• Title/Summary/Keyword: varied-intensity

Search Result 398, Processing Time 0.029 seconds

Physiological Responses to Different Exercise Intensities while Wearing Different Types of Sportswear Materials (스포츠웨어 착용에 따른 운동시 온열생리반응에 미치는 영향)

  • Kim, Tae-Gyou;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.8 no.1
    • /
    • pp.123-128
    • /
    • 2006
  • For the purpose of examining the relationship of physiological and subjective responses to different exercise intensities and varied types of sportswear material, under environmental condition $20{\pm}1^{\circ}C$ $50{\pm}3%$RH, five men who wear four different kinds of sportswear which have same clothing cover area. The subjects exercised for 20 min with a 20 min pre-exercise rest period and another 20 min post-exercise recovery period. Throughout the 60 min. duration, we monitored the local skin temperature, rectal temperature, clothing microclimate and subjective sensation. The mean skin temperature was recorded to range from $33.5{\sim}34.1^{\circ}C$ for the entire duration of the experiment with the highest temperature observed at the 7th min after starting the exercise. During the exercise intensity at THR 20, the lowest recorded temperature was at the 5th min of the recovery time and stabilized at the 10th min. However, in the exercise intensity condition at THR 70, the temperature declined steadily until the end of the experiment. With regard to clothing materials, cotton 100% and Polyester/Cotton blended fabrics knit(35/65) was $0.5{\sim}0.7^{\circ}C$ maintained lower than Polyester 100% and polyester/Cotton blended woven fabrics (65/35). In the case of the rectal temperature at THR 70 in case of PET 100%, Polyester/Cotton blended woven fabrics (35/65) was higher $0.2{\sim}0.5^{\circ}C$ than other sportswear throughout the duration of the experiment.

Effects of Modulation Type on Electrically-Elicited Tactile Sensation (전기자극 변조방식이 체성감각에 미치는 영향)

  • Hwang, Sun-Hee;Ara, Jawshan;Song, Tong-Jin;Bae, Tae-Sue;Park, Sang-Hyuk;Khang, Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.711-716
    • /
    • 2012
  • The purpose of this study was to investigate how the modulation method affects the effectiveness of eliciting tactile sensations by electrical stimulation. Two methods were employed and the results were compared and analyzed; pulse amplitude modulation (PAM) and pulse width modulation (PWM). Thirty-five healthy subjects participated in the experiments to measure the stimulation intensity that began to elicit a tactile sensation - activation threshold (AT). Constant-current monophasic rectangular pulse trains were employed, and the stimulation intensity was varied from zero until the subject felt any uncomfortable sensation. The step size of the stimulation intensity was 100nC/pulse. After each experiment, the subject described the sensation both quantitatively and qualitatively. The two modulation methods did not make a significant difference as far as the AT values were concerned, but most of the subjects showed 'intra-individual' consistency. Also, it was confirmed that our range of the stimulation parameters enabled us to obtain three major tactile sensations; tickling, pressure and vibration. The results suggested that the stimulation parameters and the modulation type should be selected for each individual and that selective electrical stimulation of the mechanoreceptors needs more diversified researches on the electrode design, multi-channel stimulation protocol, waveforms of the pulse train, etc.

Ultraviolet Inactivation of Escherichia coli in Stainless Steel Cups (스테인리스스틸 컵 내 Escherichia coli의 자외선 살균)

  • Mok, Chulkyoon;Lee, Nam-Hoon
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • Ultraviolet (UV) is widely used as a sterilizing agent in restaurants and catering facilities in Korea. Efficacy of UV sterilizers (UVS) was investigated against E. coli on the inner bottom of stainless steel cups. UV intensity on the bottom of cups varied widely with the locations of cups in UVS, showing higher values at center while lower values at outskirts. The deviations in UV intensity were remarkable on top shelf, but alleviated as proceeded to middle and bottom shelves. Inactivation of E. coli was proportional to the UV intensity and treatment time, consequently to UV dose, and showed a pseudo-first-order kinetics with tailing. Initial inactivation rate constants ($K_{1}$) deviated with the locations of the cups, while final inactivation rate constants ($K_{2}$) showed comparable values. An equation for the calculation of the proposed UV treatment time was suggested.

Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy (Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가)

  • Ham, Il-Sik;Cho, Pyong-Kon;Jung, Kang-Kyo
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.

Anomalous Luminescence and Emission Quenching Behaviors of Tris(2,2$^\prime$-bipyridine)Ruthenium(Ⅱ) in Poly(methacrylic acid) Solutions$^1$

  • Park, Joon-Woo;Paik, Young-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.137-142
    • /
    • 1986
  • The luminescence spectra of $Ru(bpy)_3^{2+}$ in poly(methacrylic acid) (PMA) solutions varied sensitively with pH. At pH < 5.5, the emission intensity increased with pH up to 4 times, while it decreased with pH beyond the pH. The enhanced emission intensity was accompanied by blue-shift of the emission maxima as much as 15 nm. The enhancement of emission intensity was attributed to the restricted rotational mobility of ligand of the cation bound to densely coiled PMA molecules at pH < 5.5. The sharp decrease in emission intensity with increasing pH near pH 5.6 was accounted for conformational transition of the polymer to more extended structure, which was also revealed in viscosity measurement. The enhancement of emission intensity became higher as NaCl concentration of the solution increased. The binding constant of $Ru(bpy)_3^{2+}$ with two carboxylate groups of PMA was calculated as $2{\times}10^5\;M^{-1}$ in 0.1 M NaCl at pH 5.2. The pH dependence of luminescence quenching rate of $Ru(bpy)_3^{2+}$ by $Cu^{++}$ also showed maximum near pH 5, and the rate was more than $10^3$ times higher than that in water, whereas the maximum enhancement of quenching rate (about 20 times) in poly(acrylic acid) (PAA) solution occurred at pH 4.5. On the other hand, the pH dependence for neutral water soluble nitrobenzene (NB) exhibited opposite trend to that of $Cu^{++}$. The quenching constant vs pH curve for $MV^{++}$ was composite of those for $Cu^{++}$ and NB. The anomalous high quenching rate for $Cu^{++}$ in PMA solution at pH < 5.5 was attributed to the binding of $Ru(bpy)_3^{2+}$ and $Cu^{++}$ to the same region of PMA, when it conforms densely coiled structure in the pH range. The observation of mininium quenching rate for NB near pH 5.5 indicated that the $Ru(bpy)_3^{2+}$ bound to the densely coiled PMA is not accessible by NB, which is in bulk water phase. The composite nature of the pH dependence of quenching rate for $MV^{++}$ in PMA solution was attributed to the smaller binding affinity of the cation to PMA, compared to that of $Cu^{++}$. The sharp, cooperative conformational transition with pH observed in PMA was not revealed in PAA. But, the pH dependence of quenching rates in this polymer reflected increased charge density and, thus, binding of cations to the polymer, and expansion of the polymer chain with pH.

Electrical Properties of Organic Photovoltaic Cell using CuPc/$C_{60}$ double layer (CuPc/$C_{60}$ 이중층을 이용한 유기 광기전 소자의 전기적 특성)

  • Lee, Dong-Shin;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.744-746
    • /
    • 2008
  • Organic photovoltaic effects were studied in a device structure of ITO/CuPc/Al and ITO/CuPc/$C_{60}$/BCP/Al. A thickness of CuPc layer was varied from 10 nm to 50 nm, we have obtained that the optimum CuPc layer thickness is around 40 nm from the analysis of the current density-voltage characteristics in CuPc single layer photovoltaic cell. From the thickness-dependent photovoltaic effects in CuPc/$Cu_{60}$ heterojunction devices, higher power conversion efficiency was obtained in ITO/20nm CuPc/40nm $C_{60}$/Al, which has a thickness ratio (CuPc:$C_{60}$) of 1:2 rather than 1:1 or 1:3. Light intensity on the device was measured by calibrated Si-photodiode and radiometer/photometer of International Light Inc(IL14004).

