• 제목/요약/키워드: variable frequency control

검색결과 532건 처리시간 0.027초

Sliding mode control for structures based on the frequency content of the earthquake loading

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • 제5권3호
    • /
    • pp.209-221
    • /
    • 2009
  • A control algorithm for seismic protection of building structures based on the theory of variable structural control or sliding mode control is presented. The paper focus in the design of sliding surface. A method for determining the sliding surface by pole assignment algorithm where the poles of the system in the sliding surface are obtained on-line, based on the frequency content of the incoming earthquake signal applied to the structure, is proposed. The proposed algorithm consists of the following steps: (i) On-line FFT process is applied to the incoming part of the signal and its frequency content is recognized. (ii) A transformation of the frequency content to the complex plane is performed and the desired location of poles of the controlled structure on the sliding surface is estimated. (iii) Based on the estimated poles the sliding surface is obtained. (iv) Then, the control force which will drive the response trajectory into the estimated sliding surface and force it to stay there all the subsequent time is obtained using Lyapunov stability theory. The above steps are repeated continuously for the entire duration of the incoming earthquake. The potential applications and the effectiveness of the improved control algorithm are demonstrated by numerical examples. The simulation results indicate that the response of a structure is reduced significantly compared to the response of the uncontrolled structure, while the required control demand is achievable.

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

비자성 부하 유도 가열용 Half-Bridge Inverter의 효율 향상에 대한 연구 (A High Efficient Half-Bridge Inverter for Induction-Heating Applications with Non-Magnetic Load)

  • 정진우;이병국;서범석;현동석;정윤철;박병욱;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.303-305
    • /
    • 1996
  • A strategy that can maximize the efficiency of the inverter system for the non-magnetic material is proposed. Frequency control and variable DC-Link voltage control are compared and analyzed by the experimental results. The experimental results show the variable DC-Link voltage control is superior to the frequency control with respect to improve the efficiency of the inverter system. MOSFETs and IGBTs are used as switching devices and IGBTs are considerable as better switching devices for improving the efficiency of the inverter system.

  • PDF

MR유체를 이용한 엔진마운트의 슬라이딩모드제어 (A Sliding Mode Control for an Engine Mount Using Magneto-Rheological Fluid)

  • 이동길;안영공;정석권;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1144-1149
    • /
    • 2001
  • In this paper, a sliding mode controller of a fluid engine mount using MR (Magneto-Rheological) fluid was discussed When the MR fluid is applied to a fluid mount, resistance of MR fluid can be controlled by electro-magnetic valve installed in the inertia track. Since the rheological property of the MR fluid shows a function of shear rate, the damping characteristics of the mount will be change according to the frequency. Changing an applied magnetic field to the valve changes the property of the mount, such as the resistance of the MR fluid, the notch and the resonant frequencies due to the fluid passing, quantity of the fluid passing, the effective piston area of the volumetric damping and stiffness. Therefore, the fluid mount using MR fluid can be regarded as a variable structure system The sliding mode control known well as a particular type of variable structure control was introduced in this study. The sliding mode control, which has inherent robustness, is also expected to improve the control performance in the engine mount The sliding mode controller for the mount formatted by taking into account the response property with a time constant to MR fluid and the variable mount property. The motion equations of the fluid mount are derived from Newton's law of motion and used in numerical simulation. Numerical simulations illustrate the effectiveness of the sliding mode controller.

  • PDF

제어이론을 이용한 D급 디지털 오디오 증폭기의 모델링과 해석 (Modeling and Analysis of Class D Audio Amplifiers using Control Theories)

  • 류태하;류지열;도태용
    • 제어로봇시스템학회논문지
    • /
    • 제13권4호
    • /
    • pp.385-391
    • /
    • 2007
  • A class D digital audio amplifier with small size, low cost, and high quality is positively necessary in the multimedia era. Since the digital audio amplifier is based on the PWM signal processing, it is improper to analyze the principle of signal generation using linear system theories. In this paper, a class D digital audio amplifier based ADSM (Advanced Delta-Sigma Modulation) is considered. We first model the digital audio amplifier and then explain the operation principle using variable structure control algorithm. Moreover, the ripple signal generated by the hysteresis in the comparator has a significant effect on the system performance. Thus, we present a method to find the magnitude and the frequency of the ripple signal using describing function. Finally, simulations and experiments are provided to show the validity of the proposed methods.

