• Title/Summary/Keyword: variance to mean ratio

Search Result 156, Processing Time 0.03 seconds

Development of Diameter Growth Models by Thinning Intensity of Planted Quercus glauca Thunb. Stands

  • Jung, Su Young;Lee, Kwang Soo;Kim, Hyun Soo
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.6
    • /
    • pp.629-638
    • /
    • 2021
  • Background and objective: This study was conducted to develop diameter growth models for thinned Quercus glauca Thunb. (QGT) stands to inform production goals for treatment and provide the information necessary for the systematic management of this stands. Methods: This study was conducted on QGT stands, of which initial thinning was completed in 2013 to develop a treatment system. To analyze the tree growth and trait response for each thinning treatment, forestry surveys were conducted in 2014 and 2021, and a one-way analysis of variance (ANOVA) was executed. In addition, non-linear least squares regression of the PROC NLIN procedure was used to develop an optimal diameter growth model. Results: Based on growth and trait analyses, the height and height-to-diameter (H/D) ratio were not different according to treatment plot (p > .05). For the diameter of basal height (DBH), the heavy thinning (HT) treatment plot was significantly larger than the control plot (p < .05). As a result of the development of diameter growth models by treatment plot, the mean squared error (MSE) of the Gompertz polymorphic equation (control: 2.2381, light thinning: 0.8478, and heavy thinning: 0.8679) was the lowest in all treatment plots, and the Shapiro-Wilk statistic was found to follow a normal distribution (p > .95), so it was selected as an equation fit for the diameter growth model. Conclusion: The findings of this study provide basic data for the systematic management of Quercus glauca Thunb. stands. It is necessary to construct permanent sample plots (PSP) that consider stand status, location conditions, and climatic environments.

Food sources of zinc and nutritional status with usual dietary zinc intake in Korean toddlers and preschool children

  • SuJin Song;Jae Eun Shim
    • Nutrition Research and Practice
    • /
    • v.17 no.6
    • /
    • pp.1211-1224
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: This study aimed to evaluate the food sources of zinc and the usual intake of dietary zinc among Korean toddlers and preschool children. SUBJECTS/METHODS: A total of 2,679 children aged 1-5 years was selected from the 2009-2013 Korea National Health and Nutrition Examination Survey (KNHANES) data. Dietary data collected from a single 24-h recall were used to evaluate the food sources of zinc. To estimate usual zinc intake, the distribution obtained from single 24-h recall data in the total sample was adjusted using the ratio of within-to-between-person variance in zinc intake obtained from 2-day 24-h recall sub-sample data of the 2009 KNHANES. The proportion of children with usual zinc intake below the estimated average requirement (EAR) and above the tolerable upper intake level (UL) was assessed. RESULTS: The main sources of zinc in Korean children were grains, dairy products, and meat. The mean usual intakes of zinc among all individuals, those aged 1-2 yrs, and those aged 3-5 yrs were 5.50, 5.01, and 5.83 mg/d, respectively. In all participants, 1.1% of the children consumed zinc below the EAR, whereas 10.7% exceeded the UL. The proportion of children with excessive zinc intake was 25.6% in the 1-2 yrs age group and 0.6% in the 3-5 yrs age group. CONCLUSIONS: According to the current UL, the risk of excessive zinc intake appears to be high among Korean toddlers. Future studies that monitor the health effects of excessive zinc intake are needed to appropriately guide zinc intake in children.

Pharmacokinetic Properties and Bioequivalence of Cefcapene Pivoxil Hydrochloride 75 mg in Korean Healthy Volunteers (건강한 한국인 피험자에서 Cefcapene Pivoxil Hydrochloride 75 mg 제제의 생물학적동등성시험)

