• 제목/요약/키워드: vacuum chuck

검색결과 27건 처리시간 0.024초

저진공 축전 결합형 BCl3/N2 플라즈마를 이용한 GaAs의 건식 식각 (Capacitively Coupled Dry Etching of GaAs in BCl3/N2 Discharges at Low Vacuum Pressure)

  • 김재권;박주홍;이성현;노호섭;주영우;박연현;김태진;이제원
    • 한국재료학회지
    • /
    • 제19권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigates GaAs dry etching in capacitively coupled $BCl_3/N_2$ plasma at a low vacuum pressure (>100 mTorr). The applied etch process parameters were a RIE chuck power ranging from $100{\sim}200W$ on the electrodes and a $N_2$ composition ranging from $0{\sim}100%$ in $BCl_3/N_2$ plasma mixtures. After the etch process, the etch rates, RMS roughness and etch selectivity of the GaAs over a photoresist was investigated. Surface profilometry and field emission-scanning electron microscopy were used to analyze the etch characteristics of the GaAs substrate. It was found that the highest etch rate of GaAs was $0.4{\mu}m/min$ at a 20 % $N_2$ composition in $BCl_3/N_2$ (i.e., 16 sccm $BCl_3/4$ sccm $N_2$). It was also noted that the etch rate of GaAs was $0.22{\mu}m/min$ at 20 sccm $BCl_3$ (100 % $BCl_3$). Therefore, there was a clear catalytic effect of $N_2$ during the $BCl_3/N_2$ plasma etching process. The RMS roughness of GaAs after etching was very low (${\sim}3nm$) when the percentage of $N_2$ was 20 %. However, the surface roughness became rougher with higher percentages of $N_2$.

VLM-ST 공정의 완전 자동화를 위한 2단계 절단 경로 데이터 생성 방법에 관한 연구 (Generation of Cutting Path Data for Two Steps of the Cutting Process in Full- Automated VLM-ST)

  • 이상호;안동규;김효찬;양동열;박두섭;채희창
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.140-148
    • /
    • 2004
  • A novel rapid prototyping (RP) process, a full-automated transfer type variable lamination manufacturing process (Full-automated VLM-ST) has been developed. In the full-automated VLM-ST process, a vacuum chuck and a rectilinear motion system transfer the EPS foam material in the form of the plate with two pilot holes to the rotary supporting stage. The supplied material is then cut into an automated unit shape layer (AUSL) with a desired width, a desired length, a desired slope on the side surface, and a pair of reference shapes, which is called the guide shape (GS)’, including two pilot holes in accordance with CAD data through cutting in two steps using a four-axis synchronized hotwire cutter. Then, each AUSL is stacked by setting each AUSL with two pilot holes in the building plate with two pilot pins, and subsequently, adhesive is applied onto the top surface of the stacked AUSL by a bonding roller and pressure is simultaneously given to the bottom surface of the stacked AUSL. Finally, three-dimensional shapes are rapidly and automatically fabricated. This paper describes the method to generate guide shapes in AUSL data for the full-automated VLM-ST process. In order to examine the applicability of the method to generate guide shapes, three-dimensional shapes, such as a piston shape and a human head shape, are fabricated from the full-automated VLM-ST apparatus.

A High-speed Atomic Force Microscope for Precision Measurement of Microstructured Surfaces

  • Cui, Yuguo;Arai, Yoshikazu;Asai, Takemi;Ju, BinFeng;Gao, Wei
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.27-32
    • /
    • 2008
  • This paper describes a contact atomic force microscope (AFM) that can be used for high-speed precision measurements of microstructured surfaces. The AFM is composed of an air-bearing X stage, an air-bearing spindle with the axis of rotation in the Z direction, and an AFM probe unit. The traversing distance and maximum speed of the X stage are 300 mm and 400 mm/s, respectively. The spindle has the ability to hold a sample in a vacuum chuck with a maximum diameter of 130 mm and has a maximum rotation speed of 300 rpm. The bandwidth of the AFM probe unit in an open loop control circuit is more than 40 kHz. To achieve precision measurements of microstructured surfaces with slopes, a scanning strategy combining constant height measurements with a slope compensation technique is proposed. In this scanning strategy, the Z direction PZT actuator of the AFM probe unit is employed to compensate for the slope of the sample surface while the microstructures are scanned by the AFM probe at a constant height. The precision of such a scanning strategy is demonstrated by obtaining profile measurements of a microstructure surface at a series of scanning speeds ranging from 0.1 to 20.0 mm/s.