가변구조 제어계의 채터링 현상의 제거 및 연속입력을 얻기 위한 입력법칙의 개선 (An Improvement of Continuous Control Law for Removing Chattering Phenomenon of VSC Systems)

  • 김중완;이만형
    • 대한전기학회논문지
    • /
    • 제38권1호
    • /
    • pp.60-67
    • /
    • 1989
  • In this paper, a methodology is developed to remove the high frequency chattering phenomenon which is the common drawbacks of variable structure control(VSC) system. An improved control law is proposed to achieve continuous control input whose terms are continuous functions during the control process under switching plane, which removes chattering and is robust as well. The methodology developed in this paper is applied to attitude control for spacecraft and the simulated results are compared with those of typical VSC methodology.

  • PDF

주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube with the Variation of Frequency)

  • Lee, Jong-Chan;Park, Dae-Hee
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF

계절성과 경향성을 고려한 극치수문자료의 비정상성 빈도해석 (Nonstationary Frequency Analysis of Hydrologic Extreme Variables Considering of Seasonality and Trend)

  • 이정주;권현한;문영일
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.581-585
    • /
    • 2010
  • This study introduced a Bayesian based frequency analysis in which the statistical trend seasonal analysis for hydrologic extreme series is incorporated. The proposed model employed Gumbel and GEV extreme distribution to characterize extreme events and a fully coupled bayesian frequency model was finally utilized to estimate design rainfalls in Seoul. Posterior distributions of the model parameters in both trend and seasonal analysis were updated through Markov Chain Monte Carlo Simulation mainly utilizing Gibbs sampler. This study proposed a way to make use of nonstationary frequency model for dynamic risk analysis, and showed an increase of hydrologic risk with time varying probability density functions. In addition, full annual cycle of the design rainfall through seasonal model could be applied to annual control such as dam operation, flood control, irrigation water management, and so on. The proposed study showed advantage in assessing statistical significance of parameters associated with trend analysis through statistical inference utilizing derived posterior distributions.

  • PDF

산업용 냉각기의 압축기 회전수 변화에 따른 용량제어 특성 (The characteristics of capacity control using a variable speed compressor in an industrial cooler)

  • 백승문;문춘근;윤정인;정석권;김은필
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents the capacity-control characteristics in an industrial cooler with a variable speed compressor. The inverter-type compressor is controlled by the rotational speed of the operational frequency. This type of the compressor performs the wide range of load compared to the on-off type. When the load of the system reduces, the rotational speed will be reduced. Thus, the system leads to the less power consumption and extends the longer durability of the compressor. With the variable rotational speed of the compressor the cooling capacity of the cooler is about 1.6-3.6 kW and the capacity control is about 40-100%. The system showed the highest efficiency when the rotational speed is about 45-70 Hz. The results can be used as the basic design data to control an industrial cooler.

입력전압 가변 및 동작 모드 변화를 통해 넓은 출력전압 범위에서 동작하는 LLC 공진컨버터 (LLC Resonant Converter Operating over a Wide Output Voltage Range by Varying the Input Voltage and Changing Operating Modes)

  • 이지철;주종성;허예창;마리우스;김은수;전용석;국윤상
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.517-526
    • /
    • 2017
  • In this paper, we propose an LLC resonant converter that operates over a wide controllable output voltage ($50V_{DC}$ to $800V_{DC}$) and shows high efficiency characteristics under all load conditions and output voltages. Two 3.3kW prototypes are designed for an experimental comparison between the variable frequency control (control scheme 1) and the variable input voltage($V_{IN}$) control (control scheme 2) mechanisms. The experimental results show that the variable input control mechanism demonstrates high efficiency under all loads and output voltages.