• Title/Summary/Keyword: use evaluation

Search Result 8,925, Processing Time 0.033 seconds

Acute Ecotoxicity Evaluation of 3 Emulsifiable Concentrates Containing Garlic Extract, Zanthoxylum Extract, and Lemon Grass Oil Originated from Plant (식물추출물 마늘 추출액, 잔톡실럼 정유, 레몬그라스 정유 함유 유제 3종의 생태독성평가)

  • You, Are-Sun;Hong, Soon-Sung;Jeong, Mihye;Park, Kyung-Hun;Chang, Hee-Seop;Lee, Je Bong;Park, Jae-Yup
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.376-382
    • /
    • 2012
  • Environment-friendly agro-materials are are likely to be preferred to chemical insecticides recently. For this reason, many studies are conducted to develop environment-friendly insecticides containing natural materials. This study was also conducted so as to assess ecotoxicity for Emulsifiable concentrate (EC) containing 30% of garlic extract or two plant essential oils (Zanthoxylum, Lemongrass) expected to prevent from pests and be used for agro-materials. Target species used to assess acute toxicity were invertebrate (Daphina magna), fish (Oryzias latipes), honeybee (Apis mellifera L.) and earthworm (Eisenia fetida). The $EC_{50}$ values for of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC to Daphina magna were 3.3, 10, and $10mg\;L^{-1}$, respectively. The category of garlic extract 30% EC was moderately toxic, while those of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were slightly toxic according to standard of USEPA. $EC_{50}$ for both of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than $10mg\;L^{-1}$ then they were considered as slightly toxicity. In case of acute toxicity test to fish, $LC_{50}$ of garlic extract 30% EC was $3.3mg\;L^{-1}$. Zanthoxylum oil 30% EC and lemongrass oil 30% EC indicated $LC_{50}$ > $10mg\;L^{-1}$. Classification of acute toxicity to all test substances was in Korea criteria. Acute contact and oral toxicity test to Honeybee were conducted. As a result, $LD_{50}$ of all test substances were more than 100 a.i. ${\mu}g\;bee^{-1}$ in the acute contact test while $LD_{50}$ of garlic extract 30% EC was 4.4 a.i. ${\mu}g\;bee^{-1}$ and $LD_{50}$ of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than 100 a.i. ${\mu}g\;bee^{-1}$. In case of acute toxicity test to earthworm, $LC_{50}$ of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC were 267, 592, and $430mg\;kg^{-1}$, respectively. In conclusion, if the safety for earthworm is confirmed, these substances are expected to be use for environment-friendly insecticide materials with low risk against ecosystem and contribute to developing environment-friendly agro-materials.

Research on Science, Technology & Society in Korea: A Critical Review (과학기술과 사회 연구의 현황과 과제)

  • Bak, Hee-Je
    • Journal of Technology Innovation
    • /
    • v.25 no.3
    • /
    • pp.155-195
    • /
    • 2017
  • The goal of the present study is reviewing the literature on the scientific community and also on science, technology & society to increase interactions between innovation studies and social studies of science and technology. Up until now, various empirical studies on Korean scientists and engineers have been concentrated on researchers at universities, while they have paid inadequate attention to researchers at state-funded research institutes and private companies. In addition, these studies have tended to use concepts in Western academia to elucidate Korean cases. On the other hand, recent empirical researches on the effects of the evaluation systems in universities, PBS system, and the network of school ties suggest that these topics may reveal the unique characteristics of Korean scientific community. Empirical studies on the scientific community have also shown that Korean research institutes and researchers who are in charge of innovation in Korea have demonstrated a tendency to conform to the government's guidance due to long experiences of state-led R&D and nationalism. Research on science, technology and society has viewed the participation of citizens in science and technology as a way toward science and technology democracy, and tended to have a strong practical orientation. However, there has been a relatively small amount of research on how citizen participation influences the direction and content of technological innovation. Also, although, from the viewpoint of technological innovation, how participation of citizens in science and technology can contribute to knowledge production and innovation is a critical issue, relatively small numbers of case studies on this subject have been conducted. Therefore, as the scholars who have emphasized the democracy of science and technology have actually experimented with various ways of citizen participation, innovation researchers may have to design and implement citizen participation through which citizens' local knowledge can contribute to technological innovation.

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Birth and Infant Death Reporting System via Computer Network (출생 및 영아사망 신고체계 및 전산정보체계 개발)

