• Title/Summary/Keyword: vacA

Search Result 179, Processing Time 0.022 seconds

A Study on the Development of a Variable Speed Diesel Generator for DC Distribution (직류배전용 가변속 디젤발전기 개발에 관한 연구)

  • Park, Kido;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 2019
  • In this study, research and a demonstration for applying DC distribution systems to ships as an environmental and energy conservation solution in domestic and foreign countries were actively carried out. In order to apply a generator to a DC distribution system, a variable speed engine was used. Both engine speed and fuel consumption were reduced. In this paper, a DC generator for DC distribution was constructed using a diesel generator, a generator controller, a governor, and an AVR. A system configuration method for a generator, power quality test, and the power characteristics of a variable speed generator were analyzed. The voltage (250 - 440 VAC) and frequency (34 - 60 Hz) of the variable speed generator were set to 60 - 100 % of the rated value, and the engine was set to operate from 1100 - 1800 rpm. It was confirmed that the voltage, current, and frequency of the generator output fluctuated in a stable manner according to the power amount when changing the engine speed of the generator according to the load variation.

A Study on Pendulum Generator Using Human Body Kinetic Energy (인체 운동 에너지를 이용한 진자 발전기에 관한 연구)

  • Jee, In-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.117-122
    • /
    • 2022
  • In this study, Electromagnetic Induction Power Generation (EMG) is a structure consisting of a stator and a permanent magnet rotor, and is a method that enables power generation by using the kinetic energy of the human arm. Among them, the axial flux permanent magnet (AFPM) technique is a method that can act sensitively to the kinetic energy of the arm at a slow speed of the human body, and has a simple structure and can be designed and manufactured with an ultra-small size. Under the conditions of size of ø46×11mm, rotation speed of 7Hz (420rpm), output voltage 0.4VAC, output current 4.5mA, and output power 30mW were measured and analyzed the same as the target specification. Therefore, the purpose of this study is to study the power generation of the pendulum applying the AFPM (Axial Flux Permanent Magnet) technique to charge power to smart devices with kinetic energy of the human body.

Postoperative orocutaneous fistula closure using a vacuum-assisted closure system: a case report (구강암 수술 후 발생한 구강 경부 누공(orocutaneous fistula) 치료 시 진공 음압 폐쇄(vacuum-assisted closure) 시스템을 이용한 상처 치료)

  • Lee, Seung-June;Kwon, Jin-Il;Lim, Kyung-Min;Kim, Hyung-Jun;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.413-416
    • /
    • 2010
  • Fleischmann et al. first described the concept of using sub-atmospheric pressure to treat open or infected wounds in 1993. Since then, Argenta and Morykwas developed subatmospheric, or negative pressure dressings in 1997 as a means of managing complicated wounds. Since its introduction in 1997, the vacuum-assisted closure (VAC) system has been used widely in general plastic surgery, general surgery, and orthopedic surgery to manage complicated wounds of the torso and extremities. However, there is a paucity of literature describing its use in the head and neck region, particularly in oral and maxillofacial surgery. We report a successful case of postoperative orocutaneous fistula closure using a VAC system in a 59-year male with a review of the relevant literature.

Bladder Recovery Patterns in Patients with Complete Cauda Equina Syndrome: A Single-Center Study