  • PDF

Synthetic Strategy and Optical Property Characterization of Complex Nanorods: Plasmon Wave Guide and Solar Cell

  • Park, Sung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.111-111
    • /
    • 2012
  • In this talk, we represent a novel approach to investigating intra-nanorod surface plasmon coupling with control over block compositions. The multi-component rod-like nanostructures, which consist of optically active components (Au and Ag) and optically less active component (for example, Ni) in UV-vis-NIR spectral window, showed interesting optical response depending on each block length and the total length of the structure. By controlling the composition and relative lengths of the blocks that comprise these structures, we can tailor the overall optical properties. Depending on the relative fraction of Au and Ag blocks, the intensity of the transverse modes varied without noticeable peak shifts. However, the strong intraparticle surface plasmon coupling resulted in the collective appearance of longitudinal LSP modes, including higher-order modes. The experimental observations were confirmed by theoretical calculation, using a discrete dipole approximation method. In addition, we will briefly discuss how single nanorod solar cells can be synthesized by using by using electrochemical deposition and AAO hard templates.

  • PDF

Experimental Study on the Effects of Upstream Periodic Wakes on Aerofoil-Boundary Layer and Loss (주기적 상류 후류의 익 경계층과 손실에 미치는 영향에 대한 실험적 연구)

  • Rim, In-Won;Cho, Kang-Rae;Joo, Won-Gu
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.661-667
    • /
    • 2001
  • This paper is concerned with the effects of periodically approaching upstream wakes on cascade-flow and loss. The reduced frequency of the periodic wakes was varied in the narrow range from 0.5 to 0.7. According to a wake-passing through the cascade, two velocity deficits appear near the boundary layer contour in the downstream from about 60% chord-length. The first velocity deficit is caused by a periodic wake and the second one appears after some delayed time. The second velocity deficit may be interpreted as the results of reattachment of flow-separation. The higher reduced frequency decreases the duration time of separation appearance and the lesser loss of aerofoil is resulted.

  • PDF

The Effects of Sintering Temperature of Organic Ag Complex on the Photoluminescence Characteristics of MEH-PPV (유기 은(Ag) 화합물의 소결 온도가 MEH-PPV의 PL특성에 미치는 영향)

  • Kang, Min-Ki;Moon, Dae-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.328-329
    • /
    • 2009
  • This paper presents the effect of organic Ag complex sintering temperature on the MEH-PPV photoluminescence (PL) properties. MEH-PPV and organic Ag complex was coated on the glass substrate by spin coating method. The coated Ag complex was sintered in an air atmosphere. The sintering temperature was varied from 100 to $200^{\circ}C$ and sintering time was 5 min. The Ag film sintered at temperature higher than $120^{\circ}C$ shows very low sheet resistance less than $0.5\;{\Omega}{/\square}$. The coated MEH-PPV measure photoluminescence (PL) intensity at 580 nm. The PL peak was shifted to the higher wavelength with increasing the sintering temperature.

  • PDF

Development of simulator for Computer-integrated Robotic Surgery system and Design of its Auto-illumination system (수술통합시스템 시뮬레이터 개발과 자동조명시스템의 설계)

  • Lee, Soo-Gang;Chung, Goo-Bong;Yi, Byung-Ju;Kim, Whee-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.456-458
    • /
    • 2004
  • Recent medical robot systems perform surgery operations, by following the preplanned trajectory and surgical procedures. Depending on the complexity of surgery operations, they are operated in manual, semi-automatic or full automatic mode. To improve the performance of those medical robot systems, development of the simulator and more advanced auto-illumination system, in which intensity of light, direction and focal point can be controlled automatically according to the varied environments during surgical operations. are required. Therefore, in this paper, the simulator for SPINEBOT system which is a computer-intergrated robotic surgery system are developed. And further, an auto-illumination system which will be integrated to the SPINEBOT system is investigated and its preliminary design is described.

  • PDF