• Title/Summary/Keyword: validity index

Search Result 892, Processing Time 0.093 seconds

Business Relationships and Structural Bonding: A Study of American Metal Industry (산업재 거래관계와 구조적 결합: 미국 금속산업의 분석 연구)

  • Han, Sang-Lin;Kim, Yun-Tae;Oh, Chang-Yeob;Chung, Jae-Moon
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.3
    • /
    • pp.115-132
    • /
    • 2008
  • Metal industry is one of the most representative heavy industries and the median sales volume of steel and nonferrous metal companies is over one billion dollars in the case America [Forbes 2006]. As seen in the recent business market situation, an increasing number of industrial manufacturers and suppliers are moving from adversarial to cooperative exchange attitudes that support the long-term relationships with their customers. This article presents the results of an empirical study of the antecedent factors of business relationships in metal industry of the United States. Commitment has been reviewed as a significant and critical variable in research on inter-organizational relationships (Hong et al. 2007, Kim et al. 2007). The future stability of any buyer-seller relationship depends upon the commitment made by the interactants to their relationship. Commitment, according to Dwyer et al. [1987], refers to "an implicit or explicit pledge of relational continuity between exchange partners" and they consider commitment to be the most advanced phase of buyer-seller exchange relationship. Bonds are made because the members need their partners in order to do something and this integration on a task basis can be either symbiotic or cooperative (Svensson 2008). To the extent that members seek the same or mutually supporting ends, there will be strong bonds among them. In other words, the principle that affects the strength of bonds is 'economy of decision making' [Turner 1970]. These bonds provide an important idea to study the causes of business long-term relationships in a sense that organizations can be mutually bonded by a common interest in the economic matters. Recently, the framework of structural bonding has been used to study the buyer-seller relationships in industrial marketing [Han and Sung 2008, Williams et al. 1998, Wilson 1995] in that this structural bonding is a crucial part of the theoretical justification for distinguishing discrete transactions from ongoing long-term relationships. The major antecedent factors of buyer commitment such as technology, CLalt, transaction-specific assets, and importance were identified and explored from the perspective of structural bonding. Research hypotheses were developed and tested by using survey data from the middle managers in the metal industry. H1: Level of technology of the relationship partner is positively related to the level of structural bonding between the buyer and the seller. H2: Comparison level of alternatives is negatively related to the level of structural bonding between the buyer and the seller. H3: Amount of the transaction-specific assets is positively related to the level of structural bonding between the buyer and the seller. H4: Importance of the relationship partner is positively related to the level of structural bonding between the buyer and the seller. H5: Level of structural bonding is positively related to the level of commitment to the relationship. To examine the major antecedent factors of industrial buyer's structural bonding and long-term relationship, questionnaire was prepared, mailed out to the sample of 400 purchasing managers of the US metal industry (SIC codes 33 and 34). After a follow-up request, 139 informants returnedthe questionnaires, resulting in a response rate of 35 percent. 134 responses were used in the final analysis after dropping 5 incomplete questionnaires. All measures were analyzed for reliability and validity following the guidelines offered by Churchill [1979] and Anderson and Gerbing [1988]., the results of fitting the model to the data indicated that the hypothesized model provides a good fit to the data. Goodness-of-fit index (GFI = 0.94) and other indices ( chi-square = 78.02 with p-value = 0.13, Adjusted GFI = 0.90, Normed Fit Index = 0.92) indicated that a major proportion of variances and covariances in the data was accounted for by the model as a whole, and all the parameter estimates showed statistical significance as evidenced by large t-values. All the factor loadings were significantly different from zero. On these grounds we judged the hypothesized model to be a reasonable representation of the data. The results from the present study suggest several implications for buyer-seller relationships. Theoretically, we attempted to conceptualize the antecedent factors of buyer-seller long-term relationships from the perspective of structural bondingin metal industry. The four underlying determinants (i.e. technology, CLalt, transaction-specific assets, and importance) of structural bonding are very critical variables of buyer-seller long-term business relationships. Our model of structural bonding makes an attempt to systematically examine the relationship between the antecedent factors of structural bonding and long-term commitment. Managerially, this research provides industrial purchasing managers with a good framework to assess the interaction processes with their partners and, ability to position their business relationships from the perspective of structural bonding. In other words, based on those underlying variables, industrial purchasing managers can determine the strength of the company's relationships with the key suppliers and its state of preparation to be a successful partner with those suppliers. Both the supplying and customer companies can also benefit by using the concept of 'structural bonding' and evaluating their relationships with key business partners from the structural point of view. In general, the results indicate that structural bonding gives a critical impact on the level of relationship commitment. Managerial implications and limitations of the study are also discussed.

