• Title/Summary/Keyword: varnish

Search Result 198, Processing Time 0.029 seconds

Conservation and Restoration of Bamboo Brush Stand with Carved Design (죽제조문필통(竹製彫文筆筒)의 보존과 복원)

  • Son, Jongmin;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.10
    • /
    • pp.21-27
    • /
    • 2009
  • This bamboo brush stand was made by attaching two bamboo tubes together, each 80mm in diameter. On the bottom is a "∞-shaped"wood board made of Ailanthus altissima. The surfaces are decorated with exquisite and dynamic designs of a dragon and clouds, and a deer and pine trees. Part of this bamboo brush stand was damaged, lost, or worn down, prior to conservation treatment. After conservation and recovery treatment, its original form was restored. Earth powder, chalk, and gluten mixture were used as materials to fill in the missing parts. After the original form was restored, thin silk fabric was attached to the inner surface of the glued part to prevent cracking. Traditional materials and repair techniques were used to allow for reversal of treatment, if necessary, as seen in the surface of the restored part being made antiquated with lacquer varnish.

A COMPARATIVE STUDY ON THE APICAL LEAKAGE OF VARIOUS RETROFILLING MATERIALS (Retrofilling시 수종충전재료의 변연누출에 관한 연구)

  • Ohn, Yeong-Suck;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.118-125
    • /
    • 1991
  • Eighty - eight recently extracted teeth were used to evaluate the leakage characteristics of the following retrofilling materials; amalgam, zinc oxide eugenol cement, glass - ionomer cement, and cermet glass - ionomer cement. Root canals were prepared with step - back method and obturated with gutta percha and zinc oxide eugenol sealer. Root apex were resected 2 mm from apex and class I cavities were prepared with 2 mm or 4 mm depth. The cavities were filled with above materials. After application of varnish on all surface except resected surface, the roots were placed in 1 % methylene blue solution for 6 days. After longitudinal polishing to expose cental parts of filled materials, penetrated depths of dye were measured. The results were as follws. 1. As retrofilling material, glass ionomer cement filling groups showed less leakage than the other groups except zinc oxide eugenol cement filling group(p<0.01). 2. Amalgam filling groups had greater leakage than zinc oxide eugenol cement filling group(p<0.01). 3. 4 mm depth of retrofilled cavity had no effect on leakage characteristics compared with 2 mm depth cavity(p>0.05). 4. Glass ionomer cement and cermet glass ionomer cement filling groups showed less apical leakage than amalgam filling groups. But there was no statistical significance(p>0.05). 5. There was no difference in apical leakage between glass ionomer cement filling groups and cermet glass ionomer cement filling groups(p>0.05).

  • PDF

Enhancement of Dielectric Properties of Polyamide Enamel Insulation in High Voltage Apparatuses Used in Medical Electronics by Adding Nano Composites of SiO2 and Al2O3 Fillers

  • Biju, A.C.;Victoire, T. Aruldoss Albert;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1712-1719
    • /
    • 2015
  • In recent days, there was a significant development on the electrical, thermal, mechanical, physical, chemical, magnetic and optical properties of the polyamide enamel, varnish and other insulating materials by the addition of nano fillers to it. Enamel was used in High Voltage Apparatuses used in Medical Electronics as insulation. Insulating materials determine the life time of the electrical apparatuses. The life time of the insulating materials was improved by the addition of nano fillers to it. Hence the life time of the electrical apparatuses was improved by the mixing of nano fillers to the enamel. In this research, the basic dielectric properties of the enamel and enamel mixed with nano composites of silica and alumina were analyzed and compared with each other. The addition of nano fillers has improved the quality factor and capacitance of the enamel. It was also observed that the addition of nano fillers has reduced the dissipation factor and dielectric losses of the enamel. Heat produced by the dielectric losses was also reduced by adding nano fillers to it.