  • Reddy, Ashok Pedabelle;Mahajan, Rajat;Rustagi, Tarush;Chhabra, Harvinder Singh
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.981-986
    • /
    • 2018
  • Study Design: Retrospective case series. Purpose: Cauda equina syndrome (CES) is associated with etiologies such as lumbar disc herniation (LDH) and lumbar canal stenosis (LCS). CES has a prevalence of 2% among patients with LDH and exhibits variable outcomes, even with early surgery. Few studies have explored the factors influencing the prognosis in terms of bladder function. Therefore, we aimed to assess the factors contributing to bladder recovery and propose a simplified bladder recovery classification. Overview of Literature: Few reports have described the prognostic clinical factors for bladder recovery following CES. Moreover, limited data are available regarding a meaningful bladder recovery status classification useful in clinical settings. Methods: A single-center retrospective study was conducted (April 2012 to April 2015). Patients with CES secondary to LDH or LCS were included. The retrieved data were evaluated for variables such as demographics, symptom duration, neurological symptoms, bladder symptoms, and surgery duration. The variable bladder function outcome during discharge and at follow-up was recorded. All subjects were followed up for at least 2 years. A simplified bladder recovery classification was proposed. Statistical analyses were performed to study the correlation between patient variables and bladder function outcome. Results: Overall, 39 patients were included in the study. Majority of the subjects were males (79.8%) with an average age of 44.4 years. CES secondary to LDH was most commonly seen (89.7%). Perianal sensation (PAS) showed a significant correlation with neurological recovery. In the absence of PAS, bladder function did not recover. Voluntary anal contraction (VAC) was affected in all study subjects. Conclusions: Intactness of PAS was the only significant prognostic variable. Decreased or absent VAC was the most sensitive diagnostic marker of CES. We also proposed a simplified bladder recovery classification for recovery prognosis.

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

A Study on Local Standard Complement Between the LED Signal Head and Traffic Controller for Improving Signal Safety (신호의 안전성 향상을 위한 교통신호기와 LED신호등의 연계 특성 개선 방안 연구)

  • Le, Choul-Ki;Lee, Jeong-Jun;Oh, Bong-Sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • The off-state impedance of LED signal head is greater than that of a traditional bulb signal head, and the traffic controller has inherent off-state output leakage current. These two characteristics make the field trouble and reduce signal safety when the LED signal head is installed with traffic controller. In this Paper, a complement method of the LED signal head and traffic controller local standard (220vac line voltage) for improving signal safety is suggested. The point of designed complement method is to reduce the output leakage current of the traffic controller under 3mA, to increase the voltage feedback threshold to $70{\pm}5V$, and to make LED signal head maintain off-state in 0-95vac with 10Kohm maximum impedance.

  • PDF

Investigation of Helicobacter pylori cagE Locus Diversity on Interleukin-8 Induction in AGS Cell-line (Helicobacter pylori cagE 유전자 다형성이 위상피세포주에서 Interleukin-8 유도능에 미치는 영향)

  • Lee Su-Min;Lee Hak-Sung;Lee In-Suk;Co Yu-Kyung;Han Hae-Won;Oh Jung-Hwan;Park Jae-Myung;Choi Myung-Gyu;Chung In-Sik
    • Journal of Life Science
    • /
    • v.14 no.6 s.67
    • /
    • pp.906-912
    • /
    • 2004
  • Helicobacter pylori infection is highly prevalent, as high as 2/3 of whole population infected, in Korea. H. pylori infection initiates inflammation by induction of interleukin-8 through type IV secretion of CagA. It was recently suggested that induction failure of IL-8 is not associated with defect in cag PAI but associated with cagE locus diversity. This study was designed to investigate ability of 11-8 in-duction according to sequence variation within the cagE gene, cagA TP motifs and vacA m-types in vitro study using AGS cell-line, and to evaluate its association with different clinical outcome. Seventy-four H. pylori stains were isolated from 23 patients with gastric cancer (Ca), 24 subjects with gastritis (G) and 27 patients with duodenal ulcer (Du) in Kangnam St. Mary's Hospital, Seoul, Korea. cagE gene diversity was confirmed by the PCR-RFLP methods with MboI/NlaIII and tyrosine phosphate motifs (TPMs) of cagA was determined TPM-A and C by using DdeI/Tsp5091 restriction enzyme and TPM-B was determend by Real time PCR the method of Owen et al. and IL-8 was measured by ELISA assay. IL-8 activity was positively detected in 59 among 74 strains $(79.7\%)$. IL-8 secretion was significantly increased in MboI A and MboI B type compared to MboI C type and in MboI/NlaIII A-C and B-C type than C-C type. 1L-8 activity was not associated with either the number or composition of cagA tyrosine phosphorylation motifs and vacA m-type. There was no significant difference in IL-8 activity among patient groups. cagE gene diversity is thought to be mainly associated with the induction of IL-8 in H. pylori infection.

