• Title/Summary/Keyword: vehicle fire

Search Result 301, Processing Time 0.026 seconds

A Study on a utilizing Mobile Mapping System for establishing the High Speed Outdoor Positioning DB based on Field Check Data (정위치 기반 고속 실외 측위 DB 구축을 위한 MMS활용 방안에 관한 연구)

  • Lee, Ha Dong;Lee, Yun;Choi, Yun Soo;Jeong, In Hun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.31-37
    • /
    • 2017
  • Recently, governmental authority and local government are looking for a method of utilizing location information of smart phone for urgent rescue in fire and kidnap situation. Under this background, in this study, a method of rapidly collecting, constructing location determination based Wi-Fi AP data utilizing location information of smart phone and mobile mapping system was suggested in order to construct precise positioning information that could be utilized under urgent situation. By performing compensation work for GPS/INS/DMI through collected outcome, position of collected vehicle was acquired. In addition, source data integrating Wi-Fi information and collected position by coupling based on Wi-Fi AP collector and GPS time was constructed and Wi-Fi radiomap was constructed by removing Wi-Fi signal noise that reduces precise position performance. As a result of performing location determination performance assess ment by selecting 10 test positions by each local government, result value of 25.46cm for total local government average and 27.76m for SD could be obtained. It is considered that this result could be utilized as a technology of being able to supplement or substituting GPS location determination technology that is impossible in plocation determination of mobile communication company's base station (200m~2km) and indoor being used at present.

Change of Statical Behavior and Ultimate Capacity of Steel Cable-stayed Bridges after Cable Failure (케이블 단선 후 강사장교의 구조 및 극한 거동 변화)

  • Kim, Seung-Jun;Choi, Jun-Ho;Won, Deok-Hee;Han, Taek-Hee;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.747-761
    • /
    • 2011
  • This paper presents an investigation on the change in the statical behavior and the ultimate capacity of steel cable-stayed bridges after cable failure. Cable failure can occur due to fire, direct vehicle clash accidents, cable or anchorage fatigue, and so on. Moreover, the cable may be temporarily disconnected during cable replacement work. When cable failure occurs, the load, that was supported by the broken cable is first transferred to another cable. Then the structural state changes due to the interaction between the girder, mast, and cables. Moreover, it can be predicted that the ultimate capacity will decrease after cable failure, because of the loss of the support system. In this study, the analysis method is suggested to find the new equilibrium state after cable failure based on the theory of nonlinear finite element analysis. Moreover, the ultimate analysis method is also suggested to analyze the ultimate behavior of live loads after cable failure. For a more rational analysis, a three-step analysis procedure is suggested and used, which consisted of initial shape analysis, cable failure analysis, and live load analysis. Using this analysis method, an analytical study was performed to investigate the changes in the structural state and ultimate behavior of steel cable-stayed bridges.

Design of Disaster Control System based on 4S Kernel Component (4S 핵심 컴포넌트 기반의 재난재해 시스템 설계)

  • Joo, In-Hak;Lee, Seung-Yong;Oh, Byoung-Woo;Kim, Min-Soo
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.1 s.5
    • /
    • pp.27-36
    • /
    • 2001
  • The 4S represents four systems that are commonly related to spatial information: GIS, GNSS, SIIS, ITS. The 4S technology that integrates the four systems gets more and more interests recently. In this paper, we adopt component paradigm to 4S system, apply it to the disaster control field, and design a system based on component architecture. There are many application areas to which the 4S technology can be applied. but the disaster control system is one of the most typical fields. We apply 4S technology to the disaster control fields, including fire, flood, and typhoon. Because of the characteristics of disaster control system that handles large-volume map data, component-based 4S system will take considerable effects on the improvement of disaster control works. The core functions that are common to all disaster control fields are included in 4S kernel component because of the consideration of time performance. Remaining non-common functions are implemented as separate components named as work-specific components. In our suggested system, a vehicle named as 4S-Van collects real-time information on the spot of disaster and sends image and location information to control center via wireless transmission. The control center analyzes the information together with its own spatial database or map, which was not possible in the conventional disaster control works. The control center can get desired information by sending a request of re-transmission to 4S-Van. Such method of real-time transmission supported by on-the-spot information makes the current situation judgment, decision making, and order issuance more exact, effective, and timely. The suggested system and method are expected to bring remarkable improvement on disaster control works.