마이크로 스탬프를 이용한 Micro-LED 개별 전사 및리플로우 공정에 관한 연구 (A Study on Selective Transfer and Reflow Process of Micro-LED using Micro Stamp)

  • 한승;윤민아;김찬;김재현;김광섭
    • Tribology and Lubricants
    • /
    • 제38권3호
    • /
    • pp.93-100
    • /
    • 2022
  • Micro-light emitting diode (micro-LED) displays offer numerous advantages such as high brightness, fast response, and low power consumption. Hence, they are spotlighted as the next-generation display. However, defective LEDs may be created due to non-uniform contact loads or LED alignment errors. Therefore, a repair process involving the replacement of defective LEDs with favorable ones is necessitated. The general repair process involves the removal of defective micro-LEDs, interconnection material transfer, as well as new micro-LED transfer and bonding. However, micro-LEDs are difficult to repair since their size decreases to a few tens of micron in width and less than 10 ㎛ in thickness. The conventional nozzle-type dispenser for fluxes and the conventional vacuum chuck for LEDs are not applicable to the micro-LED repair process. In this study, transfer conditions are determined using a micro stamp for repairing micro-LEDs. Results show that the aging time should be set to within 60 min, based on measuring the aging time of the flux. Additionally, the micro-LEDs are subjected to a compression test, and the result shows that they should be transferred under 18.4 MPa. Finally, the I-V curves of micro-LEDs processed by the laser and hot plate reflows are measured to compare the electrical properties of the micro-LEDs based on the reflow methods. It was confirmed that the micro-LEDs processed by the laser reflow show similar electrical performance with that processed by the hot plate reflow. The results can provide guidance for the repair of micro-LEDs using micro stamps.

Pulsed DC $BCl_3/SF_6$ 플라즈마를 이용한 GaAs와 AlGaAs의 선택적 식각에 관한 연구

  • 최경훈;김진우;노강현;신주용;박동균;송한정;이제원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.67-67
    • /
    • 2011
  • Pulsed DC $BCl_3/SF_6$ 플라즈마를 사용하여 GaAs와 AlGaAs의 건식 식각을 연구하였다. 식각 공정 변수는 가스 유량 (50~100 % $BCl_3$ in $BCl_3/SF_6$), 펄스 파워 (450~600 V), 펄스 주파수 (100~250 KHz), 리버스 시간 (0.4~1.2 ${\mu}s$)이었다. 식각 공정 후 표면 단차 측정기 (Surface profiler)를 사용하여 표면의 단차와 거칠기를 분석하였다. 그 결과를 이용하여 식각률 (Etch rate), 표면거칠기 (Surface roughness), 식각 선택비 (Selectivity)와 같은 특성 평가를 하였다. 실험 후 주사 현미경 (FE-SEM, Field Emission Scanning Electron Microscopy)을 이용, 식각 후 시료의 단면과 표면을 관찰하였다. 실험 결과에 의하면 1) 18 sccm $BCl_3$ / 2 sccm $SF_6$, 500 V (Pulsed DC voltage), 0.7 ${\mu}s$ (Reverse time), 200 KHz (Pulsed DC frequency), 공정 압력이 100 mTorr인 조건에서 GaAs와 Al0.2Ga0.8As의 식각 선택비가 약 48:1로 우수한 결과를 나타내었다. 2) 펄스 파워 (Pulsed DC voltage), 리버스 시간(Reverse time), 펄스 주파수(Pulsed DC frequency)의 증가에 따라 각각 500~550 V, 0.7~1.0 ${\mu}s$, 그리고 200~250 KHz 구간에서 AlGaAs에 대한 GaAs의 선택비가 감소하게 되는 것을 알 수 있었다. 이는 척 (chuck)에 인가되는 전류와 파워를 증가시키고, 따라서 GaAs의 식각률이 크게 증가했지만 AlGaAs 또한 식각률이 증가하게 되면서 GaAs에 대한 식각 선택비가 감소한 것으로 생각된다. 3) 표면 단차 측정기와 주사전자현미경 사진 결과에서는 GaAs의 경우 10% $SF_6$ (18 sccm $BCl_3$ / 2 sccm $SF_6$)가 혼합된 조건에서 상당히 매끈한 표면 (RMS roughness < 1.0 nm)과 높은 식각률 (~0.35 ${\mu}m$/min), 수직의 식각 측벽 확보에서 매우 좋은 결과를 보여주었다. 또한 같은 공정 조건에서 AlGaAs는 식각이 거의 되지 않은 결과 (~0.03 ${\mu}m$/min)를 보여주었다. 위의 결과들을 종합해 볼 때 Pulsed DC $BCl_3/SF_6$ 플라즈마는 GaAs와 AlGaAs의 선택적 식각 공정에서 매우 우수한 공정 결과를 나타내었다.