  • PDF

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.

Evaluation of Social Nicotine Dependence Using the Kano Test for Social Nicotine Dependence (KTSND-K) Questionnaire in Korea (Kano Test for Social Nicotine Dependence(KTSND-K) 설문지를 통한 한국인의 사회적 니코틴의존성의 평가)

  • Jeong, Jae Hee;Choi, Sang Bong;Jung, Wou Young;Byun, Min Gwang;Park, Moo Suk;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Yoshii, Chiharu;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.365-373
    • /
    • 2007
  • Background: Smoking is one of the most important leading causes of morbidity and mortality. Smoking habit is recognized as nicotine dependence, which consists of physical and psychosocial dependence. To evaluate social nicotine dependence, the Kano Test for Social Nicotine Dependence (KTSND) working group developed a new questionnaire, which consists of 10 questions with a total score of 30 in Japan. We examined the social nicotine dependence among healthy adults using the new KTSND questionnaire and evaluated validity of the KTSND questionnaire in Korea. Method: We applied Korean KTSND questionnaire version 2 to employees of hospital, university students and people for medical examination and promotion test. Complete data obtained from the 741 responders were analyzed. Result: The mean age of responders was 31.8 years. Among them, males were 57.8%. Current smokers, ex-smokers, and non-smokers were 13.8%, 12.8%, and 73.4% respectively. According to smoking status, the total KTSND scores of current smokers were significantly higher than those of ex-smokers, and of non-smokers ($17.1{\pm}5.4$ versus $14.3{\pm}5.5$, and $12.3{\pm}5.5$, $p{\leq}0.001$). The total KTSND scores of males were higher than those of females, suggesting that males have a propensity for depending nicotine socially much more than females ($14.3{\pm}5.7$ and $11.7{\pm}5.4$ respectively, p<0.001). Eight of ten questions produced significantly different scores among three different smoking groups. When current smokers were sub-classified by heavy smoking index (HSI) that represented physical nicotine dependence, we did not find a significant difference of KTSND score between low HSI group (<4) and high HSI group (${\geq}4$), This finding suggested that the psychosocial dependence might play a different role from physical nicotine dependence in smoking. Most of the non-smokers (62.5%) had an experience of harmful passive smoking especially in public place. Conclusion: Our study suggested that the KTSND questionnaire could be a useful method to evaluate psychosocial aspects of smoking.

A Study of the Relationship of Nurses' Personality Type and Job Satisfaction Level, according to the Career (근무경력별 간호사의 성격유형과 직무만족도와의 관련성(MBTI이용))

