• Title/Summary/Keyword: utility detection

Search Result 222, Processing Time 0.03 seconds

Detection of Complex Event Patterns over Interval-based Events (기간기반 복합 이벤트 패턴 검출)

  • Kang, Man-Mo;Park, Sang-Mu;Kim, Sank-Rak;Kim, Kang-Hyun;Lee, Dong-Hyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.201-209
    • /
    • 2012
  • The point-based complex event processing handled an instantaneous event by using one time stamp in each event. However, the activity period of the event plays the important role in the field which is the same as the finance, multimedia, medicine, and meteorology. The point-based event is insufficient for expressing the complex temporal relationship in this field. In the application field of the real-time world, the event has the period. The events more than two kinds can be temporally overlapped. In addition, one event can include the other event. The relation about the events of kind of these can not be successive like the point-based event. This thesis designs and implements the method detecting the patterns of the complex event by using the interval-based events. The interval-based events can express the overlapping relation between events. Furthermore, it can include the others. By using the end point of beginning and end point of the termination, the operator of interval-based events shows the interval-based events. It expresses the sequence of the interval-based events and can detect the complex event patterns. This thesis proposes the algorithm using the active instance stack in order to raise efficiency of detection of the complex event patterns. When comprising the event sequence, this thesis applies the window push down technique in order to reduce the number of intermediate results. It raises the utility factor of the running time and memory.

The Role Of Tumor Marker CA 15-3 in Detection of Breast Cancer Relapse After Curative Mastectomy (유방암 환자에서 근치적 유방 절제술 후 재발 발견에 대한 CA 15-3의 역할)

  • Hyun, In-Young;Kim, In-Ho;Lee, Moon-Hee;Kim, Chul-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • Purpose: The purpose of this study was to determine the utility of tumor marker CA 15-3 in the following: the diagnosis of breast cancer relapse after curative mastectomy, and the differentiation or the value of tumor marker by site of metastases. Materials and Methods: Two hundred two patients (median age 48 years) with breast cancer included in the follow-up after curative mastectomy. The tumor marker CA 15-3 was determined by IRMA (CIS BIO INTERNATIONAL, France). Test values > 30 U/ml were considered elevated (positive). Results: Among 202 patients, recurrent diseases were found in 16 patients. CA 15-3 was elevated in 5 of 16 patients with recurrences. There was no false-positive patient who had elevated CA 15-3. Sensitivity and specificity of CA 15-3 for detection of breast cancer recurrence were 31%, and 100%. CA 15-3 was elevated in all of the 4 patients with liver metastases. CA 15-3 was elevated in none of the patients who relapsed with metastasis to bone-only or contralateral breast-only. Conclusion: The tumor marker CA 15-3 in the detection of breast cancer relapse after curative mastectomy is specific, but not sensitive. However, it is useful to rule out liver metastases of breast cancer, which indicates bad prognosis.

Automatic Detection of Usability Issues on Mobile Applications (모바일 앱에서의 사용자 행동 모델 기반 GUI 사용성 저해요소 검출 기법)

  • Ma, Kyeong Wook;Park, Sooyong;Park, Soojin
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.7
    • /
    • pp.319-326
    • /
    • 2016
  • Given the attributes of mobile apps that shorten the time to make purchase decisions while enabling easy purchase cancellations, usability can be regarded to be a highly prioritized quality attribute among the diverse quality attributes that must be provided by mobile apps. With that backdrop, mobile app developers have been making great effort to minimize usability hampering elements that degrade the merchantability of apps in many ways. Most elements that hamper the convenience in use of mobile apps stem from those potential errors that occur when GUIs are designed. In our previous study, we have proposed a technique to analyze the usability of mobile apps using user behavior logs. We proposes a technique to detect usability hampering elements lying dormant in mobile apps' GUI models by expressing user behavior logs with finite state models, combining user behavior models extracted from multiple users, and comparing the combined user behavior model with the expected behavior model on which the designer's intention is reflected. In addition, to reduce the burden of the repeated test operations that have been conducted by existing developers to detect usability errors, the present paper also proposes a mobile usability error detection automation tool that enables automatic application of the proposed technique. The utility of the proposed technique and tool is being discussed through comparison between the GUI issue reports presented by actual open source app developers and the symptoms detected by the proposed technique.

