• Title/Summary/Keyword: ventilating

Search Result 226, Processing Time 0.037 seconds

The Characterization of Carbonyl Compounds in the Newly-Built Schools, Daegu City (대구지역 신축학교 실내공기 중 카보닐화합물의 농도 특성 평가)

  • Hwang, Yoon-Jung;Park, Hee-Sun;Jang, Seong-Il;Roh, Ki-Cheul;Son, Tae-Jung;Han, Jeong-Wook;Bae, Gi-Soo;Choi, Im-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.831-841
    • /
    • 2006
  • The study on school indoor air quality was carried out at classrooms, computer-rooms, laboratories and play- grounds for carbonyl compounds including formaldehyde during the winter time from November to December 2004 and during the summer time from June to July 2005. The sampling was conducted under the general school condition without any artificial intervention such as the sealing, ventilating or heating at indoor environments. The concentrations of formaldehyde at all types of indoor environments were lower than air quality standard of $120{\mu}g/m^3$ for public facilities. The mean concentrations of formaldehyde at indoors were $4.5{\sim}6.1$ times higher than those at outdoors. From the comparison between two year and one year old schools after construction, the concentrations of formaldehyde in two year old school were $30{\sim}38%$ lower than those in one year old school measured at classrooms and laboratories.

Interior Environment and Practical Usages of the Home Economics Practice Room in Middle School of Gyeonggi and Incheon (경기$\cdot$인천지역 중학교 가정실 실내 환경과 활용 실태)

  • Cho Jae Soon;So Bok Ryea
    • Journal of Korean Home Economics Education Association
    • /
    • v.16 no.4 s.34
    • /
    • pp.127-140
    • /
    • 2004
  • The purpose of this study was to find out the interior environment, teaching equipments and tools, practical usages and related problems of the Home Economics practice room as a special room of Home Economics in middle school. The data were collected with questionnaire through a mail from 150 teachers charged in the Technology $\cdot$ Home Economics of the middle schools in the Gyeonggi Province and Incheon Metropolitan City. There were Home Economics practice rooms in the most of the middle schools. The room was used for the Home Economics class as well as for many other activities. which sometimes disturbed the class in the room. The frequency of the usage of the room was relatively low and limited mostly to the cooking class and somewhat sewing class because of the lack of environmental equipment and facilities such as heating, cooling. ventilating systems and furnishings such as table. chair as well as teaching materials. etc. Teachers wanted to use the room for all units of the Home Economics class applied to various teaching methods in the room. The improvement of the interior environments and teaching materials could facilitate the variety of the class in the Home Economic practice room.

  • PDF

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy (초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰)

  • Lee, Hoon-Jeong;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1057-1064
    • /
    • 2021
  • This study was conducted by simulating the same environmental conditions as the actual biopsy to observe the change in formaldehyde(HCHO) concentration in the indoor air during ultrasound guided biopsy. Changes in HCHO concentration in the room were measured by successively performing five steps: sealing the ultrasound room, ventilation, opening formalin containers, sealing formalin containers, and re-ventilating. Trends of measured HCHO concentration changes were visualized using graphs. As a result of analyzing the consistency of the concentration change values measured three times using the intra-class correlation coefficient, it was found to be 0.989, which was statistically significant(p<0.05). Based on the results of this study, we hope that medical workers working in the HCHO exposure environment of the field of radiology part will improve their awareness of the necessity of exposure management at work, and actively discuss the establishment of an environment for exposure control and preparation of countermeasures.

Work Conditions and Practices in Norwegian Fire Departments From 1950 Until Today: A Survey on Factors Potentially Influencing Carcinogen Exposure

  • Jakobsen, Jarle;Babigumira, Ronnie;Danielsen, Marie;Grimsrud, Tom K.;Olsen, Raymond;Rosting, Cecilie;Veierod, Marit B.;Kjaerheim, Kristina
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.509-516
    • /
    • 2020
  • Background: Meta-analyses have shown firefighters to be at an increased risk of several cancer types. Occupational carcinogen exposure may explain these increased risks. This study aims to describe Norwegian fire departments' work conditions from 1950 until today, focusing on factors relevant for potential occupational carcinogen exposure. Methods: With the help of a reference group, we developed a questionnaire on topics related to occupational exposure to carcinogens for the period 1950-2018. Selected Norwegian fire departments provided department-specific responses. Results: Sixteen departments, providing fire services for 48% of the Norwegian population as of 2019 and mainly consisting of professional firefighters, responded to our questionnaire. The introduction of synthetic firefighting foams, more regular live fire training, the introduction of chemical diving, and a higher number of diesel-driven fire service vehicles were identified as changes thought to increase exposure to occupational carcinogens. Changes thought to decrease exposure included the switch from negative to positive pressure self-contained breathing apparatuses, the use of self-contained breathing apparatuses during all phases of firefighting, the use of ventilating fans during firefighting, increased attention to flammable materials used during live fire training, increased attention to handling and cleaning of turnout gear and other equipment, and installment of exhaust removal systems in apparatus bays. Conclusion: Norwegian fire departments' work conditions have seen several changes since 1950, and this could influence firefighters' occupational carcinogen exposure. A peak of carcinogen exposure may have occurred in the 1970s and 1980s before recent changes have reduced exposure.

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

Study on the Exposure Levels of Organic Solvents and Subjective Symptoms of Dry-cleaning Workers (드라이클리닝 근로자들의 유기용제 폭로와 자각증상)

  • Kim, Soo-Young;Kim, Jeong-Yun;Lee, Yeon-Kyeng;Lee, Sok-Goo;Lee, Young-Soo;Cho, Young-Chae;Lee, Tae-Young;Lee, Dong-Bae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.628-643
    • /
    • 1998
  • To investigate the exposure levels of organic solvents and subjective symptoms of dry-cleaning workers, 77 male and 52 female dry-cleaning workers who had been worked in a small city of Chungnam province, and a large city, Taejon were selected for the study group. Air concentrations of organic solvents in the working environment were analyzed, and subjective symptoms of dry-cleaning workers were surveyed, from July to August 1996. The results obtained were as follows : 1. The concentrations of organic solvents in the working environment were within permissible TLV-TWA limits. 2. For the 13 symptom clusters, the most frequently complained symptom clusters were fatigue as 71.3%, and followed by depression and urinary disturbances as 53.5% and 51.9%. Other symptom clusters complained were below 50%. 3. Positive response rates of subjective symptoms were significantly higher in worker groups such as lived in a large city, female, higher education level, more frequently alcohol drinking, higher concentration of organic solvent in working environment, work in alone. 4. Workers who had used solvent B showed 2.3 point higher scores of subjective symptoms than those of solvent A. Of the subjective symptoms scores, amnesia and nervousness were higher in solvent B user group than solvent B user group. 5. As a result of factor analysis, 3 factors such as depression, urinary disturbance and neurologic disturbance were selected. 6. As a result of the logistic regression analysis, sex, the number of fellow workers, working time, region, job tenure, smoking, alcohol drinking, ventilating system, concentration of organic solvent in working environment and place of residence were selected for the related variables. For the conclusion, even though the concentrations of organic solvents in the working environments of dry-cleaning workers were within permissible limit of TLV-TWA, many dry-cleaning workers complained symptoms, such as fatigue, depression, urinary disturbances and so on. And the factors affecting to the symptoms of dry-cleaning workers were the number of fellow workers, work hours, region, job tenure, smoking and alcohol drinking.

  • PDF

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.