The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Ecological Health Diagnosis of Sumjin River using Fish Model Metric, Physical Habitat Parameters, and Water Quality Characteristics (어류모델 메트릭, 물리적 서식지 변수 및 수질특성 분석에 의한 섬진강의 생태 건강성 진단)

  • Lee, Eui-Haeng;Choi, Ji-Woong;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.184-192
    • /
    • 2007
  • This study was to evaluate ecological health of Sumjin River during April${\sim}$June 2006. The ecological health assessments was based on the Index of Biological Integrity (IBI), Qualitative Babitat Evaluation Index (QHEI), and water chemistry. For the study, the models of IBI and QHEI were modified as 10 and 11 metric attributes, respectively. We also analyzed spatial patterns of chemical water quality over the period of $2002{\sim}2005$, using the water chemistry dataset, obtained from the Ministry of Environment, Korea. In Sumjin River, values of IBI averaged 33 (n= 12), which is judged as a "Fair${\sim}$Good" condition after the criteria of Barbour at al. (1999). There was a distinct spatial variation. Mean IBI score at Site 5 was estimated as 40, indicating a "Good" condition whereas, the mean at Site 3 was 23, indicating a "Poor${\sim}$Fair" condition. Habitat analysis showed that QHEI values in the river averaged 109 (n=6), indicating a "Marginal" condition after the criteria of Harbour et al. (1999). Values of BOD and COD averaged 1.3 mg $L^{-1}$ (scope: $0.9{\sim}1.8$ mg $L^{-1}$) and 3.3 mg $L^{-1}$ (scope: $2.8{\sim}4.0$ mg $L^{-1}$), respectively during the study. It was evident that chemical pollutions by organic matter were minor in the river. Total nitrogen (TN) and total phosphorus (TP) averaged 2.5 mg $L^{-1}$ and 0.067 mg $L^{-1}$, respectively, and the nutrients did not show large longitudinal gradients between the upper and lower reach. Overall, dataset of IBI, QHEI, and water chemistry suggest that river health has been well maintained, compared to other major watersheds in Korea and should be protected from habitat disturbance and chemical pollutions.

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

The Kinematical Analysis of Straddle Jump to Push up Motion on Sports Aerobics (스포츠 에어로빅스 Straddle Jump to Push up 동작의 운동학적 분석)

  • Kim, Cha-Nam
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.77-90
    • /
    • 2002
  • This study serves the purpose of understanding about correct jump and landing motion through Kinematical Analysis of Straddle Jump to Push up Motion at target by four elite sports aerobics athletes have more than four years career. And further more that make good assistance for coaches effective guidance through an offer basic data and correct diagnosis, evaluate of motions. It was picture-taked by two-video camera for Straddle Jump to Push up Motions. Camera speeds are 60 frame/sec. There are Kinematical Variation elements for analysis, the displacement of COG, each angle displacement left/right of shoulder-joint, each angle displacement left/right of knee-joint and each speed left/right of tip of the toes. Every each person accomplished severaly 3 times and we have acquired this conclusion. The conclusions were as follows; 1. Each situation for displacement of COG showed low height of COG by phase 1, 4, 5(79.05${\pm}9.07,\;46.41{\pm}3.65,\;18.66{\pm}0.54cm$) and It showed high height of COG by phase 2, 3($120.80{\pm}6.13,\;148.12{\pm}9.19cm$). 2. Each displacement left, right of shoulder-joint flexion by phase 1($91.07{\pm}8.30,\;90.77{\pm}5.72$deg/sec)and It showed maximal extension angles by phase 2($102.48{\pm}10.00,\;102.39{\pm}10.51$deg/sec). in part of phase 3, left of shoulder-joint angle($94.43{\pm}4.12$deg/sec) showed flexion phase 1, the other right shoulder-joint angle(88.38${\pm}$4.98deg/sec) showed more a little lower than phase 1, in last phase that showed most low by phase 4($70.58{\pm}13.72,\;54.24{\pm}11.58$deg/sec). 3. Each displacement left, right of hip joint showed maximal extent conditions by phase 2, 3($160.35{\pm}22.68,\;1534.77{\pm}5.40$deg/sec, $150.04{\pm}12.79,\;145.54{\pm}13.00$deg/sec) beside, ankle-joint showed minimal angle by phase 1, 4($93.59{\pm}18.92,\;85.37{\pm}13.23$deg/sec, $66.60{\pm}15.77,\;80.60{\pm}16.57$deg/sec). 4. Each displacement left, right of hip joint showed maximal extent conditions by phase 2($157.15{\pm}9.13,\;163.52{\pm}8.18$deg/sec), and right of hip joint showed minimal angle by phase 3($110.87{\pm}13.81,\;77.53{\pm}8.95$deg/sec) It showed alike condition of low angle by phase 1, 4($91.04{\pm}2.31,\;96.26{\pm}2.20$deg/sec). 5. Each displacement left, right of knee-joint showed maximal extent conditions by phase 1, 3, 4($173.46{\pm}2.95,\;171.51{\pm}5.44$deg/sec, $172.24{\pm}4.49,\;171.26{\pm}0.65$deg/sec, $162.78{\pm}2.13,\;164.10{\pm}5.97$deg/sec) but It showed flexion only left of knee-joint by phase 2($164.45{\pm}7.51,\;159.38{\pm}3.48$deg/sec). 6. Each speed left, right of the tip of the toes showed most fastest when someone jumped with lift up leges by phase 1, 2($321.32{\pm}67.91,\;316.90{\pm}41.97$cm/sec, $410.06{\pm}153.06,\;399.77{\pm}189.34$cm/sec), It showed more less speed than phase 1,2 by phase 3($169.74{\pm}67.17,\;150.00{\pm}63.80$cm/sec) and It showed most slow speed than phase 1,2,3 by phase 4($87.22{\pm}34.90,\;85.72{\pm}52.23$cm/sec).

A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.