A Design of Power Converter for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환 회로 설계)

  • Won, Chung-Yuen;Jang, Su-Jin;Lee, Won-Chul;Lee, Tae-Won;Kim, Soo-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.61-68
    • /
    • 2004
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell is characterized by low voltage and high current. Therefor, for connecting to general load, it needs both a step up converter and an inverter. The proposed system consists of an isolated DC-DC converter to boost the fuel cell voltage to 380[Vdc] and a PWM inverter with LC filter to convert the dc voltage to single phase 220[Vac]. Also, bi-directional DC-DC converter for fuel cell generation system is composed to improve load response characteristic. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experiment verify that fuel cell generation system could be applied for the distributed generation.

Emulsion Polymerization of Vinyl acetate-Butyl acrylate Copolymer (유화 중합에 의한 비닐 아세테이트-부틸 아크릴레이트 공중합체의 합성 연구)

  • 설수덕;임종민
    • Polymer(Korea)
    • /
    • v.28 no.2
    • /
    • pp.135-142
    • /
    • 2004
  • Poly(vinyl acetate) (PVAc) prepared by emulsion polymerization has broad applications for additives such as paint binder, adhesive for wood and paper due to its low glass transition temperature which help to plasticize substrate resins. Since emulsion polymerization has a disadvantage that surfactant and ionic initiator degrade properties of the product polymer, poly(vinyl acetate-co-butyl acrylate) (VVc-BA) was synthesized using potassium persulfate as catalyst and poly(vinyl alcohol) (PVA) as protective colloid to prevent the degradation. The copolymer latex product was internally plasticized and has enhanced colloid stability, adhesion, tensile strength and elongation. During VAc-BA emulsion polymerization, no coagulation and complete conversion occur with the reactant mixture of 0.7wt% potassium persulfate, 15wt% poly(vinyl alcohol) (PVA-217), and the balanced monomer that the weight ratio of vinyl acetate to butyl acrylate is 19. As the concentrations of PVA increase, the copolymerization becomes faster and polymer particles are more stable, resulting in enhanced mechanical stability of the VAc-BA copolymer. However, the size of the polymer particles decreases with increasing PVA contents. Properties of the VAc-BA copolymer, such as minimum film formation temperature, glass transition temperature, surface morphology, molecular weight and molecular weight distribution, tensile strength and elongation, were characterized using differential scanning calorimeter, transmission electron microscope and other instruments.

Paratesticular Alveolar Rhabdomyosarcoma with Multiple Lymph Nodes Metastasis Successfully Treated with Chemotherapy (전이성 고환주위 폐포성 횡문근육종 1예)

  • Lee, Ha-Young;Hyun, Myung-Soo;Lee, Kyung-Hee;Kim, Min-Kyoung;Koh, Sung-Ae;Sohn, Se-Hoon;Park, Sung-Woo;Kim, Dong-Geun;Kim, Myung-Jin;Jang, Hyo-Jin;Kim, Mi-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.28 no.1
    • /
    • pp.70-76
    • /
    • 2011
  • Rhabdomyosarcomas are soft tissue sarcomas; while extremely rare in adults, they are one of the most common neoplasms in children and adolescents. Histologically, they can be classified into embryonal (ERMS), alveolar (ARMS), pleomorphic, and undifferentiated types. The ARMS type is very rare, and is associated with a poor prognosis. Common primary sites of ARMS are the trunk and extremities. We report on a case of paraaortic, supraclavicular, and axillary lymph node metastasis from paratesticular ARMS treated with VAC (vincristine, dactinomycin, cyclophosphamide)/ IE(ifosfamide, etoposide) chemotherapy in a young adult. Administration of six cycles of chemotherapy with VAC/IE resulted in complete remission. The patient has maintained complete remission over the past 27 months.

  • PDF