• Title/Summary/Keyword: variability of spectrum

Search Result 135, Processing Time 0.026 seconds

A development of measuring system for Autonomic Nervous Activity (자율신경계 활성도 측정 시스템 개발)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.141-146
    • /
    • 2000
  • Power spectrum analysis is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, We developed a measuring system for Autonomic Nervous Activity by using power spectrum analysis method to obtain the activities of autonomic nervous system. This system adopt a isolated power for patient's safety. In this system, Two output signal is obtained - R-R interval time variability and Respiration time variability. Time variability is use to find out some disease related to Autonomic Nervous System. Experimental tested range is 30 ~ 240 BPM for ECG and 15~80 BPM for Respiration.

  • PDF

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF

Elastic Resistance Exercise for the Elderly on the Magnitude of Frequency and Variability of Ground Reaction Force Signals during Walking (고령자 보행 시 탄성저항운동이 지면반력 신호의 주파수 크기와 variability에 미치는 영향)

  • Seo, Se-Mi;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.49-57
    • /
    • 2008
  • The purpose of this study was to determine the effects of 12-week elastic resistance exercise for the elderly on the magnitude of frequency and variability of ground reaction force signals. To this aim, total 12 elderly women aged in their 70 were participated in this study and asked to do a 12-week elastic resistance exercise program. FFT(fast Fourier Transform) was used to analyze the frequency domain analysis of the ground reaction forces's signals and an accumulative PSD (power spectrum density) normalized by support phase of walking was calculated to reconstruct the certain signals. To estimate the gait stability between the before and after exercise, values of variability were determined in a coefficient of variance. The magnitude of frequency and variability analysis for media-lateral signal revealed significantly less after exercise (p<.05). In contrast, variability of this signal's frequency that have used to evaluate the local stability during walking exhibited significantly greater after exercise(p<.05). In summary, magnitude frequency and variability of media-lateral ground reaction force's signal were significantly changed after a 12-week elastic resistance exercise.

"A study on the Time-Frequency Algorithm to estimate time-varying Power Spectrum of Heart Rate Variability Signals" (심박변동신호의 시변파워스펙트럼 추정을 위한 Time-Frequency 알고리즘에 관한연구)

  • Park, C.S.;Lee, J.W.;Lee, J.Y.;Kim, J.S.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.185-186
    • /
    • 1998
  • The discrete Wigner-distribution(DWD) was implemented for the time-frequency analysis of heart rate variability signals. The smoothed cross-DWD was used to estimate time-varying power spectrum. Spurious cross-terms were suppressed using a smoothing data window and a Gauss frequency window. The DWD is very easy to implement using the FFT algorithm. Experiment show that the DWD follows well the instantaneous changes of spectral content of heart rate variability signals, which characterize the dynamics of autonomic nervous system response.

  • PDF

Variability of Seismic Demand According In the Selection the Earthquake Ground Motion Groups (지진기록 선택에 따른 요구지진 하중의 변화)

  • 황수민;한상환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.417-422
    • /
    • 2004
  • It is the challenging task to predict seismic demand for structural design. In current seismic design provisions such as UBC, NEHRP, ATC 3-06, the seismic demand is calculated using the response spectrum with response modification factor (R). This paper investigates variability of seismic demand according to selecting the earthquake ground motion groups. Different Earthquake sets used by Miranda, Riddell and Seed selected were used in this study. Earthquake sets selected by authors include 62 sets of near field ground motion and 19 sets one pulse ground motion. Linear Elastic Response Spectrum (LERS), the variation of performance points of calculated by Capacity Spectrum Method (CSM) were considered with respect to the different sets of earthquake ground motions.

  • PDF

STANDARIZING THE EXTRATERRESTRIAL SOLAR IRRADIANCE SPECTRUM FOR CAL/VAL OF GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Shanmugam, Palanisamy;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.86-89
    • /
    • 2006
  • Ocean color remote sensing community currently uses the different solar irradiance spectra covering the visible and near-infrared in the calibration/validation and deriving products of ocean color instruments. These spectra derived from single and / or multiple measurements sets or models have significant discrepancies, primarily due to variation of the solar activity and uncertainties in the measurements from various instruments and their different calibration standards. Thus, it is prudent to examine model-to-model differences and select a standard reference spectrum that can be adopted in the future calibration and validation processes, particularly of the first Geostationary Ocean Color Imager (GOCI) onboard its Communication Ocean and Meterological Satellite (COMS) planned to be launched in 2008. From an exhaustive survey that reveals a variety of solar spectra in the literature, only eight spectra are considered here seeing as reference in many remote sensing applications. Several criteria are designed to define the reference spectrum: i.e., minimum spectral range of 350-1200nm, based completely or mostly on direct measurements, possible update of data and less errors. A careful analysis of these spectra reveals that the Thuillier 2004 spectrum seems to be very identical compared to other spectra, primarily because it represents very high spectral resolution and the current state of the art in solar irradiance spectra of exceptionally low uncertainty ${\sim}0.1%.$ This study also suggests use of the Gueymard 2004 spectrum as an alternative for applications of multispectral/multipurpose satellite sensors covering the terrestrial regions of interest, where it provides spectral converge beyond 2400nm of the Thuillier 2004 spectrum. Since the solar-activity induced spectral variation is about less than 0.1% and a large portion of this variability occurs particularly in the ultraviolet portion of the electromagnetic spectrum that is the region of less interest for the ocean color community, we disregard considering this variability in the analysis of solar irradiance spectra, although determine the solar constant 1366.1 $Wm^{-2}$ to be proposed for an improved approximation of the extraterrestrial solar spectrum in the visible and NIR region.

