인으로 성능이 저하된다. 내진설계기준 및 내진성능평가요령에서는 이러한 노화의 특성을 반영하고 있지 않지만 관련 연구가 축적되면 이를 반영하는 것이 합리적이다. 합성고무를 대상으로 노화촉진시간과 노출시간을 변수로 하여 노화촉진시험을 수행하여 전단특성의 변화를 분석하였다. 노화가 진행될수록 최대전단응력과 전단변형율은 감소한다. 또한 동일한 전단변형률에서 전단강성이 크게 증가한다.

베르누이 원리와 bolt-clamped Langevin type 초음파 진동자를 이용한 정상파 음파 공중부양의 탐구 (Investigation of standing wave acoustic levitation with Bernoulli principle and bolt-clamped Langevin type ultrasonic transducer)

  • 박민철;박두재;김영환
    • 한국음향학회지
    • /
    • 제37권6호
    • /
    • pp.422-427
    • /
    • 2018
  • 본 연구에서는 소형 물체가 음파 정상파의 압력 마디 부근에 소형 물체가 부양하는 정상파 음파 공중부양(standing wave acoustic levitation) 현상에 대해 베르누이 원리를 이용하여 부양의 원인이 되는 음향 방사힘(acoustic radiation force)의 근원과 개형을 기존에 알려진 진동자에서 떨어진 거리에 따른 음향 방사힘의 그래프와 비교함을 통해 개념적으로 설명했다. 이러한 설명을 뒷받침하는 일련의 실험들을 BLT(Bolt-clamped Langevin Type) 초음파 진동자를 이용해서 수행하여, 물체들이 공기의 압력 마디 부근에 부양하고 있음을 확인했고, 물체가 부양하고 있는 상태에서 정상파가 형성되는 조건임을 확인했다. 더불어, 정상파 음파 공중부양 현상에서 부양하는 물체들이 수직하게 일렬로 정렬하는 현상 역시 설명할 수 있었다.

모바일 기기를 위한 초소형 이중 교차 다이폴 안테나 설계 (Design of Ultra Small Dual Cross-Dipole Antenna for Mobile Devices)

  • 사기동;김사웅;임영석
    • 한국전자통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.489-496
    • /
    • 2019
  • 본 논문에서는 주파수 2.4 GHz에서 동작하는 초소형 이중 교차 다이폴 안테나를 설계 및 제작하였다. 모바일 기기에 적용할 수 있도록 안테나의 크기를 소형화하기 위해 교차 다이폴을 상부 2개 층에 배치하고 하부에 반사평면과 수평형 정합회로 및 그라운드 평면을 각 층에 배치한 구조에서 안테나와 급전부 및 정합회로는 수직 방향 관통비아홀로 연결하였다. 제작된 안테나의 크기는 $21.61mm{\times}16.88mm{\times}1.27mm$이며, 측정된 반사계수는 -31.5 dB이고, -10 dB 이하 대역폭은 112 MHz 이다. 또한 안테나의 이득은 -4 dBi로 무지향성의 방사 특성을 가지므로 모바일 기기용 안테나로 다양한 분야에 확대 적용될 수 있을 것으로 판단된다.

Radiation Monitoring in the Residential Environment: Time Dependencies of Air Dose Rate and 137Cs Inventory

  • Yoshimura, Kazuya;Nakama, Shigeo;Fujiwara, Kenso
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.30-38
    • /
    • 2022
  • Background: Residential areas have some factors on the external exposure of residents, who usually spend a long time in these areas. Although various survey has been carried out by the government or the research institutions after the Fukushima Daiichi Nuclear Power Plant accident, the mechanism of radiocesium inventory in the terrestrial zone has not been cleared. To better evaluate the radiation environment, this study investigated the temporal changes in air dose rate and 137Cs inventories (Bq/m2) in residential areas and agricultural fields. Materials and Methods: Air dose rate and 137Cs inventories were investigated in residential areas located in an evacuation zone at 5-8 km from the Fukushima Daiichi Nuclear Power Plant. From December 2014 to September 2018, the air dose rate distribution was investigated through a walking survey (backpack survey), which was conducted by operators carrying a γ-ray detector on their backs. Additionally, from December 2014 to January 2021, the 137Cs inventories on paved and permeable grounds were also measured using a portable γ-ray detector. Results and Discussion: In the areas where decontamination was not performed, the air dose rate decreased faster in residential areas than in agricultural fields. Moreover, the 137Cs inventory on paved surfaces decreased with time owing to the horizontal wash-off, while the 137Cs inventory on permeable surfaces decreased dramatically owing to the decontamination activities. Conclusion: These findings suggest that the horizontal wash-off of 137Cs on paved surfaces facilitated the air dose rate decrease in residential areas to a greater extent compared with agricultural fields, in which the air dose rate decreased because of the vertical migration of 137Cs. Results of this study can explain the faster environmental restoration in a residential environment reported by previous studies.