  • Jeon, Ji-Young;Im, Yong-Jin;Hwang, Min-Ho;Kim, Yun-Jeong;Han, Su-Mi;Jo, Myeong-Jin;Kim, Hee-Sun;Kim, Sun-Young;Chae, Soo-Wan;Kim, Kang-Seog;Kim, Min-Gul
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.1
    • /
    • pp.9-12
    • /
    • 2012
  • Background: Cefcapene pivoxil hydrochloride, is an ester-type oral cephem antibiotic. This study was performed to compare the pharmacokinetics and evaluate the bioequivalence of two cefcapene pivoxil hydrochloride 75 mg formulations. Method: In a randomized $2{\times}2$ crossover study, sixty healthy male volunteers were randomly assigned into two groups. After a single dose of 75 mg cefcapene pivoxil hydrochloride oral administration, blood samples were collected at specific time intervals from 0-12 hours. The plasma concentrations of cefcapene pivoxil hydrochloride were determined by LC-MS/MS. The pharmacokinetic parameters were determined from the plasma concentration-time profiles of both formulations. The pharmacokinetic parameters such as $AUC_{last}$, $AUC_{inf}$ and $C_{max}$, were calculated and the 90% confidence intervals for test/reference ratio for pharmacokinetic parameters were obtained by analysis of variance on logarithmically transformed data. Results: The mean value for $AUC_{last}$ in test and reference drug was $4053.1{\pm}876.5\;ng{\cdot}hr/mL$ and $3595.7{\pm}1029.1\;ng{\cdot}h/mL$, respectively. The mean value for $C_{max}$ in test and reference drug was $1324.9{\pm}321.4$ ng/mL and $1159.1{\pm}335.9$ ng/mL, respectively. The 90% confidence intervals of the $AUC_{last}$ and $C_{max}$ ratio for test drug and reference drug were log 1.09-log1.22 and log 1.09-log1.24, respectively. No adverse events were reported by subjects or found on analysis of vital signs or laboratory tests. Conclusion: This single dose study found that the test and reference products met the regulatory criteria for bioequivalence in these health volunteers. Both formulations were safe and well tolerated in 75 mg of cefcapene pivoxil hydrochloride.

Comparing validity of using Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Risk Factors of Middle Aged Koreans (한국중년층에서 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 심장혈관계질환 위험인자 타당도 비교)

  • Mun, Hyeon-Gyeong;Kim, Yu-Jin
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.3
    • /
    • pp.365-374
    • /
    • 2005
  • This study was conducted to compare the validity of obese index among body mass index(BMI), waist to hip ratio(WHR), and waist circumference(WC) and to determine which is the best in relation to cardiovascular risk factors of middle aged Korean(40-64yr).Data from the 1998 Korean Health and Nutrition Survey were used(N=3380). Anthropometric indices and cardiovascular risk factors were measured. Chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator characteristic(ROC) curves were used in the analysis. There was a significant increasing trend in WHR, systolic blood pressure(SBP), high density lipoprotein cholesterol(HDL), and fasting blood sugar(FBS) with age categories of male and in BMI, WC, WHR, diastolic blood pressure(DBP), SBP, total cholesterol(TC), low density lipoprotein cholesterol(LDL), triglycerol(TG), and FBS with those of female. Specially female had the characteristics of upper body fat and systolic blood pressure risk(p<0.05). Proportions of subjects with lifestyle factors related to cardiovascular risk in overweight or upper body fat group were higher than that of normal group. Higher proportions of subjects were practiced exercise in upper body fat group of male than in other groups. Among 7 cardiovascular risk factors in partial correlation analysis, BMI had the highest correlation coefficient in 6 risk factors in male, whereas WC in 4 risk factors in female. Mean of each obese index according to cardiovascular risk groups except smoker was higher than that of normal(p<0.05). These trends were shown in upper body fat group and female. In ROC analysis of 12 risk factors and health conditions, the largest area under curve among obese indices for risk factors were BMI in male and WHR in female. The optimal cutoff values of each index(BMI: WHR: WC) for one or more cardiovascular risk factors were 23.13: 0.89: 85.35 in male and 23.57: 0.84: 78.35 in female. The results showed that cardiovascular risk factors were prevalent in middle aged Koreans within normal limits of obese indices like another Asians. For the identification of cardiovascular risk factors of middle aged Koreans, BMI for men and WHR for women are appropriate indices. But it is recommended that BMI, WHR, and WC, all three indices should be considered, when using these indices.

