• Title/Summary/Keyword: verification type

Search Result 941, Processing Time 0.026 seconds

One-stop Platform for Verification of ICT-based environmental monitoring sensor data (ICT 기반 환경모니터링 센서 데이터 검증을 위한 원스탑 플랫폼)

  • Chae, Minah;Cho, Jae Hyuk
    • Journal of Platform Technology
    • /
    • v.9 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • Existing environmental measuring devices mainly focus on electromagnetic wave and eco-friendly product certification and durability test, and sensor reliability verification and verification of measurement data are conducted mainly through sensor performance evaluation through type approval and registration, acceptance test, initial calibration, and periodic test. This platform has established an ICT-based environmental monitoring sensor reliability verification system that supports not only performance evaluation for each target sensor, but also a verification system for sensor data reliability. A sensor board to collect sensor data for environmental information was produced, and a sensor and data reliability evaluation and verification service system was standardized. In addition, to evaluate and verify the reliability of sensor data based on ICT, a sensor data platform monitoring prototype using LoRa communication was produced, and the test was conducted in smart cities. To analyze the data received through the system, an optimization algorithm was developed using machine learning. Through this, a sensor big data analysis system is established for reliability verification, and the foundation for an integrated evaluation and verification system is provide.

The Design and Performance Verification of Collocated Capacitance Sensor for Magnetic Bearing (자기베어링과 공위한 축전센서의 설계 및 성능 평가)

  • 유선중;신동원;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.317-322
    • /
    • 1994
  • The design and performance verification of collocated capacitance sensor system for magnetic bearing is presented. Noncollocation between actuators and sensors may cause unstable rotor behavior. The capacitance sensor is not affected by magnetic field. PCB type capacitance sensor is installed between magnetic bearing polse. so, collocation of sensors and actuators can be achieved. Experiment of sensor's static and dynamic charactistics is conducted. Modeling of the rotor system supported by magnetic bearing is made. And performance comparison between simulation and experiment is showed.

  • PDF

Risk Level Analysis of Architectural Work using AHP (AHP를 이용한 건축건설공사 공종별 위험도 분석)

  • Kim, Jeongmin;Lee, Jong-Bin;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.96-102
    • /
    • 2017
  • The highest fatal accident ratio was recorded in the construction industry. According to the industrial insurance premium rate & business type example, among the construction industry, the architectural work has the highest fatal and loss time accident ratio. Previous literature has investigated various aspects of accident occurrence and prevention in architectural work. However, those studied were limited in that they only focused on the fatal accident without considering the loss time accident. But non fatal accidents were recorded more than 50 times of fatal accidents. Therefore non fatal accidents must be controlled to lessen industrial accidents. Based on this, the goal of this study was to investigate the nature of the loss time accident and derive the risk index of work type in architectural work. In this study, opinions of safety experts were gathered and the risk index of work type was derived using AHP(Analytic Hierarchy Process). And verification was accomplished by comparing the results of this study with the risk index derived by analysis of accident records. Results showed that the risk index of work type was significantly higher in steel frame work, temporary installation work, earth & foundation work, facilities work, concrete work. And statistical analysis for verification showed that coefficient of Pearson correlation was 0.686 and P-value was 0.001.

Development of Removable Soil Nail (제거식 쏘일 네일 개발 및 성능 평가)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Kim, Ung-Jin;Kim, Woong-Kyu;Cho, Kyu-Wan;Sin, Sang-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.896-901
    • /
    • 2009
  • A Soil Nail is a structural element which provides load-transfer to the ground in excavation reinforcement applications. The nail may simply consist of a steel tendon, but most commonly the tendon is encapsulated in a cement grouted body to provide corrosion protection and improved load- transfer to the ground. For temporary excavation support in a congested urban area, the steel bar of Soil Nails should be removed to get permission of the private land to install Soil Nails. Several removable nail systems were developed and evaluated by pull-out load tests. The Soil Nail pull-out tests were performed on five nails installed in soft and hard rock at a 00 housing-redevelopment area in seoul. Two nails are plastic socket type and two are complex socket type mixed steel and plastic. The nail was 0.1mm in diameter, 4m long. In this study verification tests, and steel bar removing tests of plastic socket type nails and complex socket type nails were performed and presented.