Evaluation of Geospatial Information Construction Characteristics and Usability According to Type and Sensor of Unmanned Aerial Vehicle (무인항공기 종류 및 센서에 따른 공간정보 구축의 활용성 평가)

  • Chang, Si Hoon;Yun, Hee Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.555-562
    • /
    • 2021
  • Recently, in the field of geospatial information construction, unmanned aerial vehicles have been increasingly used because they enable rapid data acquisition and utilization. In this study, photogrammetry was performed using fixed-wing, rotary-wing, and VTOL (Vertical Take-Off and Landing) unmanned aerial vehicles, and geospatial information was constructed using two types of unmanned aerial vehicle LiDAR (Light Detection And Ranging) sensors. In addition, the accuracy was evaluated to present the utility of spatial information constructed through unmanned aerial photogrammetry and LiDAR. As a result of the accuracy evaluation, the orthographic image constructed through unmanned aerial photogrammetry showed accuracy within 2 cm. Considering that the GSD (Ground Sample Distance) of the constructed orthographic image is about 2 cm, the accuracy of the unmanned aerial photogrammetry results is judged to be within the GSD. The spatial information constructed through the unmanned aerial vehicle LiDAR showed accuracy within 6 cm in the height direction, and data on the ground was obtained in the vegetation area. DEM (Digital Elevation Model) using LiDAR data will be able to be used in various ways, such as construction work, urban planning, disaster prevention, and topographic analysis.

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF

Investigation of the Molecular Diagnostic Market in Animals (동물 분자 진단 시장의 동향)

  • Park, Chang-Eun;Park, Sung-Ha
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.26-33
    • /
    • 2019
  • Recently, the rapid growth of the companion animal market has led to the development of animal disease diagnosis kits. Therefore, the utility of the introduction of biomarkers for the development of animal molecular diagnostics is being reevaluated. A good biomarker should be precise and reliable, distinguish between normal and diseased states, and differentiate between different diseases. Recently reported genetic markers, tumor markers (cell free DNA, circulating tumor cells, granzyme, and skin tumors), and others (brucellosis, programmed death recovery-1, symmetric dimethylarginine, periostin, and cysteinyl leukotrien) have been developed. The biomarkers are used for risk prediction or for the screening, diagnosis, and monitoring of disease progression. The most important criteria for related biomarkers are disease specificity. Many potential biomarkers have emerged from laboratory and test studies, but they have not been validated in independent or large-scale clinical studies. Candidate biomarkers evaluate disease associations, verify the effectiveness of biomarkers for early detection and disease progression, and incorporate them into humans and animals. In the future, it will be necessary to reevaluate the utility of well-structured biomarker-based research and study the development of kits that can be used in on-site tests in accordance with the trends introduced in the diagnosis of animal diseases.

Quality Evaluation through Inter-Comparison of Satellite Cloud Detection Products in East Asia (동아시아 지역의 위성 구름탐지 산출물 상호 비교를 통한 품질 평가)

  • Byeon, Yugyeong;Choi, Sungwon;Jin, Donghyun;Seong, Noh-hun;Jung, Daeseong;Sim, Suyoung;Woo, Jongho;Jeon, Uujin;Han, Kyung-soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1829-1836
    • /
    • 2021
  • Cloud detection means determining the presence or absence of clouds in a pixel in a satellite image, and acts as an important factor affecting the utility and accuracy of the satellite image. In this study, among the satellites of various advanced organizations that provide cloud detection data, we intend to perform quantitative and qualitative comparative analysis on the difference between the cloud detection data of GK-2A/AMI, Terra/MODIS, and Suomi-NPP/VIIRS. As a result of quantitative comparison, the Proportion Correct (PC) index values in January were 74.16% for GK-2A & MODIS, 75.39% for GK-2A & VIIRS, and 87.35% for GK-2A & MODIS in April, and GK-2A & VIIRS showed that 87.71% of clouds were detected in April compared to January without much difference by satellite. As for the qualitative comparison results, when compared with RGB images, it was confirmed that the results corresponding to April rather than January detected clouds better than the previous quantitative results. However, if thin clouds or snow cover exist, each satellite were some differences in the cloud detection results.

Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base

  • Norouzi, Parviz;Ganjali, Mohammad Reza;Faridbod, Farnoush;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1439-1444
    • /
    • 2006
  • A $Cu^{2+}$ ion-selective membrane microelectrode has been fabricated from poly vinyl chloride (PVC) matrix membrane containing a new symmetrical hexadentate Schiff,s base 2-{1-(E)-2-((Z)-2-{(E)-2-[(Z)-1-(2-hydroxyphenyl)ethylidene]hydrazono}-1-methylpropylidene)hydrazono]ethyl}phenol (HDNOS) as a neutral carrier, Potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic excluder and o-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The microelectrode displays linear potential response in the concentration range of $1.0\;{\times}\;10^{-5}-1.0\;{\times}\;10^{-11}$ M of $Cu^{2+}$. The microelectrode exhibits a nice Nernstian slope of 25.9 ${\pm}$ 0.3 mV $decade^{-1}$ in the pH range of 3.1-8.1. The sensor has a relatively short response time in whole concentration ranges ($\sim$5 s). The detection limit of proposed sensor is $5.0\;{\times}\;10^{-12}$ M (320 pg/L), and it can be used over a period of eight weeks. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of $Cu^{2+}$ with EDTA. The proposed membrane electrode was used for the direct determining of $Cu^{2+}$ content in black and red pepper, and in waste water samples.

p16INK4a is a Useful Marker of Human Papillomavirus Integration Allowing Risk Stratification for Cervical Malignancies

  • Cheah, Phaik-Leng;Looi, Lai-Meng;Teoh, Kean-Hooi;Mun, Kein-Seong;Nazarina, Abdul Rahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.2
    • /
    • pp.469-472
    • /
    • 2012
  • The present study was conducted to assess utility of $p16^{INK4a}$ immunopositivity as a surrogate marker for genomic integration of high-risk human papillomavirus infection (hrHPV). A total of 29 formalin-fixed, paraffin-embedded cervical low-grade squamous intraepithelial lesions (LSILs), 27 high-grade squamous intraepithelial lesions (HSILs) and 53 invasive squamous cell carcinomas (SCCs), histologically-diagnosed between 1st January 2006 to 31st December 2008 at the University of Malaya Medical Centre were stained for $p^{16INK4a}$ (CINtec Histology Kit (REF 9511, mtm laboratories AG, Heidelberg, Germany). Immunopositvity was defined as diffuse staining of the squamous cell cytoplasm and or nucleus (involving > 75% of the intraepithelial lesions or SCCs). Staining of basal and parabasal layers of intraepithelial lesions was pre-requisite. One (3.4%) LSIL, 24 (88.9%) HSIL and 46 (86.8%) SCC were $p^{16INK4a}$ immunopositive. All normal squamous epithelium did not express $p16^{INK4a}$. $p16^{INK4a}$ expression was significantly lower (p<0.05) in LSIL compared with HSIL and SCC with no difference in expression between HSIL and SCC. The increased $p16^{INK4a}$ immunopositivity in HSIL and SCC appears in line with the integrated existence of the hrHPV and may provide more insightful information on risk of malignant transformation of cervical squamous intraepithelial lesions than mere hrHPV detection.

Findings of an Intravenous Catheter Fragment in the Vein Using the 3D Image Reformations of MDCT (정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Yang, Sung-Hwan;Kim, Jeong-Goo
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2006
  • Catheter fragment and embolism are both potentially serious complications associated with the use of an intravenous (IV) catheter for contrast media bolus injection, and may be followed by serious or lethal sequelae. Though catheter fragment is a rare complication of IV catheter insertion, especially in peripheral veins, CT can be used to detect residual fragment. This study demonstrates the utility of MDCT to localize a small, subtle peripheral venous catheter, which can be easily reformatted of MDCT reformations. Various 3D techniques such as MPR and MIP, volume rendering, and shaded-surface displays are currently available for reconstructing MDCT data. Advances in MDCT technology contribute substantially to the detection and accurate localization of smaller IV catheter fragment.

  • PDF