• Title/Summary/Keyword: value measurement

Search Result 4,752, Processing Time 0.031 seconds

A study on the Automatic Detection of the Welding Dimension Defect of Steel Construct using Digital Image Processing (디지털 화상처리에 의한 강.구조물의 용접부 치수 결함 검출의 자동화에 관한 연구)

  • Kim, Jae-Yeol;You, Sin;Park, Ki-Hyung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.3
    • /
    • pp.92-99
    • /
    • 1999
  • The inspection unit which is developed and used in this study, is processed the shape data from the CCD camera to seek welding bite section shape, and then calculated as a real dimension from measuring the value of each inspection item. The reason of measuring with the real in this study is came out from the image method which used for a long time, which is extricated the characteristic as the dimension of pixel by recognize pixel. The measurement method of the section shape is that we decide the thresholding value after we drew the histogram to binarizate the object. After that, we make flat the object to get rid of the noise and measure the shape of welded part through the boundarization of the object. The shape measurement is that measure the value of the welding part to adapt the actual operation program from using the ratio between the actual dimension of the standard specimen and the dimension of image, to measure the ratio between the actual product and the camera image. The inspection algorithm which estimates the quality of welded product is developed and also, the software GUI(Graphic User Interface) which processes the automatic test function of the inspection system is developed. We make the foundation of the inspection automatic system and we will help to apply other welding machine.

  • PDF

The Effect of Mutual Coupling between Current and Potential Test Leads on Ground Impedance (전류 및 전위 측정선간 상호유도가 접지임피던스에 미치는 영향)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1223-1228
    • /
    • 2008
  • While a high frequency source is used for measuring the ground impedance, there are several factors having an effect on the measured value. A primary factor of the measurement error is the ac mutual coupling between current and potential test leads. The mutual coupling causes the test current to induce a voltage into the potential test lead that adds to the actual ground potential rise and produces a significant measurement error as the length of the test leads paralleled is prolonged. In order to avoid the mutual coupling, it is recommended that the ground impedance be measured by angled arrangement of test leads. The mutual impedance due to the inductive coupling with an angle of $90^{\circ}$ was calculated at $0^{\circ}$ by Campbell/Foster Method. With an angle of $180^{\circ}$, the mutual impedance was calculated large value enough to introduce a fairly large margin of error, however, the measured value of ground impedance was close to the value at $90^{\circ}$.

A study on the Intake-Balance of Iron Copper and Cobalt of College men in Korea (한국 남자대학생의 Iron, Copper 및 Cobalt 섭취량과 평형에 관한연구)

  • 최인선;장수영;오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.5
    • /
    • pp.418-428
    • /
    • 1990
  • This study measured each daily intake and excretion of iron copper and cobalt of eight 20-26 years old college men during four weeks by means of analyzing their food intake urine and feces keeping their normal living pattern and maintenance body weight. This study also compared the actual measurement value of iron intake by atomic absorption spectrophoto-meter with the conversion value of it by food table. The results were as follows. Each person's average intake daily was iron 9.19±0.32mg/day, copper 0.56±0.06mg/day and cobalt 1.86±0.18mg/day. Each person's average urinary excretion daily was iron 0.53±0.07mg/day, copper 0.07±0.03mg/day and cobalt 0.13±0.01mg/day. Each person's average fecal excretion daily was iron 1.73±0.14mg/day copper 0.16±0.01mg/day and cobalt 0.46±0.08mg/day. The actual measurement value was 9.19±0.32mg/day and its conversion value 14.07±0.29mg/day : the former was 35% lower than the latter.

  • PDF

A Study on Control system design for Automated Cultivation of product (농작물 재배 자동화를 위한 제어시스템 설계에 관한 연구)

  • Cho, Young Seok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.1
    • /
    • pp.55-60
    • /
    • 2014
  • Today, there is increasing the elderly population in rural community, and people of returning from the urban to the rural community are demand to be of high value-added agriculture. In this time, there are required to regularization, standardization, automation, for getting of production of high value crops. In this paper, we are study for automation cultivation control system design for produce high-value crops. this system were designed of two parts that one part is measure and control unit, another part is server part for database and server side control. the main controller for measurement and control is used MC9S08AW60, server for Database and server-side control was using MySQL with CentOS. The source code of control program was coding C and compile with GCC. the functions of measurement and control unit are digital input and output each 8channels and can be scan-able of 20 Bit with 2CH/Sec. Analog Output were designed that can be output of 4-20mA or 0-5V on 4channel. The Digital input and output part were designed 8-channel, and using the high speed photo coupler and relays. We showed that system is possible to measure a 20bit data width, 2Ch/sec as 8 channel analog signals.