  • PDF

Data Qualification of Optical Emission Spectroscopy Spectra in Resist/Nitride/Oxide Etch: Coupon vs. Whole Wafer Etching

  • Kang, Dong-Hyun;Pak, Soo-Kyung;Park, George O.;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.433-433
    • /
    • 2012
  • As the requirement in patterning geometry continuously shrinks down, the termination of etch process at the exact time became crucial for the success in nano patterning technology. By virtue of real-time optical emission spectroscopy (OES), etch end point detection (EPD) technique continuously develops; however, it also faced with difficulty in low open ratio etching, typically in self aligned contact (SAC) and one cylinder contact (OCS), because of very small amount of optical emission from by-product gas species in the bulk plasma glow discharge. In developing etching process, one may observe that coupon test is being performed. It consumes costs and time for preparing the patterned sample wafers every test in priority, so the coupon wafer test instead of the whole patterned wafer is beneficial for testing and developing etch process condition. We also can observe that etch open area is varied with the number of coupons on a dummy wafer. However, this can be a misleading in OES study. If the coupon wafer test are monitored using OES, we can conjecture the endpoint by experienced method, but considering by data, the materials for residual area by being etched open area are needed to consider. In this research, we compare and analysis the OES data for coupon wafer test results for monitoring about the conditions that the areas except the patterns on the coupon wafers for real-time process monitoring. In this research, we compared two cases, first one is etching the coupon wafers attached on the carrier wafer that is covered by the photoresist, and other case is etching the coupon wafers on the chuck. For comparing the emission intensity, we chose the four chemical species (SiF2, N2, CO, CN), and for comparing the etched profile, measured by scanning electron microscope (SEM). In addition, we adopted the Dynamic Time Warping (DTW) algorithm for analyzing the chose OES data patterns, and analysis the covariance and coefficient for statistical method. After the result, coupon wafers are over-etched for without carrier wafer groups, while with carrier wafer groups are under-etched. And the CN emission intensity has significant difference compare with OES raw data. Based on these results, it necessary to reasonable analysis of the OES data to adopt the pre-data processing and algorithms, and the result will influence the reliability for relation of coupon wafer test and whole wafer test.

  • PDF

O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각 (Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges)

  • 주영우;박연현;노호섭;김재권;이제원
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.85-91
    • /
    • 2009
  • 현재 플렉시블 폴리머를 이용한 MEMS (Microelectromechanical Systems) 기술이 빠르게 발전하고 있다. 그 중에서 Polycarbonate (PC), Poly Methyl Methacrylate (PMMA)와 같은 플렉시블 폴리머 재료는 광학적 특성이 우수하고 인체 친화적이며 미세 패턴 제조 공정이 용이하다는 등의 많은 장점을 가지고 있다. 본 연구는 반응성 이온 식각 기술을 이용하여 $O_2$, $SF_6$ 그리고 $CH_4$의 삼성분계 가스의 혼합 비율에 따른 PC와 PMMA의 건식 식각 결과 및 특성 평가에 관한 것이다. 준비한 각각의 기판에 포토리소그래피 방법으로 마스크를 형성하여 샘플을 만들었다. RF 척 파워를 100 W, 총 가스 유량을 10 sccm으로 고정시켜 플라즈마 식각 실험을 실시하였다. 그 결과에 의하면 전체적으로 PMMA의 식각율이 PC보다는 약 2배 정도 높았다. 그 결과는 PC는 PMMA 보다 상대적으로 높은 녹는점을 가지고 있다는 사실과 관계가 있다고 생각한다. 또한 $O_2/SF_6/CH_4$의 삼성분계 가스와 $SF_6/CH_4$, $O_2/SF_6$, $O_3/CH_4$로 나누었을 때 $O_2/SF_6$의 혼합 가스에서 PMMA와 PC의 식각 속도가 가장 높았다 (PC: 5 sccm $O_2$/5 sccm $SF_6$에서 약 350 nm/min, PMMA: 2.5 sccm $O_2$/7.5 sccm $SF_6$에서 약 570 nm/min). SEM을 활용하여 식각된 표면을 분석한 결과 PC는 PMMA보다 상대적으로 식각 표면이 더 매끈하였다. 또한 표면 거칠기 분석결과 PC의 표면 거칠기는 1.9$\sim$3.88 nm이었지만 PMMA의 표면 거칠기는 17.3$\sim$26.1 nm로 현저하게 높았음을 확인할 수 있었다.