Galloping characteristics of a 1000-kV UHV iced transmission line in the full range of wind attack angles

  • Lou, Wenjuan;Wu, Huihui;Wen, Zuopeng;Liang, Hongchao
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.173-183
    • /
    • 2022
  • The galloping of iced conductors has long been a severe threat to the safety of overhead transmission lines. Compared with normal transmission lines, the ultra-high-voltage (UHV) transmission lines are more prone to galloping, and the damage caused is more severe. To control the galloping of UHV lines, it is necessary to conduct a comprehensive analysis of galloping characteristics. In this paper, a large-span 1000-kV UHV transmission line in China is taken as a practical example where an 8-bundled conductor with D-shaped icing is adopted. Galerkin method is employed for the time history calculation. For the wind attack angle range of 0°~180°, the galloping amplitudes in vertical, horizontal, and torsional directions are calculated. Furthermore, the vibration frequencies and galloping shapes are analyzed for the most severe conditions. The results show that the wind at 0°~10° attack angles can induce large torsional displacement, and this range of attack angles is also most likely to occur in reality. The galloping with largest amplitudes in all three directions occurs at the attack angle of 170° where the incoming flow is at the non-iced side, due to the strong aerodynamic instability. In addition, with wind speed increasing, galloping modes with higher frequencies appear and make the galloping shape more complex, indicating strong nonlinear behavior. Based on the galloping amplitudes of three directions, the full range of wind attack angles are divided into five galloping regions of different severity levels. The results obtained can promote the understanding of galloping and provide a reference for the anti-galloping design of UHV transmission lines.

대형직접전단시험을 이용한 조립재료의 전단거동 특성 (II) (Characteristic of Shear Behavior of Coarse Grained Materials Based on Large Scale Direct Shear Test (II))

  • 이대수;김경열;홍성연;황성춘
    • 한국지반공학회논문집
    • /
    • 제22권4호
    • /
    • pp.51-59
    • /
    • 2006
  • 본 고에서는 선행연구(홍성연, 2004)에서 개발한 대형직접전단시험기를 이용하여 조립질 토목재료의 시험밀도와 균등계수의 크기가 전단강도에 주는 영향을 분석하였으며, 아울러, 각 수직응력별로 한계상태에서 조립재료가 갖고 있는 마찰계수를 Wood(1998)가 제안한 방정식을 이용하여 산출하였다. 시험에 사용한 재료는 경상과 전라지역 석산에서 생산중인 조립재료이다. 시험결과 시험밀도 $2.10g/cm^3$의 전단강도의 크기가 $1.85g/cm^3$의 값보다 상대적으로 크게 나타났으며, 균등계수는 상대적으로 10.0보다 5.0일때 더 큰 전단강도를 갖는 것으로 나타났다. 한편, 조립질 토목재료가 갖고 있는 한계상태에서의 마찰계수는 각 시험조건별로 $1.0{\sim}1.6$의 범위로 나타났다.

연약지반에 시공된 Piled Raft 기초의 3차원 거동 분석 (Three Dimensional Numerical Analysis of Piled Raft on Soft Clay)

  • 이진형;정상섬
    • 한국지반공학회논문집
    • /
    • 제23권5호
    • /
    • pp.63-75
    • /
    • 2007
  • Piled raft 기초는 연약지반상에서 과도한 침하와 raft 및 말뚝의 지지력 산정 문제 등으로 적합한 기초는 아닌 것으로 알려져 왔으나 최근 국내외에서 연약지반내 구조물 시공이 증대되면서 연약지반상 piled raft 기초에 대한 관심이 커지고 있다. 이에 본 연구에서는 연약지반에 시공된 piled raft기초의 거동을 분석하였으며 이를 위해 ABAQUS를 이용한 3차원 유한요소 해석을 실시하였다. 해석 시 하중은 등분포하중과 집중하중을 각각 적용하였으며 동일한 조건의 군말뚝과 piled raft 기초 및 다양한 말뚝 배치를 갖는 piled raft 기초를 대상으로 수행하였다. 본 연구결과, 하중형태, 다양한 말뚝 배치 및 근입 깊이에 대한 각각의 침하 및 하중분담특성을 비교, 분석하였으며 이를 통해 연약지반상의 piled raft 기초의 특성을 파악하였다.

Topology optimization of bracing systems in buildings considering the effects of the wind

  • Paulo U. Silva;Rayanne E.L. Pereira;Gustavo Bono
    • Structural Engineering and Mechanics
    • /
    • 제86권4호
    • /
    • pp.473-486
    • /
    • 2023
  • Nowadays, urban centers are increasingly vertical, making architects and engineers look for more efficient tools to analyze the effects of wind on tall buildings. Topology optimization can be used as an efficient tool for the design of bracing systems. Therefore, this work obtained the wind loads that act in the CAARC building, following the Brazilian standard NBR 6123/1988 and using Computational Fluid Dynamics. Four loading situations were considered, using the SIMP and BESO methods to optimize two-dimensional structures. A comparison between the SIMP and BESO methods is presented, showing the differences in the geometry of the solution found by both methods, the percentage variation in the objective function values and the dimensionless processing time. The solutions obtained through the loads obtained by the Brazilian standard are also compared with the numerical solutions obtained by CFD. The results show that the BESO method presented more rigid structures compared to the SIMP method. The bracing structures obtained with the SIMP method always present similar patterns in the distribution and quantity of bars, in contrast to the BESO method where no characteristic topology pattern was observed. It was concluded that even though the structures obtained by the BESO method presented greater stiffness, the SIMP method was less susceptible to the methodology used for the determination of wind loads. Additionally, it was evident the great potential that the combination topology optimization and computational wind engineering have in the design of bracing systems of high functional and aesthetic standards.