  • Park Young Sook;Park Kyung Min;Park Jeong Sook;Koh Hyo Jung;Kwon Young Sook;Kim Myung Ae;Kim Chung Nam;Park Cheong Ja;Shin Yeong Hee;Lee Kyung Hee;Lee Byung Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.15 no.2
    • /
    • pp.301-313
    • /
    • 2001
  • This study was to explore the relationship between nurses' personality type and their job satisfaction level. The subjects of the study were the 364 nurses who were serving at the general surgical department, psychiatric department, pediatric department and emergency room. The hospitals for which they were working were four university hospitals in Daegu and Busan, and six other university hospitals in Seoul were selected as sample hospitals. For data collection, questionnaires were self-reported to the subjects, under their agreement, from May to June, 2000. The following two instruments were used in the study: One was MBTI Test whose Korean version designed and verified to reliability and validity by Kim Jung Taek and Shim Hae Sook(1990): the other was the Nursing Job Satisfaction Instrument, 'The Index of Work Satisfaction' developed by Slavitt, et al.., (1978). The data were analyzed by frequency, t-test, one-way variance analysis, scheffe's post hoc contrast, and Pearson correlation coefficient with SPSS Win 10.0 program. The results this study were as follows ; 1. As a result of testing nurse's personality type by function at each career, it's found that the most personality type was expressed by the ST-type$(37.3\%)$ at 1-5 years, the SF-type$(29.4\%)$ at 6-10 years, the ST-type$(43.3\%)$ at more than 11 years. 2. As a result of testing the disparity in job satisfaction according to career, it appeared that the 6-10 years group showed higher job satisfaction, followed by the 6-10 years$(119.6\%),\;1-5 years(118.6\%)\;and\;more\;than\; 11 years(117.7\%)$ groups. 3. As a result of testing job satisfaction level according to nurse's personality type by function at each career, it's found that the most job satisfaction was expressed by the SF-type(F=8.50, p=0.00l) at 1-5 years. the ST-type(F=30.61, p=0.001) at 6-10 years. the SF-type(F=4.98, p=0.003) at more than 11 years groups. 4. As a result of testing a significant correlation between nurse's personality type by function and job satisfaction level. the SF(r=0.279, p=0.001) and ST(r=0.222, p=0.001) types showed significant positive correlation. and the NF(r=-0.201, p=0.001) and NT(r=-0.402, p=0.001) types revealed significant negative correlation. The nursing management is likely to be done more effectively, if managers in charge of nursing administration carefully reflect nurses' personal opinions in posting and personnel management, keeping in mind that there is a specific personality type that serves to raise job satisfaction at a specific career.

  • PDF

Salt-Related Dietary Attitudes, Behaviors, and Nutrition Knowledge of University Students according to Estimated Salt Intake Using Urinary Salt Signal (일부 남녀 대학생의 소변 중 Salt Signal로 추정한 소금 섭취량에 따른 소금 섭취 관련 식태도, 식행동, 영양지식에 관한 연구)

  • Kim, Mi-Hyun;Min, Daun;Jang, Eungyoung;Yeon, Jee-Young;Kim, Jong Wook;Bae, Yun-Jung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.2
    • /
    • pp.226-233
    • /
    • 2015
  • The purpose of this study was to evaluate salt-related dietary attitudes, behaviors, and nutrition knowledge according to urinary salt signal of university students. Based on urinary salt signal, we classified subjects into an "adequate Na intake (ANI)" group (n=52) (salt ${\leq}6g$) and "excess Na intake (ENI)" group (n=66) (salt >6 g). Subjects were asked about general characteristics, lifestyle, salt-related dietary attitudes, behaviors, and nutritional knowledge using questionnaire. The ENI group had more subjects who were drinkers (P<0.05) compared to the ANI group. The ENI group (33.45) showed a significantly lower score in terms of salt-related dietary attitudes compared to the ANI group (35.50) (P<0.05). There was no significant difference in the total score of salt-related dietary behavior between the groups. The score of nutrition knowledge was significantly higher in the ANI (9.77) group than in the ENI (8.82) group (P<0.05). The correlation analysis indicated that the urinary salt signal had a negative correlation with the salt-related dietary attitude score after adjustments for age, sex, and body mass index (r=-0.2100, P<0.05). These results support the validity of using the urinary salt signal to simplify estimation of sodium intake.