  • PDF

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process (시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어)

  • Lee, Seung-Chul;Kim, Soo-Chang;Noh, Kwang-Chul;Park, Myoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.463-469
    • /
    • 2009
  • We performed the experimental study on the control of suspended dust in a cement packaging process for various ventilation systems. To effectively remove the dust generated in the cement packaging process, three different kinds of ventilation system, such as local exhaust ventilation, electrostatic scrubber, and local air supply system, were adopted. Dust concentrations in the packaging process were measured with the variation of the airflow rate of the ventilation systems and then their ventilation performance were evaluated. From the results, we knew that the ventilation performance was the best when the local exhaust ventilation and the electrostatic scrubber were simultaneously operated in the packaging process. In the electrostatic scrubber system, the effect of the airflow rate on the indoor dust removal efficiency was negligible so hat he system ust be operated at $2,700m^3/h$ for saving power consumption.

A Study on Lawsuit Cases and Measures of Emergency Medical Service (응급의료서비스 중 발생되는 소송사례와 대책 연구)

  • Kwon, Hay-Ran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.77-90
    • /
    • 2009
  • Civil complaints and lawsuits filed in the process of providing emergency medical service include fall accident on the way of carrying the patient, transfer consent, refusal and rejection of rescue request, range and behavior restriction of emergency medical technicians, false registry of logbook, neglect of duty and emergency patient, and violation of traffic laws on the way of dispatch to the scene of accident. This study suggested the measures by cases as follows. 1. The accidents on the way of carrying a patient could be divided into fall of patient and fall by paramedic's mistake. In the former case, damages caused by the ambulance's shaking must be notified to the patient and guardian and recommended to fasten seat belt, in the latter case, the plan of patient's posture, route of transport, rescue and equipments should be comfirmed before fixing the patient. 2. Transfer consent must be made as implied when the patient is unconscious under delusion and was not able to consent physically, and paramedic must take an action by his judgment and record details of services on logbook. 3. When a patient refused to transfer, get 'confirmation of transfer refusal' and inform him of refusal. Paramedic should receive the signature. In addition, in case of refusal, transfer request should be made after hearing doctor's opinion and it should be notified to transfer request and superintendent of fire station after making 'confirmation of transfer refusal'. 4. Emergency medical technicians should perform their duties within the range of services prescribed by Article 41 of Law of Emergency Medical Service and Article 33 of Its Enforcement Regulations and shall not make announcement of death. In case of reporting the death to guardian, it is desirable to use record data like ECG results. 5. The best way to have protection from legal problems is making and keeping the exact records of accident and patient. Paramedic should not mention his subjective opinion about the accident-related matter. He must record correctly and keep the original medical records. 6. As emergency medical technicians are responsible for taking care of emergency patients, they must contact a briefing room when they meet a difficult situation suddenly due to vehicle stop or treatment of other patients and then must have support from neighboring hospital and other safety centers. 7. Since the ambulance operator is responsible for safety and careful driving of ambulance, he must be careful when he violates traffic regulations unavoidably. The operator should drive slowly below 10km/h at an intersection and pass it after getting way from general vehicles driving from all directions.

