• Title/Summary/Keyword: v-ray

Search Result 2,499, Processing Time 0.027 seconds

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target (이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사)

  • Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.107-114
    • /
    • 2023
  • X-ray fluorescence analysis has been widely used in the field of science and industry because it gives information about elements and their concentrations without destruction of samples. To increase analysis accuracy of fluorescence generated by photons of the transmission-type X-ray tube for mixture and compound samples would be recommend to have strong energy near 10 keV and 20 keV simultaneously. Tungsten of 9.65 keV and molybdenum of 17.48 keV were considered as targets with dual deposition structure for obtaining two strong characteristic X-rays, and the transmission-type X-ray tube was analyzed using Geant4 Monte Carlo simulation. The W-Mo structure resulted in strong characteristic X-ray near 10 keV and 20 keV simultaneously. A structure with Mo-W multilayers of 5 ㎛ thick also gave optimal spectrum. Various material combination and thickness optimization for the dual-structured target can give X-ray spectrum with strong characteristic X-ray of specific energies.

Development and Characteristics of the Soft x-ray transmission W-target tube (W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • The x-ray transmission W-target tube was developed and its characteristics were evaluated. The continuous x-ray was emitted at the tube voltage less than 12kV, and the characteristic x-ray was emitted more than 12kV. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results are a good agreement with the blown ones. Moreover, in comparison with commercial x-ray tube, it was also found that the characteristics of our x-ray tube is better than the commercial one. Therefore we confirmed that the x-ray tube developed in this study is so good that it can be commercialized.

THE TeV GAMMA-RAY MILKY WAY

  • ROWELL, GAVIN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.553-557
    • /
    • 2015
  • This review summarises the current status of the Galactic TeV ($10^{12}$ eV) gamma-ray source population. It also briefly looks at the future beyond the current generation of TeV gamma-ray facilities, and highlights the role of the interstellar medium (ISM) in helping to resolve some of the challenges in interpreting the wealth of results which have been found in recent years.

Novel bricks based lightweight Vietnam's white clay minerals for gamma ray shielding purposes: An extensive experimental study

  • Ta Van Thuong;O.L. Tashlykov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.666-672
    • /
    • 2024
  • In the present work, a new brick series based on the Vietnamese white clay minerals from the Bat Trang was fabricated to be applied in the radiation protection applications during the decommissioning of the nuclear power reactors. The bricks were constructed under various pressure rates varied from 7.61 MPa to 114.22 MPa. The influence of pressure rate on the physical and γ-ray shielding properties were investigated in the study. The experimental measurement for the material's density using the MH-300A density meter showed an enhancement in the prepared bricks' density by 22.5 % with increasing the applied pressure rate while the bricks' porosity reduced by 31.2 % when the pressure rate increased from 7.61 MPa to 114.22 MPa. The increase in the fabricated bricks density and the reduction in their porosities enhances the bricks' linear attenuation coefficients as measured by the NaI (Tl) detector along the energy range extended from 0.662 MeV to 1.332 MeV. The linear attenuation coefficient increased by 13.8 %, 17.6 %, 17.0 %, and 17.1 % at gamma ray energies of 0.662 MeV, 1.173 MeV, 1.252 MeV, and 1.332 MeV, respectively. The enhancement in the linear attenuation coefficient increases the bricks' radiation protection efficiency by 10.22 %, 14.48 %, 14.09 %, and 14.26 % at gamma ray energies of 0.662 MeV, 1.173 MeV, 1.252 MeV, and 1.332 MeV, respectively.

