• 제목/요약/키워드: vane number

검색결과 85건 처리시간 0.027초

미분탄 분리장치의 성능에 영향을 미치는 설계인자 (The effect of design parameters on the pulverized coal separator efficiency)

  • 이건명;하종광;안상택;이익형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.385-389
    • /
    • 2003
  • Three-dimensional experimental analysis was conducted in the pulverizer simplified isothermal model. The experiment model was constructed on a 1/3.5 scale of 500MW pulverizer. The purpose of this study is to investigate the effect of design parameters on the pulverized coal separator efficiency. Where used pulverized coal separator design parameters are guide vane angle, static classifier angle, dynamic classifier rpm. Taguchi method was used to find the effective design parameters related to pulverized coal separator efficiency. The results of the experiment showed that guide vane angle and dynamic classifier rpm were the design key parameters. In addition to the total number of experiment cases were reduced by Taguchi method.

  • PDF

마그네트론 양극의 온간성형 공정의 UBET해석 (A UBET Analysis of The Warm Forming Process of Magnetron Anode)

  • 조관형;배원병;김영호;양동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.204-208
    • /
    • 1995
  • Copper magnetron anode of a microwave-oven consists of an cylindrical outer-tube and various inner-vanes. The magnetron anode is produced by the complex process ; vane blanking, pipe cutting and sliver-alloy brazing of vanes. Recently, the backward extrusion process for forming vanes has been developed to avoid the complex procedures. The developed process is analyzed by using upper-bound elemental technique(UBET). In the UBET analysis, the upper-bound load, the configuration and the vane-height of final extruded product are determined by minimizing the total power consumption with respect to chosen parameters. To verify theoretical analysis, experiments have been carried out with pure plasticine billets at room temperature, using different web-thickness and number of vanes. The theoretical predictions both for forming load and vane-height are in reasonable agreement with the experimental results.

  • PDF

소수력 발전용 프란시스 수차의 수력학적 성능에 관한 연구 (A Study on Hydraulic Performance of Francis Turbine for Small Hydropower Plants)

  • 최주석;김일수;문채주;김옥삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.687-689
    • /
    • 2005
  • Francis turbine of commercial small hydro -power plants under 10kw which is investigate a flow characterist and an efficiency in the research which it sees, the problem and an improvement is investigate. In the research which it is simply model with casing, guide-vane, runner, draft tube for simulation numerical analysis of small-sized Francis turbine. model uses the Gambit and it composes with approximately 800,000 nonuniform lattices. Solutions are investigate the hydraulic characteristics against an outward angle of guide vane, the number of guide vane, head(inlet velocity) by using FLUENT which is a commercial business code.

  • PDF

PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계 (Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements)

  • 성재용;안광협;이기섭;최호선;이인섭
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

곡면 끝벽을 갖는 터빈 노즐 안내깃 캐스케이드내 3차원 유동장에 관한 실험적 연구 (Experimental Study on Effects of the Contoured Endwall on the Three-Dimensional Flow in a Turbine Nozzle Guide Vane Cascade)

  • 윤원남;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1975-1980
    • /
    • 2004
  • The three-dimensional flow in a turbine nozzle guide vane passage causes large secondary loss through the passage and increased heat transfer on the blade surface. In order to reduce or control these secondary flows, a linear cascade with a contoured endwall configuration was used and changes in the three-dimensional flow field were analyzed and discussed. Measurements of secondary flow velocity and total pressure loss within the passage have been performed by means of five-hole probes. The investigation was carried out at fixed exit Reynolds number of $4.0{\times}10^5$. The objective of this study is to document the development of the three-dimensional flow in a turbine nozzle guide vane cascade with modified endwall. The results show that the development of passage vortex and cross flow in the cascade composed of one flat and one contoured endwalls are affected by the flow acceleration which occurs in contoured endwall side. The overall loss is reduced near the flat endwall rather than contoured endwall.

  • PDF

항공기용 가스터빈의 고압 냉각터빈 노즐에 대한 복합열전달 해석 (Conjugate Heat Transfer Analysis for High Pressure Cooled Turbine Vane in Aircraft Gas Turbine)

  • 김진욱;박정규;강영석;조진수
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.60-66
    • /
    • 2015
  • Conjugate heat transfer analysis was performed to investigate the flow and cooling performance of the high pressure turbine nozzle of gas turbine engine. The CHT code was verified by comparison between CFD results and experimental results of C3X vane. The combination of k-${\omega}$ based SST turbulence model and transition model was used to solve the flow and thermal field of the fluid zone and the material property of CMSX-4 was applied to the solid zone. The turbine nozzle has two internal cooling channels and each channel has a complex cooling configurations, such as the film cooling, jet impingement, pedestal and rib turbulator. The parabolic temperature profile was given to the inlet condition of the nozzle to simulate the combustor exit condition. The flow characteristics were analyzed by comparing with uncooled nozzle vane. The Mach number around the vane increased due to the increase of coolant mass flow flowed in the main flow passage. The maximum cooling effectiveness (91 %) at the vane surface is located in the middle of pressure side which is effected by the film cooling and the rib turbulrator. The region of the minimum cooling effectiveness (44.8 %) was positioned at the leading edge. And the results show that the TBC layer increases the average cooling effectiveness up to 18 %.