  • PDF

Development of FCEV accident scenario and analysis study on dangerous distance in road tunnel (도로터널에서 수소차 사고시나리오 개발 및 위험거리에 대한 분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.659-677
    • /
    • 2022
  • Hydrogen is emerging as a next-generation energy source and development and supply of FCEV (hydrogen fuel cell electric vehicle) is expected to occur rapidly. Accordingly, measures to respond to hydrogen car accidents are required and researches on the safety of hydrogen cars are being actively conducted. In this study, In this study, we developed a hydrogen car accident scenarios suitable for domestic conditions for the safety evaluation of hydrogen car in road tunnels through analysis of existing experiments and research data and analyzed and presented the hazard distance according to the accident results of the hydrogen car accident scenarios. The accident results according to the hydrogen car accident scenario were classified into minor accidents, general fires, jet flames and explosions. The probability of occurrence of each accident results are predicted to be 93.06%, 1.83%, 2.25%, and 2.31%. In the case of applying the hydrogen tank specifications of FCEV developed in Korea, the hazard distance for explosion pressure (based on 16.5 kPa) is about 17.6 m, about 6 m for jet fire, up to 35 m for fireball in road tunnel with a standard cross section (72 m2).

Effect on self-enhancement of deep-learning inference by repeated training of false detection cases in tunnel accident image detection (터널 내 돌발상황 오탐지 영상의 반복 학습을 통한 딥러닝 추론 성능의 자가 성장 효과)

  • Lee, Kyu Beom;Shin, Hyu Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.419-432
    • /
    • 2019
  • Most of deep learning model training was proceeded by supervised learning, which is to train labeling data composed by inputs and corresponding outputs. Labeling data was directly generated manually, so labeling accuracy of data is relatively high. However, it requires heavy efforts in securing data because of cost and time. Additionally, the main goal of supervised learning is to improve detection performance for 'True Positive' data but not to reduce occurrence of 'False Positive' data. In this paper, the occurrence of unpredictable 'False Positive' appears by trained modes with labeling data and 'True Positive' data in monitoring of deep learning-based CCTV accident detection system, which is under operation at a tunnel monitoring center. Those types of 'False Positive' to 'fire' or 'person' objects were frequently taking place for lights of working vehicle, reflecting sunlight at tunnel entrance, long black feature which occurs to the part of lane or car, etc. To solve this problem, a deep learning model was developed by simultaneously training the 'False Positive' data generated in the field and the labeling data. As a result, in comparison with the model that was trained only by the existing labeling data, the re-inference performance with respect to the labeling data was improved. In addition, re-inference of the 'False Positive' data shows that the number of 'False Positive' for the persons were more reduced in case of training model including many 'False Positive' data. By training of the 'False Positive' data, the capability of field application of the deep learning model was improved automatically.

A Study for Failure Examples Including with Timing Belt, Camshaft Position Sensor and Ignition Coil Damage of LPG Vehicle Engine (액화석유가스 자동차 엔진의 타이밍벨트, 캠샤프트포지션센서, 점화코일 손상과 관련된 고장사례에 대한 연구)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Kim, Jee Hyun;Lee, Jae Gang;Han, Seung Min;Hwang, Woo Chan;Hwang, Han Sub;Moon, Hak Hoon;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.54-59
    • /
    • 2022
  • This paper is a purpose to study and analyze the failure examples for timing belt, camshaft position sensor and ignition coil of LPG automotive engine. The first example, whe the service man install the front case bracket of engine, he excessively tightened up a 12mm bolt for being fixed of brackct. As a results, the bolt was separated from joint part so that it was put in between the crankshaft sprocket. Therefore the belt was broken off because of interference between timing belt and sprocket tooth. The second example, it verified the disharmony phenenomen of engine that the gap of the camshaft position sensor and camshaft senseing point assembled on cylinder head part was small more than iregular value so that the it was generated senseing damage phenomenon by pulse signal misconduct. The third example, it was found the engine disharmony phenomenon that the fire in the ignition coil was leaked by inner damage of Number 2 ignition coil.Therefore, the the manager of a car throughtly have to inspect not in order to arise the failure symptoms.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.