  • PDF

Human Sensibility Measurement for Visual Picture Stimulus using Heart Rate Variability Analysis (심박변화 분석을 이용한 장면시자극에 대한 감성측정에 관한 연구)

  • 권의철;김동윤;김동선;임영훈;손진훈
    • Science of Emotion and Sensibility
    • /
    • v.1 no.1
    • /
    • pp.93-103
    • /
    • 1998
  • In this paper, we present change of human sensiblity when the 26 healthy female subjects were exposed with visual picture stimulus. We used Intermational Affective Picture System as the visual stimulus. The methods are AutoRegressive(AR) spectrum which is a linear method and Return Map which is a nonlinear mithod. SR spectrum may variability(HRV). The LF/HF of HRV and the variation of Return Map were analyzed from ECG signal of the female subjects. Return Map of RR intervals were analyzed by computiong the variation. When the subjets were stimulated by the pleasant pictures, LF/HF and variation were decreased compared with unpleasant stimulus, We may obtain good parameters for the measurement of the change of human sensibility for the visual picture stimulus.

  • PDF

Work Load Dependency of Heart Rate Variability (HRV) (심박변이도의 운동부하 의존성)

  • Kwon J.H.;Kim C.S.;Eom G.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.641-642
    • /
    • 2006
  • The purpose of this work is to investigate the effect of work load on heart rate variability (HRV) which is widely used marker of the autonomic nervous system activity. Average heart rate, rating of perceived exertion, and the power spectrum of heart rate variability were investigated in seven healthy males during exercise at various work loads. The subjects were divided into two groups according to the average heart rate during exercise, group 1 with lower heart rate and group 2 with higher heart rate. HF component showed decrease followed by increase with workload. Accordingly, the LF/HF ratio showed increase followed by decrease with workload. The peak in LF/HF ratio of group 1 was at the lower workload than that of group 2.

  • PDF

Assesment of Mental Fatigue during Monotous Task (단조 작업에 의한 정신 피로의 평가 - 생리신호를 중심으로 -)

  • 윤용현;고한우;김동윤;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.222-226
    • /
    • 1999
  • 단조 작업에 의한 정신적 부하의 평가를 위하여 피험자에게 3자릿수 숫자 3개를 더하는 연산 작업을 수행하게 하였다. 작업 시간이 증가함에 따라 단조감이 증가하도록 실험과정을 설계하였고 수행한 작업이 단조 작업임을 주관적 설문지를 사용하여 증명하였다. 작업 수행시 발생된 부하를 평가하기 위하여 생리신호를 측정하였다. 측정된 생리신호 중 Electrocardiogram, skin-temperature, temperature, respiration을 먼저 분석하였다. 단조 작업을 수행함에 따라 skin-temperature의 증가 경향이 나타났으며, heart rate variability의 power spectrum의 HF성분의 감소와 LF/HF비의 증가 경향이 나타났다. 특히 skin-temperature와 heart rate variability의 power spectrum의 HF성분은 주관적 평가치와 상관관계도 비교적 높게 나타났다.

  • PDF

Analysis of Variability for the Components of VGRF Signal via Increasing the Number of Attempt during Running (달리기 시도 수 증가에 따른 VGRF 신호 성분의 Variability 분석)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.129-134
    • /
    • 2007
  • The purpose of this study was to determine the variability of components of the vertical ground reaction force signal to seek the suitable number of attempt datum to be analyzed during running at 2m/s and 4m/s. For this study, six subjects (height mean:$174.5{\pm}4.4cm$, weight $671.5{\pm}116.4N.$, age:$25.0{\pm}yrs.$) were selected and asked to run at least 3 times each run condition randomly. FFT(fast Fourier transform) was used to analyze the frequency domain analysis of the vertical ground reaction forces signal and an accumulated PSD (power spectrum density) was calculated to reconstruct the certain signal. To examine the deviation of the vertical ground reaction between signals collected from an different number of attempt, variability of frequency, magnitude of passive peak, time up to the passive peak and maximum load rate were determined in a coefficient of variance. The variability analysis revealed that when analyze the vertical reaction force components at 2m/s speed running, which belongs to slow pace relatively, it would be good to calculate these components from signal of one attempt, but 4m/s speed running needs data collected from two attempts to decrease the deviation of signal between attempts. In summary, when analyzing the frequency and passive peak of the vertical reaction force signal during the fast run, it should be considered the number of attempt.