The Effect of Hospital Service Coordinator Education Curriculum on the Education Satisfaction and the Quality of Medical Service (병원서비스코디네이터 교육과정이 교육만족과 의료서비스 품질에 미치는 영향)

  • Choi, Eun-Kyoung;Park, Chang Sik;Seo, Jong-Bum
    • The Korean Journal of Health Service Management
    • /
    • v.2 no.1
    • /
    • pp.137-154
    • /
    • 2008
  • The increase of the supply of medical service and the increase of hospitals have intensified the competition of hospitals, and the advancement towards internationalization in the opening of medical industry has triggered the infinite competition of medical profession. In addition, the high expectation of customers and quality improvement in the medical care in accordance with the improvement of overall income, and the change of active role of medical consumers according to the popularization and the improvement of rights awareness reflect the customer needs and choice in the medical service. Customers wanted to receive the kind and pleasant service under the up-to-date medical service. Therefore, as a solution, hospital coordinators were emerged for the purpose of smooth treatment and customer satisfaction by generalizing all service of hospital. Accordingly, this thesis attempted to investigate the effect of hospital coordinator education curriculum on the education satisfaction and the quality of medical service. In order to solve the purpose of this study, I, author reviewed the existing literatures, established hypothesis, and verified hypothesis by using the variety of statistics techniques such as reliability, validity, frequency analysis, and regression analysis. The verification of hypothesis is as followings: First, among education training factors of hospital coordinators, the quality of instructor significantly affects the satisfaction of hospital coordinator education training. Second, among training factors of hospital coordinator, the attitude of trainee significantly affects the training satisfaction of hospital coordinator. Third, among education training factors of hospital coordinator, education course significantly affects the training satisfaction of hospital coordinator education. As the qualities of instructor are better equipped, the satisfaction of education becomes higher. It indicates that the education method of instructors is important as an index to represent the qualities of instructor such as the appropriateness of education method, preparation, passion, visual materials, the adequacy of education procession, and specialized knowledge, and it has important effect on the satisfaction of education. In order to enhance the satisfaction of hospital coordinator education, the creation of education environment, making trainee concentrate on the education, is required by appropriately allocating programs, arousing interest in education, based on the attitude of trainee, discussion, and preliminary programs, preparation, ahead of enforcement of education. Fourth, the satisfaction of hospital coordinator education training significantly affects the reliability among the qualities of medical service. Fifth, satisfaction of hospital coordinator education training significantly affects hospitality I kindness among the qualities of medical service. If the education satisfaction of trainee is high, it is effective in the practical application such as dealing with complaints, the duty performance for the patients, and so on in offering the medical service, related to reliability and furthermore, we can find the positive change in the attitude change of medical professions related to the reliability of hospital coordinator. In addition, in the process of offering medical services such as the kind explanation on the duty, rapid response to the customers inquiry, and tidy uniform, practical effect was verified. Sixth, the education training factor of hospital coordinator significantly affects the reliability among the quality of medical service. Seventh, the education training factors of hospital coordinator significantly affect hospitality/kindness. In the education of hospital coordinator, the methods to attract the interest of trainee by emphasizing reliability should be sought and for gaining the practical effect of hospital coordinator education, the sufficient preparation and investigation on the education curriculum should be prerequisite and under this condition, intensified discussion on the instructor and education course is needed. In the design of education course, more education hours and subjects should be allocated in the part of hospitality in order to improve the practical application of hospitality. Therefore, it is meaningful in a sense that this study newly approached the components of hospital coordinator education and the need to modify the quality components of medical service in accordance with the study subjects was raised. This study also finds its meaning in that it provides basic materials for the study of future hospital coordinator education by suggesting the system development model of hospital coordinator education through preliminary study of education training. In addition, this study is meaningful in the aspect that it suggested the direction of education training by showing how the hospital coordinator education training would applied to the hospital coordinator course of the Continuing Education Center at Pusan and Kyungnam National University to some extent. Since all investigation of this study was approached from the side of hospital coordinator, the thoughts of patients who are beneficiaries of medical service, and care givers cannot be identified. Therefore, the satisfaction of patients and care givers through the experience of medical service, which is the essential prerequisite of medical service, should be importantly considered and investigated. Accordingly, The study of comparing and analyzing the views of both patients and care givers should be carried out in the future.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

Accuracy of the 24-hour diet recall method to determine energy intake in elderly women compared with the doubly labeled water method (에너지 섭취 조사를 위한 24시간 회상법의 정확도 평가: 여자노인을 대상으로 이중표식수법을 이용하여)

