• Title/Summary/Keyword: value measurement

Search Result 4,742, Processing Time 0.031 seconds

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

Development of a Model System of Uncertainty Evaluations for Multiple Measurements by Isotope Dilution Mass Spectrometry: Determination of Folic Acid in Infant Formula

  • Kim, Byung-Joo;Hwang, Eui-Jin;So, Hun-Young;Son, Eun-Kyung;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3139-3144
    • /
    • 2010
  • A model system has been established for the evaluation of the uncertainty of the value from measurements of multiple subsamples by isotope dilution mass spectrometry (IDMS). In this report, we apply this model system for the evaluation of measurement uncertainty in determination of folic acid in infant formula. Five subsamples were analyzed by IDMS. The mean of the measurement results of the five subsamples was assigned as the final measurement value. The standard deviation (s) of the results from five subsamples was attributable to repeatability of the measurement. The uncertainty components in the IDMS measurement methods were categorized into two groups. Group I includes uncertainty components which give common systematic effects to all subsamples and do not contribute to the variation among multiple measurements (repeatability). Group II includes uncertainty components that give random effects on the measurement results, and are related with the measurement repeatability. These random effects are attributed to s. Therefore, the uncertainty of the final value was calculated by combining the standard deviation of the mean of multiple measurements, $s/{\surd}n$ (where n = 5), and the measurement uncertainty associated with the uncertainty components that give systematic effects.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Construction Progress Measurement System by tracking the Work-done Performance (내역물량 측정에 의한 건설공사진도율 산정시스템)

  • Choi Yoon-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.3 s.15
    • /
    • pp.137-145
    • /
    • 2003
  • The project control system based on the actual values of three objects shall be operated continuously in a timely manner. For collecting/tracking accurate actual performance data, a reasonable basis of measuring work performance and its related measuring methods are needed. Therefore, this research proposes a method of developing and operating the construction progress measurement system. The problem of the conventional method is the difficulty to construct control accounts and to define the basis of measuring the performance of each control account. Therefore, this research proposes the preferable, formal methodology that produces the progress value of the smallest work unit by surveying the installed quantities and estimates percent complete of groups of works or entire project by earned value concept. This research in connection with the hereafter research of the weight value of control accounts will contribute to apply in practice and to develop the scientific construction management technique in the construction industry. Further researches how to trend and forecast the project using the measured progress value are recommended for putting the prosed system of this research to practical use.

Measuring CSV Performance: An Explorative Study on Strategic Activities in Converged Home Appliance Industry (공유가치창출을 위한 가전산업의 전략적 활동 및 성과 측정에 관한 연구)

  • Lee, Hye Sun;Park, Soo Kyung;Cho, Ji Yeon;Kim, Taisiya;Lee, Bong Gyou
    • Journal of Internet Computing and Services
    • /
    • v.16 no.3
    • /
    • pp.117-126
    • /
    • 2015
  • The concept of Creating Shared Value (CSV) has emerged as a solution for companies' sustainable growth and social problems through collaboration of business activities and social demand. Therefore, studies on shared value creativity and measurement of companies' performances are required. However, most recent studies have applied the CSV concept to existing business models or measure shared value considering only economic value. Few studies have considered the appropriateness of applying the CSV or discussed performance measurement with respect to industry characteristics. This study selects the industry expected to have the greatest created value with applying the CSV, and then suggests measurement of performance in this industry. First, through the expert interview, the study selects one from among South Korea's 10 main industries, which is expected to solve social demand through convergence with the IT industry, and to create new value for a traditional industry. The Home Appliance industry was selected as appropriate, because it has industrial growth stagnation under the smart environment. Moreover, it is facing problems such as energy savings and environmental issues. The study goes on to suggest, based on Michael Porter's three strategic levels, measurement variables of the value creation process and performance. This study has limitations from an empirical perspective. However, as the interest of applying CSV to business is growing, it is meaningful to explore the CSV strategies activities and measurement performance based on industry-specific characteristics.

Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant (수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교)

  • Lim, Hyoung-Sup;Kim, Su-Gwan;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

Uncertainty in Potentiodynamic Polarization Resistance Measurement (동전위 분극저항 측정에서의 불확도)

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

A Study on the Laser Measurement Experiment for Performance Advancement of Tilting Index Table (틸팅 인덱스 테이블의 성능 향상을 위한 레이저 측정 실험에 관한 연구)

  • Kim, Kwang-Sun;Lee, Tae-Ho;Lee, Choon-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.26-30
    • /
    • 2011
  • Currently, many researches are carried out about tilting index table, which is one of the main component of 5-axis machine tool. The performance of the tilting index table is associated the rotational accuracy which is very important factor for high precision machining because it have an effect on machining error. In this paper, a tilting index table is developed, and the rotational accuracy of the tilting index table using a laser measurement equipment is measured. In addition, a correction value is obtained from the measured value through compensation, and the correction value is used to improve the accuracy of the table. Comparative analysis is carried out for the accuracy of the table before and after compensation. This paper can be used by a reference for performance and reliability advancement of tilting index table.

A Text Similarity Measurement Method Based on Singular Value Decomposition and Semantic Relevance

  • Li, Xu;Yao, Chunlong;Fan, Fenglong;Yu, Xiaoqiang
    • Journal of Information Processing Systems
    • /
    • v.13 no.4
    • /
    • pp.863-875
    • /
    • 2017
  • The traditional text similarity measurement methods based on word frequency vector ignore the semantic relationships between words, which has become the obstacle to text similarity calculation, together with the high-dimensionality and sparsity of document vector. To address the problems, the improved singular value decomposition is used to reduce dimensionality and remove noises of the text representation model. The optimal number of singular values is analyzed and the semantic relevance between words can be calculated in constructed semantic space. An inverted index construction algorithm and the similarity definitions between vectors are proposed to calculate the similarity between two documents on the semantic level. The experimental results on benchmark corpus demonstrate that the proposed method promotes the evaluation metrics of F-measure.