• Title/Summary/Keyword: vascular stent

Search Result 49, Processing Time 0.034 seconds

Application of Ultrasonic Nano Crystal Surface Modification into Nitinol Stent Wire to Improve Mechanical Characteristics (나이티놀 스텐트 와이어의 기계적 특성 향상을 위한 초음파 나노표면 개질 처리에 대한 연구)

  • Kim, Sang-Ho;Suh, Tae-Suk;Lee, Chang-Soon;Park, In-Gyu;Cho, In-Sik;Pyoun, Young-Shik;Kim, Seong-Hyeon
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.80-87
    • /
    • 2009
  • Phase transformation, superelastic characteristics and variation of surface residual stress were studied for Nitinol shape memory alloy through application of UNSM technology, and life extension methods of stent were also studied by using elastic resilience and corrosion resistance. Nitinol wire of ${\phi}1.778$ mm showed similar surface roughness before and after UNSM treatment, but drawing traces and micro defects were all removed by UNSM treatment. It also changed the surface residual stress from tensile to compressive values, and XRD result showed less intensive austenite peak and clear martensite and additional R-phase peaks after UNSM treatment. Fatigue resistance could be greatly improved through removal of surface defects and rearrangement of surface residual stress from tensile to compressive state, and development of surface modification system to improve not only bio-compatability but also resistance to corrosion and wear will make it possible to develop vascular stent which can be used for circulating system diseases which run first cause of death of recent Koreans.

  • PDF

Hybrid Palliation for Functionally Single Ventricle with Systemic Outflow Obstruction (단심증에서의 Hybrid 고식술)

  • Cho, Won-Chul;Song, Kwang-Jae;Jung, Sung-Ho;Kim, Young-Hwee;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.927-930
    • /
    • 2006
  • Hybrid procedure was performed for a thirteen-day-old girl with a functionally single ventricle, who weighed 2.2 kg and had been prematurely born at $32^{+5}$ weeks of gestation. She underwent bilateral pulmonary artery banding using 3.5 mm Gore-Tex graft, ductal stenting using balloon expandable stent, and reverse Blalock-Taussig shunt with 3.5 mm Gore-Tex vascular graft. After discharge, she was followed up for 4 months, and underwent 2nd stage operation(extensive arch reconstruction with Damus-Kaye-Stansel anastomosis, atrial septectomy, bilateral pulmonary artery angioplasty, bidirectional cavopulmonary shunt). She has been followed up for 4 months after the 2nd operation with an excellent clinical condition.

Iatrogenic Ureteral Injury: When and How to Treat? (의인성 요관손상: 언제, 어떻게 치료할 것인가?)

  • Seo, Kang Il;Lee, Jong Bouk
    • Journal of Trauma and Injury
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2008
  • Iatrogenic ureteral injury is a complication that can occur during a variety of pelvic or abdominal surgeries. The most frequent causes are gynecological ones, followed by colon and vascular surgeries. Management of ureteric injury depends on the time of diagnosis and the severity of organ damage. Injuries diagnosed intraoperatively should be treated immediately. Occasionally, intraoperative ureteral injury is overlooked, and symptoms of the late diagnosis of ureteral injury are usually nonspecific; therefore, the diagnosis is delayed for days or weeks postoperatively. Management of injuries diagnosed postoperatively is more complex. There are differing opinions on whether an initial conservative or immediate operative intervention is the best line of action. Delayed repair is suggested on the grounds that it will reduce inflammation and tissue edema. However, many authors are in favor of early repair, perhaps because tissue planes are easier to find before fibrosis becomes too dense. Ureteral injuries occurring at the level of the pelvic brim should be best managed with an end-to-end anastomosis, preferably around a ureteric stent. More distal injuries also should be ideally managed with an end-to-end anastomosis, after excision of the crushed or compromised segments. However, if the remaining distal segment is short, ureteral reimplantation is the procedure of choice. The Boari flap technique for ureteral reimplantation is invaluable in cases with a short proximal segment. Delayed recognition of iatrogenic ureteral injury may be associated with serious complications, so prompt recognition of ureteral injuries is important. Recognition of the injury before closure is the key to easy, successful, and complications-free repair. Increased awareness of the risk for ureteral damage during certain operative maneuvers is vital to prevent injury, and to decrease the incidence of iatrogenic injury. A sound knowledge of abdominal and pelvic anatomy is the best prevention.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

A Case of Renovascular Hypertension Due to Renal Artey Stenosis Related to Moyamoya Disease (모야모야병과 동반된 신 동맥 협착에 따른 신성 고혈압을 보인 1례)

  • Kim, Joung-A;Kim, Seung;Kim, Hyo-Sun;Shin, Jae-Il;Jeong, Il-Cheon;Kim, Dong-Seok;Kim, Myung-Joon;Lee, Do-Yun;Lee, Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.294-298
    • /
    • 2007
  • Moyamoya disease is a progressive cerebrovascular disorder with stenosis or occlusion of the bilateral internal carotid arteries with abnormal vascular networks at the base of the brain. Previous reports have shown that there are extracranial vascular involvements in Moyamoya disease, especially in the renal artery. We report a 7-year-old patient with Moyamoya disease associated with renovascular hyper tension, who presented in infancy with seizures and hemiparesis. Renal angiography showed multiple stenoses of the right renal artery. Although renal artery stenosis in Moyamoya disease has been effectively treated with balloon angioplasty, stent implantation, or surgery, bat-loon angioplasty could not be done in this patient due to multiple stenoses. His blood pressure was successfully controlled with medical treatment, and remained normotensive during the follow up period of 6 months.