VPI Varnishing Technology Effects on Frequency Characteristics of an Air Core Inductor Used in LISN Circuit Application

  • Kanzi, Khalil;Kanzi, Majid;Nafissi, Hamidreza
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 2013
  • The functional characteristic of LISN circuit, which is used for measurements of conductive noise in mains power line, is basically related to frequency characteristics of passive elements like inductors used in the circuit as well as the frequency response of inductors is highly related to the resins used in the varnishing process. The significant problem in determination of an inductor's frequency characteristic is the intrinsic resistance, inductance and parasitic capacitance. In this triplet, the parasitic capacitance is the major limiting factor of inductor's frequency range. This capacitance depends on inductor design parameters and materials filling the spaces of coil like resin and its coherency after curing process. In this paper, two similar inductors were designed and built. The first inductor was not varnished while the second one was varnished with VPI technology. VPI, or Vacuum, Pressure, Impregnation technology is one of the most reliable methods performing good insulating conditions for electrical circuits and windings based on resins. The measured results show that implying varnishing technology does not significantly affect the frequency response. However, due to mechanical solidity aspects and improved environmental protection, it is better to varnish the inductors.

The Insulation Test of Varnish (바니쉬의 절연성 평가)

  • Kim, Jeong-Hun;Shin, Beak-Chul;Kim, Sung-Pil;Lee, Soo-Woon;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.950-952
    • /
    • 1999
  • In this paper, we are studied a electrical properties study with P.D.GEORGE/STER LING Co. P.B 302-LV-2 POLYBUTADIENE RESIN which is used for VPI(Vacuum Pressure Impregnation)processing of field magnet and armature of traction motor in Korean national railroad at present was carried out its FT-IR (Fourier Transform Infra-Red) volume resistivity characteristics. The varnishes were experimented with the temperature range form $25[^{\circ}C]$ to $180[^{\circ}C]$ and applied voltage were supplied at 100, 250, 500, 1,000[V]. In this condition, the volume resistivity for specimens were measured. From the above study, the following data obtained for volume resistivity. It can be confirmed that velume resistivity with the increase of temperature is lower rapidly from room temperature to $130[^{\circ}C]$, and it is lower slowly at temperature higher than $130[^{\circ}C]$. Volume resistivity value is higher, according as the specimen is thick gradually. As the applied voltage is higher in the same temperature, volume resistivity value is lower.

  • PDF

STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS (DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구)

  • Kown, O-Teak;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

The Analysis of 1,4-Dioxane in Water Sample by Gas Chromatograph/Mass Spectrometer and Risk Assessment (기체크로마토그래프/질량분석계에 의한 물시료 중 1,4-dioxane의 분석 및 위해성 평가)

  • 홍지은;표희수;박송자
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.3
    • /
    • pp.219-224
    • /
    • 2003
  • 1,4-Dioxane is used as a solvent for lacquers, paints, varnish removers, dye baths and printing compositions. And it is also used for detergent preparations, cosmetics, deodorants and fumigants. A method is described for the determination of 1,4-dioxane in water samples by GC/MS. The extraction recoveries were studied for some solvents and solvent volume ratio were investigated using r-butyl methyl ether (MTBE). Optimum condition was obtained by the liquid-liquid extraction using the 10 mL of MTBE for 10 mL of water. Method detection limit of 1,4-dioxane in the 20 mL of water samples was 0.05 ng/mL. It could be determined in the range of 0.24∼240 ng/mL in treated water, and in the range of 0.69∼81.9 ng/mL in raw water, respectively. Risk assessments with 1,4-dioxane exposure by drinking water ingestion were carried out. Based on the results of analysis, chronic daily intake of 1,4-dioxane was 2.22${\times}$10$\^$-4/ mg/kg/day and excess cancer risk was calcu-lated to be 2.44${\times}$10$\^$-6/.