  • Park, Jung-Han;Lee, Young-Sook;Rhee, Jung-Ae;Cho, Hyun;Chung, Young-Hae;Park, Soon-Woo;Jun, Hae-Ri
    • Health Policy and Management
    • /
    • v.8 no.2
    • /
    • pp.125-148
    • /
    • 1998
  • Accurate vital statistics are essential for a national health planning and evaluation. Among various vital statistics, birth and death rates, and infant and matemal mortality rates together with the causes of death are the very basic ones for above purposes as well as for the maternal and child health management. These statistics are based on the birth and death reports. It is required by law to report every birth and death within one month after its occurrence. However, in case of a neonatal death occurring prior to the birth report, most of the birth and death are not reported. Thus accurate infant and maternal mortality rates are not available yet in Korea. The main objective of this study is to develop a birth and infant death reporting system via computer network. We designed a new birth report form based on the current form and data from the analysis of medical record forms of 14 hospitals. A new form is basically addition of essential medical information to the current birth report form. Since a revision of the rules and regulations related wtih the birth report is necessary to use a new form, we kept the current from intact to make it acceptable to the government office for a field trial. We also developed computer programs for data input for birth and death reports at a medical faciltiy, data processing for production of maternal and child health indices at a health center, and management of maternal and child health services including immunization and postantal care at health center. The birth certificate and birth report can be printed out at a medical facility. The computer packages were programmed by Borland Delphi 3.0 and can be run under Windows 95 system. We proposed a new birth and death reporting system via computer network after a field trial for data input, transmission, and processing. The medical and demographic data o birth and death at medical facilities will be sent to health centers directly via computer network. The health center will retain the medical data for analysis and forward only the data for birth and death reports required by current regulations to the Dong, Up, or Myun Office. Once the birth or death is reported via computer network to the Dong Office, then the Dong Office will notify the baby's mother of the birth report and request to submit the baby's name by mail. When the baby's name its submitted. the Dong Office will forward the birth reports to the Common Court and Statistics Agency in the same way as the current system, Upon the completion of birth registration of the Common Court, the court will issue the birth certificate to mother which will be used in lieu of the family record. The advantages of proposed birth and death reporting system via computer network ar as follows ; I) The accuracy, timing, and completeness of reporting will be improved and more accurate maternal and child health indices can be obtained, ii) The maternal and child health services of health center will be obtained, iii) Epidemiologic data for pregnancy and birth can be obtained, iv) Manpower for birth and death reporting will be saved.

  • PDF

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

Troposhperic Ozone Pollutions in Korea during 1998-2002 Using Two Ozone Indices for Vegetation Protection (식생보호를 위한 한계농도 누적 지표로 본 1998-2002년도의 우리나라 대기권 오존 오염)

  • 윤성철;김보선
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.1
    • /
    • pp.38-48
    • /
    • 2004
  • Tropospheric ozone data in Korea for 1998-2002 were analyzed to assess the impact on vegetation. SUM06(sum of hourly concentrations at or above 0.06 ppm) and AOT40(accumulated exposure over a threshold of 40 ppb), widely used as ozone indices in the U.S. and Europe, were calculated based on hourly ozone concentration in 612 areas during 1998-2002 in Korea. SUM06 of the highest 30 areas were 5-12 ppm/hr which were almost the same levels of the U.S. average, and a crop loss of 5% would be expected. Ozone pollution in Seoul during 1998-2002 had decreased compared to that for 1990-97 except in the Northern area; however, ozone pollution in Kyunggi during 1998-2002 had been increased twice compare to the previous 5 years. Korea was divided into four regions: Seoul Metropolitan area, Jungbu, Honam, and Youngnam. Ozone pollution in the Seoul Metropolitan area was much higher during 1998-2000 than the other areas, but ozone pollution during 2001-2002 was almost the same in all four regions. Chunnam-Kwangyang na Kyungbuk-Gumi, famous industrial complexes in southern Korea, were significant ozone pollution areas. However, other industrial complexes, such as Incheon, Ulsan, and Kyunggi-Sihwa, were not polluted compared to their neighbors. Comparing all ozone indices, SUM06(yr), SUM06(3mon), AOT40(yr), AOT40(3mon), number of hours exceeding 100 ppb, 95 percentile, 99 percentile, and maximum concentration, it was determined reasonable to use SUM06(3mon), AOT40(3mon) and number of hours exceeding 100 ppb for evaluation of the chronic impact of ozone on vegetation.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

Residual Characteristics of Bistrifluron and Chlorantraniliprole in Strawberry (Fragaria ananassa Duch.) for Establishing Pre-Harvest Residue Limit (생산단계 잔류허용기준 설정을 위한 딸기 중 bistrifluron과 chlorantraniliprole의 잔류 특성 연구)

  • Lee, Jae Won;Kim, Ji Yoon;Kim, Hee gon;Hur, Kyung Jin;Kwon, Chan Hyeok;Hur, Jang Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • BACKGROUND: Pesticide residue analysis is essentially required for safety evaluation of agricultural products. Bistrifluron and chlorantraniliprole have been currently considered as potentials to deeply evaluate their residues in agricultural products because they are frequently found in strawberry. This work was performed to investigate the residual patterns of bistrifluron and chlorantraniliprole in strawberry after harvest. METHODS AND RESULTS: Strawberry was treated with bistrifluron and chlorantraniliprole 0, 1, 2, 3, 5, 7 and 10 days before harvest under greenhouse conditions. The strawberry samples were subjected to solvent and solid phase extractions followed by LC-MS/MS analysis. There covery percentages of bistrifluron and chlorantraniliprole for tified in the control samples ranged from approximately 82 to 103% with the method limit of 0.005 mg/kg. The concentrations of bistrifluron and chlorantraniliprole in strawberry samples decreased significantly in 10 days after treatment, giving the safety levels of 0.04 to 0.06 mg/kg at 10 days after application, as considered maximum residue limit. The half-lives of bistrifluron and chlorantraniliprole based on first order kinetics were determined to 6.3 days and 6.4 days, respectively. CONCLUSION: Bistrifluron and chlorantraniliprole are suggested to use in strawberry 10 days before harvest to reach residual safety levels.