• Title/Summary/Keyword: utility distribution

Search Result 371, Processing Time 0.03 seconds

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

A three-dimensional finite element analysis for initial stress of maxillary incisiors during activation of upper utility arch wire (Utility Arch Wire 적용시 상악 중절치 및 측절치의 초기 응력 분포에 관한 3차원 유한요소법적 연구)

  • Lee, Jong-hyun;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.411-424
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution of initial compressive and tensile stress when anterior section of upper utility arch was activated crown lingual torque of $5^{\circ},\;10^{\circ},\;15^{\circ}$ through three-dimensional finite element analysis. For this study the finite element model of upper central and lateral incisors, 1st. and 2nd. premolars and 1st. molars and each periodontal membrane and upper utility arch were made. From the solutions of ANSYS the followings were obtained. 1. $5^{\circ},\;10^{\circ},\;15^{\circ}$ crown lingual torque produce the almost similar distribution and measurement of initial compressive and tensile stress. 2. Acivated upper utility arch torqued central inciors lingually and lateral incisors labially.

  • PDF

A Study on the Detecting Accuracy of EM Induction Survey Data of Buried Utility (전자유도 탐사를 이용한 지하매설물 탐지 정확도 분석)

  • Kwon, Hyoung-Seok;Choi, Joonho;Hwang, Daejin;Kim, Munjae;Yoon, Jeoungseob
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.4
    • /
    • pp.73-81
    • /
    • 2008
  • Electromagnetic induction surveys are one of the useful methods to detect the location and buried depth of underground utilities by measuring horizontal and vertical magnetic fields. It can effectively detects single buried utility with the accuracy of within 20 cm. However when another utility is buried near to target one, the accuracy of utility location considerably decreases due to the distortion of magnetic fields caused from adjacent utility. This study shows the ways to verify the location and buried depth of target utility when magnetic fields does not show symmetric distribution due to adjacent another utility. Using Bluetooth wireless communication tools, we developed the way to records measured magnetic fields to handheld PDA. We investigated the criteria for minimum distance of two adjacent utilities to separate the individual responses through field model test.

  • PDF

Making Utility-Integrated Energy Storage a Used, Useful and Universal Resource

  • Doosan GridTech
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Objective signs are everywhere that the stationary energy storage market is growing up quickly. The use of distributed resources such as solar photovoltaics and electric vehicles are expanding at a rapid pace, creating technical challenges for the distribution system that will require energy storage and a new generation of software to address. This paper is intended for distribution utility managers and executives and makes the following points: ${\bullet}$ Utility-integrated (as opposed to merely grid-connected) energy storage projects represent a distinct, new wave of industry growth that is just getting underway and is required to manage distributed energy resources moving forward. ${\bullet}$ Utilities and the energy storage industry have important roles to lower risk in adopting this technology - thereby enabling this wave of growth. ${\circ}$ The industry must focus on engineering energy storage for adoption at scale - including the creation and support of software open standards -both to drive down costs and to limit technology and supplier risk for utilities. ${\circ}$ Utilities need to take a program-based, rather than a project- based, approach to this resource to best balance cost and risk as they procure and implement energy storage. By working together to drive down costs and manage risk, utilities and their suppliers can lay the energy storage foundation for a new, more digital distributed electricity system.

A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser (리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘)

  • Kim, Seul-Ki;Kim, Eung-Sang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.5
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

A Study on the Simulation Model of PV Generation System for its Application to Real Power System (계통 연계형 태양광 발전 시스템의 실계통 적용을 위한 시뮬레이션 모델에 관한 연구)

  • Lee, Kye-Byung;Son, Kwang-Myung;Jeon, In-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.70-78
    • /
    • 2008
  • This paper deals with the simulation modeling of PV generation system for its application to utility distribution network PSCAD/EMIDC simulation model is developed for use in studying the effect of the PV generation to the distribution system. Simulation results show that the addition of the PV system improves the voltage profile of the area by decreasing the power flow from the utility substation. Case studies also show that power quality at the load side is also improved via voltage compensation at the load bus.

Multiattribute Stochastic Statistical Dominance in Decision Making with Incomplete Information (불완전한 정보하의 의사결정하에서의 아중요인 추계적-통계적 우세법칙)

  • 이대주
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.18 no.2
    • /
    • pp.45-55
    • /
    • 1993
  • In multiattribute decision making a decision maker (DM) can choose the best alternative if his/her multiattribute utility function and the joint probability distribution of outcomes are exactly known. This paper develops multiattribute stochastic-statistical dominance rules which can be applied to the situation when neither of them is known exactly, that is, when the DM cannot calculate the expected utility for each alternative. First, the notion of relative risk aversion is used dominance rules are developed to screen out dominated alternatives so that hi/she choose the best one among the remaining nondominated alternatives.

  • PDF

An Investigation into the Impact on Voltage Sag due to Faults in Low Voltage Power Distribution Systems

  • Aggarwal R. K.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.97-102
    • /
    • 2005
  • Voltage sags are the most widespread quality issues affecting distribution systems. This paper describes in some detail the voltage sag characteristics due to different types and locations of fault in a practical low voltage power distribution system encountered in the UK. The results not only give utility engineers very useful information when identifying parts of the system most likely to pose problems for customer equipments, but also assist the facility personnel to make decisions on purchasing power quality mitigation equipment.

The study of technical trend of Chinese distribution automation (중국의 배전자동화 기술동향 분석)

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jung, Mi-Ae;Shin, Ick-Su;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.430-432
    • /
    • 2003
  • We want to know the specification of Chinese distribution automation system and facilities for approach to Chinese market. This paper introduces the purpose of distribution automation project, function of distribution automation system, standard of facilities by specification of utility in China.

  • PDF

A Study of the Optimal Condenser Operation in Distribution System (배전선로의 적정 콘덴서 운용 연구)

  • Jeon, Young-Soo;Jang, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1238-1240
    • /
    • 1998
  • For economic operating of distribution system, utility has to minimize the loss in distribution line by controlling reactive power and power factor. This paper presents calculation of reactive power in distribution line, estimation of the condenser capacity according to distance, and computation of optimal location and proper condenser capacity.

  • PDF