스월변화에 따른 모형 가스터빈 연소기의 열유동장의 실험적 연구 (Experimental Study of Thermo-Flow Field in a Model Gas Turbine Combustor with Various Swirl Conditions)

  • 류송열;구자예
    • 한국항공우주학회지
    • /
    • 제30권4호
    • /
    • pp.70-76
    • /
    • 2002
  • 가스터빈 연소기의 스월러와 노즐을 제작하여 스월러 형상 변화에 따른 비연소시 케로신 분무 특성과 연소시에 열유동장의 특성을 조사하였다. 액적의 크기(SMD)와 속도를 파악하기 위해서 위상도플러입자분석기(PDPA)를 이용하였고, 연소 온도를 조사하기 위해서 R-type 열전대(Platinum vs. Platinum-13%rhodium)를 이용하였다. 분무와 화염의 가시화는 스틸 카메라를 이용하였다. 스월러각이 커서 스월수가 큰 경우에 분무 및 화염이 반경방향으로 빠르게 발전하였다. 화염은 스월수가 작을 때는 원추형의 화염이 형성되지만 스월수가 커지면서 스월 모멘텀이 중심축으로 이송되고 혼합이 촉진되어 원통형으로 바뀌었다.

가스터빈 노즐 베인의 열전달 예측을 위한 벽면처리법 비교연구 (Comparative Study of Near-Wall Treatment Methods for Prediction of Heat Transfer over Gas Turbine Nozzle Guide Vane)

  • 박정규;김진욱;이세욱;강영석;조이상;조진수
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.639-646
    • /
    • 2014
  • 난류모델에서 벽면처리법이 터빈 노즐 베인의 열전달 예측에 미치는 영향을 비교 분석하였다. 본 연구를 위해 NASA의 C3X 터빈 노즐 베인을 사용하였다. 벽함수 방법, 저레이놀즈수 방법, 천이모델을 사용하여 베인 표면에서의 압력 및 온도를 해석하였다. 해석 결과 터빈 노즐 베인의 중간 압력분포는 각 벽면처리법에 따른 차이 없이 실험값과 잘 일치하였다. 그러나 터빈 노즐 베인의 온도와 열전달 계수는 각 벽면처리법에 따라 큰 차이를 보였다. 전반적으로 저레이놀즈수 방법과 천이모델은 벽함수 방법에 비해 온도 및 열전달 계수 예측에 특별한 이점을 보이지 않았으며, 벽함수 방법을 적용한 레이놀즈응력 난류모델이 터빈 노즐 베인 표면의 온도 및 열전달 계수를 비교적 잘 예측하였다.

이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토 (Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly)

  • 이치영
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2017
  • 이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능을 실험적으로 평가하였다. 비틀림 혼합날개 지지격자는 부수로 간 혼합뿐 아니라 부수로 내 혼합을 동시에 증대시킬 수 있도록 설계되었다. 실험을 위한 이중냉각 환형핵연료 모의 집합체로, 봉 중심 간 거리와 봉 외경의 비가 1.08인 봉 간격이 좁은 $4{\times}4$ 정사각 배열의 봉다발을 준비하였다. 실험은 봉다발 유동의 축방향 평균속도가 1.5 m/s, 열유속은 $26kW/m^2$인 조건에서 수행하였다. 원주방향 온도 분포의 경우, 지지격자 상류에서는 부수로 중심 벽면에서, 하류에서는 비틀림 혼합날개 끝이 향하는 벽면에서 온도가 가장 낮게 나타났다. 축방향 온도 분포의 경우, 지지격자 하류 근처에서 온도가 급격하게 감소하는 것으로 측정되었고, 비틀림 혼합날개에 의해 누셀트 수는 최대 56 % 증대되는 것으로 나타났다. 본 실험결과를 토대로 봉 간격이 좁은 이중냉각 환형핵연료 집합체에서 비틀림 혼합날개 지지격자에 의해 강제대류열 전달 성능이 효과적으로 증대될 수 있음을 확인하였다.

소수력 발전용 상용 프란시스 수차의 유동해석을 통한 성능 개선에 관한 연구 (A Study on Hydraulic Performance of Francis Turbine for Small Hydropower Plants)

  • 최주석;김옥삼;김일수;전철균;문채주
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.19-25
    • /
    • 2005
  • Francis turbine of commercial small hydropower plants under 10kw which is investigate a flow characterist and an efficiency in the research which it sees, the problem and an improvement is investigate. In the research which it is simply model with casing, guide-vane, runner, draft tube for simulation numerical analysis of small-sized Francis turbine. Model uses the Gambit and it composes with approximately 800,000 non-uniform lattices. Solutions are investigate the hydraulic characteristics against an outward angle of guide vane, the number of guide vane, head(inlet velocity) by using FLUENT which is a commercial business code.