  • PDF

Usual intake of dietary isoflavone and its major food sources in Koreans: Korea National Health and Nutrition Examination Survey 2016-2018 data

  • Kim, Yoona;Kim, Dong Woo;Kim, Kijoon;Choe, Jeong-Sook;Lee, Hae-Jeung
    • Nutrition Research and Practice
    • /
    • v.16 no.sup1
    • /
    • pp.134-146
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: Accumulating evidence has shown the beneficial effects of isoflavone on health. There is limited information on the usual isoflavone intake for Koreans. This study examined the usual intake of total isoflavone and its major food sources in Koreans according to age and gender. SUBJECTS/METHODS: The dietary intake data of 21,271 participants aged 1 yrs and older from the Korea National Health and Nutrition Examination Survey (KNHANES) VII 2016-2018 were analyzed. The average isoflavone intake was estimated based on the 24-h dietary recall data in KNHANES and the isoflavone database from the Korea Rural Development Administration (RDA) and literatures. The usual isoflavone intake was estimated by applying the ratio of within- and between-participant variance estimated from the 2009 KNHANES data to the 7th KNHANES (2016-2018) data. The variance of the isoflavone intake was calculated using MIXTRAN macro with intake data for two days in the 2009 KNHANES. Complex sample analysis with stratified variables and integrated weights was conducted. RESULTS: The mean total isoflavone intake in the Korean population aged 1 yrs and older (n = 21,271) was 139.27 mg/d, which was higher than the usual intake of 47.44mg/d. Legumes were a major contributing food group (91%), with arrowroot being a major individual contributor to the isoflavone intake (67.2%), followed by 21.3% of soybean, 5.4% of bean sprouts, and 2.1% of tofu. The usual isoflavone intake was highest in the participants aged 50 to 64 yrs old and increased with age until 50 to 64 yrs and then decreased with further increases in age. The usual isoflavone intake of participants aged 65 yrs and older was higher for men than for women, showing gender differences. CONCLUSIONS: The usual dietary intake of isoflavone varied according to age and gender in the Korean population. This study showed that the usual isoflavone intake was lower than the average isoflavone intake. The difference between percentiles of the usual isoflavone intake was similarly smaller than the average intake. An estimation of average intake can be hindered by the occasional consumption of foods high in isoflavones, suggesting that the usual intake estimation method can be more appropriate. Further research will be needed to establish isoflavone dietary guidelines regarding the effects of isoflavone intake on health outcomes.

A Novel Water Surface Detection Method Based on Correlation Analysis for Rectangular Control Area (직사각형 검사영역의 상관도 분석을 통한 수면위치 탐색 방법)

  • Lee, Chan Joo;Seo, Myoung Bae;Kim, Dong Gu;Kwon, Sung Il
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1227-1241
    • /
    • 2012
  • In this study, a novel water surface detection method was proposed. In the method water surface is detected by analysis on correlation coefficients obtained from rectangular control areas of the same vertical position in two successive images including both water surface and staff gauge. Four methods respectively based on threshold, peak, slope and variance ratio, are used to identify water surface from vertical distribution of correlation coefficient. In addition, swaying correction algorithm and statistical filtering are applied to minimize outliers caused by positional image mismatch. Images taken from 28 different sites during low flow were tested to evaluate the method. Mean relative error to eye measurement was approximately from 3.4 to 5.7 cm. As long as water surface moves, this method can be used to improve image stage gauge by supplementing the previous water surface detection method.

Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

  • Shirali, Gholamabbas;Shekari, Mohammad;Angali, Kambiz Ahmadi
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.296-307
    • /
    • 2018
  • Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

An Adaptive Gradient-Projection Image Restoration using Spatial Local Constraints and Estimated Noise (국부 공간 제약 정보 및 예측 노이즈 특성을 이용한 적응 Gradient-Projection 영상 복원 방식)

  • Hong, Min-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10C
    • /
    • pp.975-981
    • /
    • 2007
  • In this paper, we propose a spatially adaptive image restoration algorithm using local and statistics and estimated noise. The ratio of local mean, variance, and maximum values with different window size is used to constrain the solution space, and these parameters are computed at each iteration step using partially restored image. In addition, the additive noise estimated from partially restored image and the local constraints are used to determine a parameter for controlling the degree of local smoothness on the solution. The resulting iterative algorithm exhibits increased convergence speed when compared to the non-adaptive algorithm. In addition, a smooth solution with a controlled degree of smoothness is obtained without a prior knowledge about the noise. Experimental results demonstrate that the proposed algorithm requires the similar iteration number to converge, but there is the improvement of SNR more than 0.2 dB comparing to the previous approach.