A Study on the Valuation of Call Quality in Korean Mobile Communication Industry

  • Kim, Mincheol;Lee, Hyungseok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.7A
    • /
    • pp.1275-1283
    • /
    • 2001
  • The purpose of this paper is to test whether prices of mobile communication service reflect their varying degrees of call quality, controlling for other service attributes. As, in fact, service is intangible goods difficult to measure its value, this paper makes use of econometric model, hedonic price analysis. Hedonic price analysis, has ever been applied in public or environmental economics, is employed and produces estimates of the prices (or the contributions toward the total price) for each characteristic. This paper applied hedonic technique to the value measurement of a service property for the use of Korean mobile communication. This paper uses actual transaction prices of mobile communication service to determine whether or not the market functions in pricing call quality of mobile communication service. Finally, this show that the willingness to pay of consumer increases as call quality increases and so market makes prices on call qualities. Thus, major concern in this paper is about value measurement o service quality, and also suggest of the possibility to determine call quality value (or price) of mobile communication service.

  • PDF

Analysis of naturally Dyed Textile Fabrics by using Aronia Extract (아로니아 추출물에 의한 직물의 천연염색과 염액의 Spectrum 분석)

  • Won, Ah Young;Kim, Jongjun
    • Journal of Fashion Business
    • /
    • v.22 no.1
    • /
    • pp.124-134
    • /
    • 2018
  • This study examined the dyeing characteristics and spectrum of cotton and silk by using dyeing solution extracted from aronia. The value $L^{\ast}$ which indicates the brightness of cotton regardless of mordant increases with increasing pH from pH 3.5 to pH 10.5. The color difference value(${\Delta}E$) of the cotton was generally high in pH 3.5 regardless of mordant existence. The silk showed the highest ${\Delta}E$ value in pH 3.5 dye solution as cotton did. On the other hand, the silk with mordant dyed showed the highest ${\Delta}E$ value in pH 7. Silk fabrics dyed with Aronia solution turns out red in pH 3.5, blue in pH 7 and yellow in pH 10.5. This is because of the amino acid, one of the silk ingredients, combines with a part of anthocyanin to show blue. As the result of the spectrum measurement, the maximum absorption wavelength of Aronia solution was increased in the order of pH 10.5, pH 3.5 and pH 7, regardless of extraction temperature and mordant. The measurement results of color fastness to washing and color fastness to light are generally low. Therefore, there is a need for further study to improve color fatness in the future.

An Analysis on Characteristics and the Development of Estimation Model of Internal Heat Gain from Appliances in Apartment Units (공동주택 단위세대의 기기발열 특성 분석 및 추정모델 개발)

  • Lee, Soo-Jin;Jin, Hye-Sun;Kim, Sung-Im;Lim, Han-Young;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.19-26
    • /
    • 2018
  • The purpose of this study was to analyze characteristics and to develop estimation model of IHG(Internal Heat Gain) from appliance in domestic apartment units. To do this, it was defined the source of IHG from appliance and the calculation method through the case study of international and domestic codes. And the equipment related datum such possession, usage or not, etc were collected through field survey in apartment units, and the appliances' electricity consumption were measured separately from overall electricity consumption. Annual electricity consumption value were calculated with field survey datum and appliances' electricity consumption measurement datum, and then IHG value was calculated by applying PHPP v9 method. And it was conducted correlation analysis between IHG value and the area for exclusive use, the number of occupants, and then the IHG from applianace estimation model was deducted with regression analysis. Finally, it was analyzed the present level and of the domestic code(The Building Energy Efficiency Rating System) comparing with the value of estimation model, and the various international codes(HERS, Building America, SAP).

The Wireless Radiation Measurement Using Embedded System (임베디드 시스템에 의한 방사선의 무선계측)

  • Kim, Hyong-Jong;Park, Dae-Sung;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Radiation is used in various field, including medical science, engineering science, agricultural science and other industrial fields and the use frequency of radiation is increasing thanks to the development of radiation technology. Although radiation contributes to the mankind so much, we must pay attention to radiation damage by its influence on human body. To use radiation properly and prevent the radiation damage, it is necessary to measure radiation exactly and to practice thorough research and education on the basis of this measurement. In this study, I suggest the method to measure radiation wirelessly without the limit of time and space, not approaching radiation having a harmful effect on human body by using ubiquitous computing technology. For the realization of suggested method, the wireless transmission technology of CDMA network is used and after installing embedded system in PDA, the measurement value is displayed through accessing CDMA network with PDA in radiation measurement system of having fixed IP. If we use the proposed method of this study, we don't have to approach radiation that is harmful to the human and can read the measurement value that is marked in PDA through CDMA network by radiation measurement system of having fixed IP.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution (수경배양액 무기성분농도 측정장치 개발)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Hong, Seung-Gil;Lee, Jae-Su;Baek, Jeong-Hyun;Park, Jong-Taek;Lee, Seung-Kee
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.