  • Park, Kye-Wol;Go, Na-Young;Jeon, Ji-Hye;Ndahimana, Didace;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Eun-Kyung
    • Journal of Nutrition and Health
    • /
    • v.53 no.5
    • /
    • pp.476-487
    • /
    • 2020
  • Purpose: This study evaluated the accuracy of the 24-hour diet recall method for estimating energy intakes in elderly women using the doubly labeled water (DLW) method. Methods: The subjects were 23 elderly women with a mean age of 70.3 ± 3.3 years and body mass index (BMI) of 23.9 ± 2.8 kg/㎡. The total energy expenditure (TEEDLW) was determined by using the DLW and used to validate the 24-hour diet recall method. The total energy intake (TEI) was calculated from the 24-hour diet recall method for three days. Results: TEI (1,489.6 ± 211.1 kcal/day) was significantly lower than TEEDLW (2,023.5 ± 234.9 kcal/day) and was largely under-reported by -533.9 ± 228.0 kcal/day (-25.9%). The accurate prediction rate of elderly women in this study was 8.7%. The Bland-Altman plot, which was used to evaluate the TEI and the TEEDLW, showed that the agreement between them was negatively skewed, ranging from -980.8 kcal/day to -86.9 kcal/day. Conclusion: This study showed that the energy intake of elderly women was underreported. Strategies to increase the accuracy of the 24-hour diet recall methods in the elderly women should be studied through analysis of factors that affect underreporting rate. Further studies will be needed to assess the validity of the 24-hour diet recall method in other population groups.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Usefulness of the Chin Press Maneuver in Assessing the Severity of Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증후군의 진단에 있어 턱 압박술의 유용성)

  • Kim, Moo-Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.22-29
    • /
    • 2001
  • Objectives: Obstructive sleep apnea syndrome (OSA) is a moderately prevalent disorder. Even though much progress has been made in the diagnosis of this disorder, the cost-effectiveness of nocturnal polysomnography is undertermined and physicians and patients are still hesitant to undergo this procedure. The authors wanted to see the validity of chin press/tongue curl maneuver in estimating the severity of OSA which is easy to measure and was originally proposed by Simmons etc. by looking at the correlations between this score and the conventional respiratory disturbance indices. Methods: Forty-three sleep-related breathing disorder patients (28 OSA patients and 15 upper airway resistance syndrome (UARS) patients) who underwent investigation for posssible OSA were studied. Two conventional indices of OSA (apnea/hypopnea index (AHI) and oxygen saturation dip rate (SaO2 dips)), four other sleep variables (lowest SaO2, % of time with SaO2<90% (%SaO2 <90), % of sleep stage 1, mean length of SaO2 dips) and the score of Epworth sleepiness scale (ESS) were compared with the chin press score (CPS) which was newly revised by the author and ranges from 0 to 6. Results: The age of subjects was $45.95{\pm}12.47$ (range 14-76) and their average BMI was $25.98{\pm}3.61$ (range 19.65-37.64). There were no significant differences in age, sex and BMI except repiratory disturbance indices and ESS (p<0.05) between OSA and UARS group. Grouped median CPS of the all subjects was 4.14 (range 1-6). There was a remarkable relationship between CPS and diagnosis category (Likelihood Ratio $X^2$ test; $X^2$=17.41, df=5, p=0.004) and measures of association (Somers' $d=0.65{\pm}0.12$, t=4.83, p=0.000) indicated that CPS increased when the diagnosis changed from UARS to OSA. Spearman's rank correlations between CPS and SaO2 dips (R=0.83), between CPS and AHI (R=0.77) were good (p<0.001). Other variables except mean length of SaO2 dips showed good correlations with CPS as well (p<0.05). Regression analysis indicated that when CPS is 3 there is a provability of 0.35 to have AHI of less than 5. Conclusion: Chin press scores that can be measured easily is well correlation with the conventional sleep apnea indices. They may therefore provide a useful guide in diagnosing obstructive sleep apnea synrome.

  • PDF