A Study of Gamma-ray Distribution around the $^{99}Mo-^{99m}TcO_4$ Generator ($^{99}Mo-^{99m}TcO_4$ Generator의 감마선량 분포에 관한 연구)

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • A number of radionuclides of interest in nuclear medicine are short lived isotopes that emit only gamma ray. The most of all Dept. of Nuclear Medicine in the hospt. are using the $^{99}Mo-^{99m}Tc$ generator for elution of the short lived isotope $^{99m}TcO_4$. A $^{99}Mo-^{99m}Tc$ generator consists of an alumina column on which $^{99}Mo$ is bound. The parent isotope($^{99}Mo$ : half life 67 hr.) decays to its daughter $^{99m}TcO_4^-$ which is a different element with a shorter half-life. $^{99}Mo$ emitted 41-keV(1.3%), 141-keV(5.6%) 181-keV(6.6%) and 366-keV(1.5%) gamma rays. But $^{99m}TcO_4$ emitted only 140-keV gamma ray. We study about the gamma ray distribution around the $^{99}Mo$ generator. And obtained the result as follows ; 1. Total counted gamma ray from generator smaller in front side than back. 2. The gamma ray emitted from $^{99}Mo$ generator without $^{99m}TcO_4$ vial increased in the back side(Mo column posited side) 3. The gamma ray only from the $^{99m}TcO_4$ vial increased in the front side. 4. Apron can protect gamma ray above 60% of total radiation from the $^{99}Mo$ generator.

  • PDF

Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube (40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.247-252
    • /
    • 2008
  • By using the transmission anode x-ray tube developed to apply to the hand-held XRF equipment, we carried out XRF experiment and evaluated the influences of the x-ray tube on XRF spectra. XRF data, which is measured using the W-target and Rh-target tube, were good agreements with the known results. FWHM of Fe $K_{\alpha}$-line measured by W-target tube with the 35 kV-tube voltage and the $40{\mu}A$-tube current was 180 eV. This result reveals that our XRF equipment using the transmission anode x-ray tube is enough for a qualitative analysis of materials. By comparison XRF data with the integrated intensity of x-ray tube, it was confirmed that Rh-target tube is better than W-target tube for application to the hand-held XRF equipment.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Microlens Micro V-groove Fabrication by the Modified LIGA Process (변형 DEEP X-ray를 이용한 마이크로 렌즈 및 V-groove 제작)

  • 이정아;이승섭;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.290-295
    • /
    • 2004
  • Mircolens and microlens V-groove are realized using a novel fabrication technology based on the exposure of a resist, usually PMMA, to deep X-rays and subsequent thermal treatment and inclined deep X-ray lithography, respectively. The fabrication technology is very simple and produces microlenses and microlens V-groove with good surface roughness of several nm. The molecular weight and glass transition temperature of PMMA is reduced when it is irradiated with deep X-rays. The microlenses were produced through the effects of volume change, surface tension, and reflow during thermal treatment of irradiated PMMA. Microlenses were produced with diameters ranging from 30 to $1500\mu\textrm{m}$. The surface X-ray mask is also fabricated to realize microlens arrays on PMMA sheet with a large area. The size of the micro V-groove is fabricated in the range of 12~$60\mu\textrm{m}$.

A Study on the Optimal Make of X-ray Ionizer using the Monte Carlo N-Particle Extended Code(II) (Monte Carlo N-Particle Extended Code를 이용한 연 X선 정전기제거장치의 최적제작에 관한 연구(II))

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.29-33
    • /
    • 2017
  • In order to solve this sort of electrostatic failure in Display and Semiconductor process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. There exist variable factors such as type of tungsten thickness deposited on target, Anode voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. Here, MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was compared according to target material thickness using MCNPX and actual X-ray tube source under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W). At the result, In Tube voltage 5 keV and distance 100 mm, optimal target thickness is $0.05{\mu}m$ and fastest decay time appears + decay time 0.28 sec. - deacy time 0.30 sec. In Tube voltage 10keV and distance 100 mm, optimal target Thickness is $0.16{\mu}m$ and fastest decay time appears + decay time 0.13 sec. - deacy time 0.12 sec. In the tube voltage 15 keV and distance 100 mm, optimal target Thickness is $0.28{\mu}m$ and fastest decay time appears + decay time 0.04 sec. - deacy time 0.05 sec.