A STUDY OF SHEAR STRESS AND FRACTURE PATTERN OF VARIOUS DENTIN BONDING RESTORATIVE MATERIALS (수종 상아질접합 수복재의 전단응력 및 파절형태에 관한 연구)

  • Shin, Dong-Hoon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.95-105
    • /
    • 1986
  • For the purpose of obtaining a basic data in selecting a suitable material with clinical care, this study was designed to measure the shear stress and to examine the fracture pattern of various dentin bonding restorative materials using 43 extracted bicuspids. The following results were obtained. 1. In dentin, Silux/Scotchbond group showed the highest value ($34.5{\pm}14.7kg/cm^2$) and Fuji Ionomer Type II group and Heliosit/Dentin-Adhesit group showed almost same bond strength in the next place. Durafill/Dentin-Adhesive group showed an infinitesimal value. ($3.1{\pm}1.4kg/cm^2$) 2. Every group showed no difference in bond strength between upper and lower teeth. Between buccal and lingual surfaces. Fuji Ionomer Type II and Durafill/Dentin-Adhesive groups showed too. But, in Silux/Scotchbond and Heliosit/Dentin-Adhesit groups, it was shown that the bond strength in lingual was stronger than in buccal. 3. There was resin fracture with cohesive fracture of bonding agent in Enamel group. In dentin, adhesive-cohesive fracture and adhesive fracture were shown. 4. The stronger bond strength was, the more frequently cohesive fracture occurred. Dentin-Adhesit group showed specific shining appearance as if varnish became hard.

  • PDF

A STUDY ON THE GALVANIC CURRENT BETWEEN GOLD AND AMALGAM (아말감과 금합금의 Galvanic 전류 측정에 관한 실험적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1984
  • It was the purpose of this study to determine the galvanic current between a gold alloy inlay and four types of amalgam using the circuit through pulp chambers when the freshly extracted teeth with those restorations were brought into contact in a physiologic saline solution, and to investigate the effectiveness of cavity varnish or ammonated silver-nitrate on the surface of amalgam restoration in reducing galvanic current. The current was measured with current-to-voltage converter and recored on a physiograph 6630-257. The following results were obtained. 1. Generally, galvanic current decreased as the time elapsed. 2. Galvainc current decreased significantly in the first day and after then minimal change was observed until 30th day. 3. Initial galvanic current was 29.6 ${\mu}A$ in the cut amalgam and 24.5 ${\mu}A$ in Dispersalloy amalgam and after then the current was significantly decreased. 4. Initial galvanic current was 12.6 ${\mu}A$ in spherical amalgam (low copper amalgam) and 13.8 ${\mu}A$ in Tytin amalgam and the amount of change was lower in sperical amalgam and Tytin amalgam than that in lathe cut amalgam and Dispersalloy amalgam. 5. Painting ammoniated silver-nitrate or Copalite on the surface of amalgam resotration decreased initial galvanic current and ammoniated silver-nitrate is more effective in decreasing galvanic current than Copalite. 6. Galvanic current by contact between amalgam restoration and gold restoration increased abruptly and dropped rapidly becoming almost.

  • PDF

Design of Class E Insulation Induction Motor (E종 절연 유도 전동기의 설계)

  • Sung Won Lee
    • 전기의세계
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 1967
  • From the discovery of Alago's disk, a number of trials and efforts have been concentrated on a small-sized and light-weighted induction motor. They have devoted themseleves, however, mainly to a improvement of cooling effect, a proper weight-distribution of copper and iron and desirable number of slots. In consequence, such an effort restricted only to the field of design, has resulted in unsatisfactory developments in the insulating materials consisting of the main parts of an induction motor. The quality of fibre and paper which are used as class-A insulation materials with their "compound" and "varnish" has been increased to some extent. Similarly Class-B insulation materials like asbest mica has been almost a combination of inorganic and binding materials. But nowadays synthesic chemistry is making a remarkable progress. So it comes possible for us to have silicon resin and other good ones of similar charateristics. And even a thin silicon resin insures us to get excellent heat-pro f and insulation, so a better space factor and cost-down in motor design have come possible in most advanced nations of the world, but not in our country. Furthermore, a consideration of productivity and economy in manufacturing process has been neglected by a majority of engineers. This is more unpleasant und more undesirable. I think this rational method of induction motor design using new synthesic resin will devote in making your productivity and economy better. And the nation-wide standard value of electric motor size is sited here. size is sited here.

  • PDF