  • PDF

Development and Verification of Treatment Programs by Turn and Roll Types to Improve the Function of Vestibular System (전정기 기능 향상을 위한 회전과 구르기 훈련 프로그램의 개발 및 검증)

  • Park, Yang-Sun;Kang, Sung-Ho;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.209-217
    • /
    • 2012
  • The purpose of this study was to develop a turn-type treatment program which applies the principle of spotting and a roll-type treatment program that induces off-vertical axis. 29 collegiate students volunteered for this study. 12-week treatment programs were applied to both 15 students for turn-type treatment group and 14 students for roll-type treatment group. As an analytic tool, eye camera was employed to verify the treatment programs for a stimulus upon a turn, recovery after a stimulus upon a turn, and nystagmus that affects a vestibular system. Two-way ANOVA with repeated measures was applied to see the significant differences between the treatment groups, and between the test periods. For Post-Hoc Test, paired t-test was used to within the group and independent t-test was used to between the groups. The results indicated that roll-type treatment training has maximized a stimulus on nystagmyus during the stimulus by a roll. Turn-type treatment training has maximized a stimulus on nystagmyus right after a stimulus by a roll and significantly decreased the intensity of nystagmyus during the recovery. Both turn and roll type treatments have reduced the recovery time which from nystagmyus to a normal status. Roll-type treatment has showed a much shorter recovery time for nystagmyus than the roll-type treatment has. Based on the results of treatment programs developed in this study, we expect the treatment programs can be applied to treat dizziness and to improve the function of vestibular system as a rehabilitation tool.

Drop Test for the UAV Landing Gear Performance Verification (무인정찰기 착륙장치 성능입증을 위한 낙하시험)

  • Shin, Jeong-Woo;Lee, Seung-Gyu;Yang, Jin-Yeol;Kim, Sung-Joon;Hwang, In-Hee;Chung, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.250-254
    • /
    • 2011
  • Main role of landing gear is to absorb the energy which is generated by aircraft lanidng and ground maneuvering. Generally, in order to absorb the impact energy during landing, oleo-pneumatic type shock absorber is used for aircraft landing gear. Oleo-pneumatic type shock absorber has a good energy absorbing efficiency and is light in weight because its structure is relatively simple. For the landing gear development, it is necessary to conduct drop test in order to verify shock absorbing performance. In the drop test, first, gas spring curve verification tests are conducted. Then, limit and reserve energy absorption drop tests are performed based on the STANAG 4671. The drop tests results with performance analysis results are presented.

  • PDF

Experimental Performance Verification of Load Carrying Capacity Algorithm of Bridges using Ambient Vibration (상시진동을 이용한 교량 내하력 추정 알고리즘의 실험적 성능 검증)

  • Lee, Woo-Sang;Park, Ki-Tae;Han, Sung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.83-90
    • /
    • 2010
  • In this study, it is conducted that the performance verification of the ambient load carrying capacity algorithm using long-term measurement systems of bridges. For this purpose, a steel-box type model bridge is fabricated and the public load carrying capacity of a steel-box model bridge is estimated by conducting the numerical analysis and load test. In addition, we compare the public load carrying capacity with the estimated result of a steel-box model bridge using the ambient load carrying capacity algorithm. By the assessment result, it is shown that the estimated ambient load carrying capacity is the difference of approximately 6.0 percentages as compared with the public load carrying capacity.

Development for Verification Tool Guaranteeing Reliability of Rail Signal Control Protocol (신뢰성확보를 위한 철도 신호제어용 프로토콜 검정기 개발)

  • Seo, Mi-Seon;Hwang Jin-Ho;Hwang Jong-Gyu;Lee Jae-Ho;Kim Sung-Un
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1452-1455
    • /
    • 2004
  • In this paper, we develope a protocol verification tool that verifies the correctness of rail signal control protocol type 2 specified in LTS(Labeled Transition System) by using model checking method. This tool automatically checks several properties for deadlock, livelock and reachability of states and actions on LTS. and removes many errors and ambiguities of an informal method used in the past, so saves down expenditures and times required in the protocol development. Therefore it is expected that there will be an increase in safety, reliability and efficiency in terms of the maintenance of the signaling system by using the developed verification tool.

  • PDF