  • PDF

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Treatment of Subclavian Artery Injury in Multiple Trauma Patients by Using an Endovascular Approach: Two Cases (다발성 외상환자에서 혈관계 접근을 통해 치료한 쇄골하동맥 손상 2례)

  • Cho, Jayun;Jung, Heekyung;Kim, Hyung-Kee;Lim, Kyoung Hoon;Park, Jinyoung;Huh, Seung
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.243-247
    • /
    • 2013
  • Introduction: Surgical treatment of subclavian artery (SA) injury is challenging because approaching the lesion directly and clamping the proximal artery is difficult. This can be overcome by using an endovascular technique. Case 1: A 37-year-old male was drawn into the concrete mixer truck. He had a right SA injury with multiple traumatic injuries: an open fracture of the right leg with posterior tibial artery (PTA) injury, a right hemothorax, and fractures of the clavicle, scapula, ribs, cervical spine and nasal bone. The injury severity score (ISS) was 27. Computed tomography (CT) showed a 30-mm-length thrombotic occlusion in the right SA, which was 15 mm distal to the vertebral artery (VA). A self-expandable stent($8mm{\times}40mm$ in size) was deployed through the right femoral artery while preserving VA flow, and the radial pulse was palpable after deployment. Other operations were performed sequentially. He had a viable right arm during a 13-month follow-up period. Case 2: A 25-year-old male was admitted to our hospital due to a motorcycle accident. The ISS was 34 because of a hemothorax and open fractures of the mandible and the left hand. Intraoperative angiography was done through a right femoral artery puncture. Contrast extravasation of the SA was detected just outside the left rib cage. After balloon catheter had been inflated just proximal to the bleeding site, direct surgical exploration was performed through infraclavicular skin incision. The transected SA was identified, and an interposition graft was performed using a saphenous vein graft. Other operations were performed sequentially. He had a viable left arm during a 15-month follow-up period. Conclusion: The challenge of repairing an SA injury can be overcome by using an endovascular approach.

Long-term Clinical Outcomes after Primary Percutaneous Coronary Intervention in Patients with Acute Myocardial Infarction-on the basis of 65 Years (급성 심근경색증 환자에서 일차적 관상동맥 중재술 후 장기적 임상 경과-65세를 기준으로)

  • Lee, Han-Ol;Jang, Seong-Joo;Kim, In-Soo;Han, Jae-Bok;Park, Soo-Hwan;Kim, Jeong-Hun;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.251-261
    • /
    • 2014
  • Primary percutaneous coronary intervention (PCI) has been found to be superior, in terms of hospital mortality and long-term outcome, compared with thrombolytic therapy in patients with acute myocardial infarction (AMI). However, the clinical benefits of primary PCI have not been precisely evaluated in elderly patients.1,974 patients (Group I: n=1,018, $age{\geq}65years$, $73.8{\pm}5.99years$; Group II: n=956, age<65years, $52.8{\pm}7.96years$) who underwent primary PCI for AMI at Chonnam National University Hospital between 2006 and 2010 were analyzed according to their clinical, angiographic characteristics for hospital and one-year survival. Group I had a higher percentage of women, diabetes mellitus, hypertension, multi-vessel disease and lower prevalence of current smoking, hyperlipidemia, familial history than Group II. Culprit lesions were at the left anterior descending artery, left circumflex artery, right coronary artery and left main artery in 42.8% vs. 45.0%, 34.1% vs. 29.6%, 14.6% vs 14.6, 2.7% vs. 1.6%, respectively (p=0.007). Stent diameter was smaller in group I ($3.17{\pm}0.39$ vs. $3.29{\pm}0.42mm$, p=0.001). In-hospital mortality was higher in group I (8.4 vs. 1.9%, p<0.001). There were significant differences in the rates of major adverse cardiac events between the two groups during one-year clinical follow-up (20.1 vs.14.0%, p<0.001). On multiple logistic regression analysis, systolic blood pressure<100mmHg, serum $creatinine{\geq}1.3mg/dL$, Killip class> I, multivessel disease, left ventricular ejection fraction <40% and cerebro vascular disease were independent predictors of one-year motality in patients over 65 years after PCI.